diff --git a/bricksrc/definitions.csv b/bricksrc/definitions.csv index 0ed996a5..0cadd8cb 100644 --- a/bricksrc/definitions.csv +++ b/bricksrc/definitions.csv @@ -46,7 +46,7 @@ https://brickschema.org/schema/Brick#Alarm,Alarm points are signals (either audi https://brickschema.org/schema/Brick#Alarm_Delay_Parameter,A parameter determining how long to delay an alarm after sufficient conditions have been met, https://brickschema.org/schema/Brick#Alarm_Sensitivity_Parameter,A parameter indicates the sensitivity to activate an alarm., https://brickschema.org/schema/Brick#Alternating_Current_Frequency,The frequency of the oscillations of alternating current, -https://brickschema.org/schema/Brick#Ammonia_Sensor,, +https://brickschema.org/schema/Brick#Ammonia_Sensor,Measures the concentration of ammonia in air, https://brickschema.org/schema/Brick#Angle_Sensor,Measues the planar angle of some phenomenon, https://brickschema.org/schema/Brick#Atrium,a large open-air or skylight covered space surrounded by a building.,https://en.wikipedia.org/wiki/Atrium_(architecture) https://brickschema.org/schema/Brick#Audio_Visual_Equipment,Equipment related to sound and visual components such as speakers and displays., @@ -252,8 +252,8 @@ https://brickschema.org/schema/Brick#Deceleration_Time_Setpoint,, https://brickschema.org/schema/Brick#Dedicated_Outdoor_Air_System_Unit,"A device that conditions and delivers 100% outdoor air to its assigned spaces. It decouples air-conditioning of the outdoor air, usually used to provide minimum outdoor air ventilation, from conditioning of the internal loads.", https://brickschema.org/schema/Brick#Dehumidification_Start_Stop_Status,, https://brickschema.org/schema/Brick#Dehumidify_Command,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels", -https://brickschema.org/schema/Brick#Deionised_Water_Conductivity_Sensor,Measures the electrical conductance of deionised water, -https://brickschema.org/schema/Brick#Deionised_Water_Level_Sensor,Measures the height/level of deionised water in some container, +https://brickschema.org/schema/Brick#Deionized_Water_Conductivity_Sensor,Measures the electrical conductance of deionized water, +https://brickschema.org/schema/Brick#Deionized_Water_Level_Sensor,Measures the height/level of deionized water in some container, https://brickschema.org/schema/Brick#Deionized_Water,Water which has been purified by removing its ions (constituting the majority of non-particulate contaminants), https://brickschema.org/schema/Brick#Deionized_Water_Alarm,An alarm that indicates deionized water leaks., https://brickschema.org/schema/Brick#Delay_Parameter,A parameter determining how long to delay a subsequent action to take place after a received signal, @@ -270,7 +270,7 @@ https://brickschema.org/schema/Brick#Differential_Pressure_Bypass_Valve,"A 2-way https://brickschema.org/schema/Brick#Differential_Pressure_Deadband_Setpoint,Sets the size of a deadband of differential pressure, https://brickschema.org/schema/Brick#Differential_Pressure_Integral_Time_Parameter,, https://brickschema.org/schema/Brick#Differential_Pressure_Load_Shed_Status,, -https://brickschema.org/schema/Brick#Differential_Pressure_Proportional_Band,, +https://brickschema.org/schema/Brick#Differential_Pressure_Proportional_Band_Parameter,, https://brickschema.org/schema/Brick#Differential_Pressure_Sensor,Measures the difference between two applied pressures, https://brickschema.org/schema/Brick#Differential_Pressure_Setpoint,Sets differential pressure, https://brickschema.org/schema/Brick#Differential_Pressure_Setpoint_Limit,, @@ -1065,6 +1065,7 @@ https://brickschema.org/schema/Brick#Smoke_Alarm,An alarm that indicates the off https://brickschema.org/schema/Brick#Smoke_Detection_Alarm,, https://brickschema.org/schema/Brick#Smoke_Detector,, https://brickschema.org/schema/Brick#Soil_Temperature_Sensor,Measures the temperature of soil, +https://brickschema.org/schema/Brick#Solar,Relating to the sun, https://brickschema.org/schema/Brick#Solar_Azimuth_Angle_Sensor,Measures the azimuth angle of the sun, https://brickschema.org/schema/Brick#Solar_Irradiance,The power per unit area of solar electromagnetic radiation incident on a surface, https://brickschema.org/schema/Brick#Solar_Irradiance_Sensor,Measures solar irradiance levels for photovoltaic systems, diff --git a/bricksrc/parameter.py b/bricksrc/parameter.py index 62497ed2..19f2f1c2 100644 --- a/bricksrc/parameter.py +++ b/bricksrc/parameter.py @@ -577,7 +577,12 @@ TAG.PID, ], "subclasses": { - "Differential_Pressure_Proportional_Band": { + "Differential_Pressure_Proportional_Band_Parameter": { + "aliases": [ + BRICK[ + "Differential_Pressure_Proportional_Band" + ] + ], "tags": [ TAG.Point, TAG.Differential, diff --git a/bricksrc/points.csv b/bricksrc/points.csv new file mode 100644 index 00000000..d1fdb40f --- /dev/null +++ b/bricksrc/points.csv @@ -0,0 +1,867 @@ +@id,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition +brick:Absolute_Humidity_Sensor,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity +brick:Acceleration_Time_Setpoint,,brick:Acceleration,,,quantitykind:Time,brick:Setpoint,, +brick:Active_Power_Sensor,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" +brick:Adjust_Sensor,,,,,,,(deprecated),Measures user-provided adjustment of some value +brick:Air_Alarm,,,brick:Air,,,brick:Alarm,, +brick:Air_Differential_Pressure_Sensor,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air +brick:Air_Differential_Pressure_Setpoint,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit +brick:Air_Enthalpy_Sensor,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air +brick:Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. +brick:Air_Flow_Deadband_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow +brick:Air_Flow_Demand_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of air flow required for a process +brick:Air_Flow_Loss_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. +brick:Air_Flow_Sensor,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air +brick:Air_Flow_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow +brick:Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Air_Grains_Sensor,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air +brick:Air_Pressure_Sensor,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. +brick:Air_Pressure_Setpoint,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, +brick:Air_Quality_Sensor,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality +brick:Air_Static_Pressure_Sensor,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." +brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Air_Temperature_Alarm,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. +brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air +brick:Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air +brick:Air_Temperature_Setpoint_Limit,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. +brick:Air_Temperature_Step_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. +brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, +brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action +brick:Alarm_Delay_Parameter,,,,,,brick:Alarm_Delay_Parameter,,A parameter determining how long to delay an alarm after sufficient conditions have been met +brick:Alarm_Sensitivity_Parameter,,,,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate an alarm. +brick:Ammonia_Sensor,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air +brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon +brick:Automatic_Mode_Command,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" +brick:Availability_Status,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" +brick:Average_Cooling_Demand_Sensor,,brick:Cooling,,,,brick:Average_Demand_Sensor,,Measures the average power consumed by a cooling process as the amount of power consumed over some interval +brick:Average_Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Average_Sensor,,The computed average flow of discharge air over some interval +brick:Average_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Average_Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Average_Heating_Demand_Sensor,,brick:Heating,,,,brick:Average_Demand_Sensor,,Measures the average power consumed by a heating process as the amount of power consumed over some interval +brick:Average_Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Average_Sensor,,The computed average flow of supply air over some interval +brick:Average_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Average_Sensor,,"The computed average temperature of air in a zone, over some period of time" +brick:Battery_Voltage_Sensor,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery +brick:Boiler_Command,,brick:Boiler,,,,brick:Command,,A command to control a boiler +brick:Box_Mode_Command,,,,,,,(deprecated), +brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building +brick:Building_Air_Static_Pressure_Sensor,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building +brick:Building_Air_Static_Pressure_Setpoint,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building +brick:Bypass_Air_Flow_Sensor,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air +brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air +brick:Bypass_Command,,,,,,,(deprecated), +brick:Bypass_Water_Flow_Sensor,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water +brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water +brick:Capacity_Sensor,,,,,quantitykind:Capacity,brick:Sensor,, +brick:Change_Filter_Alarm,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed +brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water +brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Chilled_Water_Differential_Pressure_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve +brick:Chilled_Water_Differential_Pressure_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water +brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Chilled_Water_Differential_Temperature_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device +brick:Chilled_Water_Flow_Sensor,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit +brick:Chilled_Water_Flow_Setpoint,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water +brick:Chilled_Water_Gauge_Pressure_Sensor,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water +brick:Chilled_Water_Static_Pressure_Setpoint,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water +brick:Chilled_Water_System_Enable_Command,,brick:Chilled_Water_System,,,,brick:Enable_Command,,Enables operation of the chilled water system +brick:Chilled_Water_Temperature_Sensor,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water +brick:Chilled_Water_Temperature_Setpoint,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water +brick:Close_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. +brick:CO_Differential_Sensor,,,brick:CO,brick:Differential,,brick:Sensor,, +brick:CO_Level_Sensor,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO +brick:CO_Sensor,,,brick:CO,,,brick:Sensor,,Measures properties of CO +brick:CO2_Alarm,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. +brick:CO2_Alarm_Sensitivity_Parameter,,,brick:CO2,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a CO2 alarm. +brick:CO2_Differential_Sensor,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air +brick:CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air +brick:CO2_Sensor,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air +brick:CO2_Setpoint,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 +brick:Coldest_Zone_Air_Temperature_Sensor,,,,,,,(deprecated),The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Command,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. +brick:Communication_Loss_Alarm,,,,,brick:EnumerationKind-CommunicationState,brick:Loss_Alarm,,An alarm that indicates a loss of communication e.g. with a device or controller +brick:Condensate_Leak_Alarm,,,brick:Condensate,,,brick:Leak_Alarm,,An alarm that indicates a leak of condensate from a cooling system +brick:Condenser_Water_Flow_Sensor,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water +brick:Condenser_Water_Flow_Setpoint,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Condenser_Water_Temperature_Sensor,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water +brick:Conductivity_Sensor,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance +brick:Contact_Sensor,,,,,,,(deprecated),"Senses or detects contact, such as for determining if a door is closed." +brick:Cooling_Command,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) +brick:Cooling_Demand_Sensor,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Cooling_Demand_Setpoint,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling +brick:Cooling_Discharge_Air_Flow_Setpoint,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling +brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of cooling discharge air +brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Enable_Command,,brick:Cooling,,,,brick:Enable_Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Mode_Status,,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" +brick:Cooling_Start_Stop_Status,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Cooling_Supply_Air_Flow_Setpoint,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling +brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for cooling +brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Temperature_Setpoint,,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling +brick:Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The cooling setpoint for a specific zone in a building. +brick:Core_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. +brick:Core_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." +brick:Current_Imbalance_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system +brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. +brick:Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a device +brick:Current_Ratio_Setpoint,,,,,,,(deprecated),Sets the ratio of currents in a transformer +brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor +brick:Curtailment_Override_Command,,,,,,,(deprecated), +brick:Cycle_Alarm,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with HVAC cycles +brick:Damper_Command,,brick:Damper,,,,brick:Command,,Controls properties of dampers +brick:Damper_Position_Command,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper +brick:Damper_Position_Sensor,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open +brick:Damper_Position_Setpoint,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper +brick:Damper_Position_Status,,brick:Damper,,,,brick:Status,Position, +brick:DC_Bus_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage across a DC bus +brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband +brick:Deceleration_Time_Setpoint,,brick:Deceleration,,,quantitykind:Time,brick:Setpoint,, +brick:Dehumidification_Start_Stop_Status,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Dehumidify_Command,,brick:Dehumidification,,,,brick:Enable_Command,,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Deionised_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water +brick:Deionised_Water_Level_Sensor,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container +brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. +brick:Delay_Parameter,,,,,,brick:Delay_Parameter,,A parameter determining how long to delay a subsequent action to take place after a received signal +brick:Demand_Sensor,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Demand_Setpoint,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process +brick:Derivative_Gain_Parameter,,,,,,brick:Derivative_Gain_Parameter,, +brick:Derivative_Time_Parameter,,,,,,brick:Derivative_Time_Parameter,, +brick:Dewpoint_Sensor,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor +brick:Dewpoint_Setpoint,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point +brick:Differential_Air_Temperature_Setpoint,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,(deprecated),Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure +brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Differential_Pressure_Proportional_Band,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures +brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure +brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. +brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements +brick:Differential_Speed_Sensor,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, +brick:Differential_Speed_Setpoint,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed +brick:Differential_Temperature_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements +brick:Direction_Command,,,,,,,(deprecated),Commands that affect the direction of some phenomenon +brick:Direction_Sensor,,,,,,,(deprecated),Measures the direction in degrees in which a phenomenon is occuring +brick:Direction_Status,,,,,,,(deprecated),Indicates which direction a device is operating in +brick:Disable_Command,,,,,,brick:Disable_Command,,Commands that disable functionality +brick:Disable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Disable_Command,,Disables the use of differential enthalpy control +brick:Disable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Disable_Command,,Disables the use of differential temperature control +brick:Disable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Disable_Command,Fixed,Disables the use of fixed enthalpy control +brick:Disable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Disable_Command,Fixed,Disables the use of fixed temperature temperature +brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Disable_Setpoint,,Disables hot water system when outside air temperature reaches the indicated value +brick:Disable_Status,,,,,,brick:Disable_Status,,Indicates if functionality has been disabled +brick:Discharge_Air_Dewpoint_Sensor,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air +brick:Discharge_Air_Differential_Pressure_Sensor,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, +brick:Discharge_Air_Differential_Pressure_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Discharge_Air_Duct_Pressure_Status,,,,,,,(deprecated),Indicates if air pressure in discharge duct is within expected bounds +brick:Discharge_Air_Flow_Demand_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of discharge air flow required for a process +brick:Discharge_Air_Flow_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, +brick:Discharge_Air_Flow_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies +brick:Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air +brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow +brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air +brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air +brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,brick:Integral_Gain_Parameter,, +brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, +brick:Discharge_Air_Smoke_Detection_Alarm,,brick:Smoke_Detection,brick:Discharge_Air,,,brick:Alarm,, +brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Discharge_Air_Static_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system +brick:Discharge_Air_Static_Pressure_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. +brick:Discharge_Air_Temperature_Cooling_Setpoint,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for cooling +brick:Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air +brick:Discharge_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for heating +brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. +brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water +brick:Domestic_Hot_Water_System_Enable_Command,,brick:Domestic_Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water +brick:Drive_Ready_Status,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" +brick:Duct_Air_Static_Pressure_Setpoint,,,,,,,(deprecated), +brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event +brick:EconCycle_Start_Stop_Status,,,,,,,(deprecated), +brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. +brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective heating setpoint for a specific zone in a building. +brick:Effective_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Room_Air_Temperature_Setpoint,,,brick:Room_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width +brick:Electric_Energy_Sensor,,,,,quantitykind:Energy,brick:Sensor,Electric, +brick:Electric_Power_Sensor,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed +brick:Electrical_Energy_Usage_Sensor,,,,,quantitykind:Energy,brick:Sensor,Electric Usage,A sensor that records the quantity of electrical energy consumed in a given period +brick:Embedded_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. +brick:Embedded_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." +brick:Emergency_Air_Flow_System_Status,,brick:Emergency_Air_Flow_System,,,,brick:Status,, +brick:Emergency_Alarm,,,,,,,(deprecated),Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Generator_Alarm,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,,,,,,(deprecated),Indicates if an emergency generator is active +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Status,,,,,,,(deprecated), +brick:Emergency_Push_Button_Status,,,,,,,(deprecated),Indicates if an emergency button has been pushed +brick:Enable_Command,,,,,,brick:Enable_Command,,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Enable_Command,,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Enable_Command,,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Enable_Command,Fixed,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Enable_Command,Fixed,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,,Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,brick:Enable_Status,,Indicates if a system or piece of functionality has been enabled +brick:Energy_Generation_Sensor,,,,,quantitykind:Energy,brick:Sensor,Generation,A sensor measuring the amount of generated energy. +brick:Energy_Sensor,,,,,quantitykind:Energy,brick:Sensor,,Measures energy consumption +brick:Energy_Usage_Sensor,,,,,quantitykind:Energy,brick:Sensor,Usage,Measures the total amount of energy used over some period of time +brick:Entering_Chilled_Water_Flow_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water +brick:Entering_Chilled_Water_Flow_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water +brick:Entering_Chilled_Water_Temperature_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower +brick:Entering_Chilled_Water_Temperature_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water +brick:Entering_Condenser_Water_Flow_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Setpoint,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water +brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Entering_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water enteringed to a hot water system +brick:Entering_Hot_Water_Flow_Sensor,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water +brick:Entering_Hot_Water_Flow_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water +brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Sensor,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system +brick:Entering_Hot_Water_Temperature_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water entering a hot water system +brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water +brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Flow_Sensor,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system +brick:Entering_Water_Flow_Setpoint,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water +brick:Entering_Water_Pressure_Sensor,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. +brick:Entering_Water_Temperature_Alarm,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. +brick:Entering_Water_Temperature_Deadband_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water +brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water +brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water +brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance +brick:Enthalpy_Setpoint,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy +brick:Even_Month_Status,,,,,,,(deprecated), +brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air +brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building +brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit +brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air +brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate +brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air +brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air +brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of exhaust air stack flow +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Stack_Flow_Sensor,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in the exhaust air stack +brick:Exhaust_Air_Stack_Flow_Setpoint,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air stack flow rate +brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system +brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air +brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air +brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Failure_Alarm,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" +brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans +brick:Fan_On_Off_Status,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans +brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans +brick:Fault_Reset_Command,,,,,,brick:Fault_Reset_Command,,Clears a fault status +brick:Fault_Status,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" +brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. +brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter +brick:Filter_Reset_Command,,brick:Filter,,,,brick:Reset_Command,, +brick:Filter_Status,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced +brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. +brick:Fire_Sensor,,,brick:Fire,,,brick:Sensor,,Measures the presence of fire +brick:Flow_Sensor,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance +brick:Flow_Setpoint,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow +brick:Formaldehyde_Level_Sensor,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air +brick:Freeze_Status,,,,,,,(deprecated),Indicates if a substance contained within a vessel has frozen +brick:Frequency_Command,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) +brick:Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" +brick:Frequency_Setpoint,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency +brick:Fresh_Air_Setpoint_Limit,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Frost_Sensor,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost +brick:Fume_Hood_Air_Flow_Sensor,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood +brick:Gain_Parameter,,,,,,brick:Gain_Parameter,, +brick:Gas_Sensor,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) +brick:Gauge_Pressure_Sensor,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure +brick:Generation_Sensor,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. +brick:Hail_Sensor,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential +brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger_System,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled +brick:Heat_Sink_Temperature_Sensor,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. +brick:Heating_Command,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) +brick:Heating_Demand_Sensor,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Heating_Demand_Setpoint,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating +brick:Heating_Discharge_Air_Flow_Setpoint,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating +brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of heating discharge air +brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Enable_Command,,brick:Heating,,,,brick:Enable_Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Mode_Status,,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" +brick:Heating_Start_Stop_Status,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Heating_Supply_Air_Flow_Setpoint,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating +brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for heating +brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Temperature_Setpoint,,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating +brick:Heating_Thermal_Power_Sensor,,brick:Heating,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The heating setpoint for a specific zone in a building. +brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. +brick:High_CO2_Alarm,,,brick:CO2,,,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. +brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that discharge air temperature is too high +brick:High_Head_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated),The upper bound of the outside air temperature lockout range +brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. +brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, +brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. +brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm +brick:Hold_Status,,,,,,,(deprecated), +brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water +brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve +brick:Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water +brick:Hot_Water_Differential_Temperature_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device +brick:Hot_Water_Flow_Sensor,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit +brick:Hot_Water_Flow_Setpoint,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water +brick:Hot_Water_Gauge_Pressure_Sensor,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water +brick:Hot_Water_Static_Pressure_Setpoint,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air +brick:Hot_Water_System_Enable_Command,,brick:Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the hot water system +brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water +brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" +brick:Humidification_Start_Stop_Status,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier +brick:Humidify_Command,,brick:Humidification,,,,brick:Enable_Command,, +brick:Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. +brick:Humidity_Deadband_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity +brick:Humidity_Parameter,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points +brick:Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air +brick:Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity +brick:Humidity_Tolerance_Parameter,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. +brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Ice_Tank,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving an ice tank +brick:Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" +brick:Illuminance_Setpoint,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. +brick:Imbalance_Sensor,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system +brick:Inside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. +brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. +brick:Intake_Air_Temperature_Sensor,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside +brick:Integral_Gain_Parameter,,,,,,brick:Integral_Gain_Parameter,, +brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, +brick:Last_Fault_Code_Status,,,,,,,(deprecated),Indicates the last fault code that occurred +brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation +brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled +brick:Lead_On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" +brick:Leak_Alarm,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids +brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water +brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water +brick:Leaving_Chilled_Water_Temperature_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller +brick:Leaving_Chilled_Water_Temperature_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water +brick:Leaving_Condenser_Water_Flow_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Setpoint,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water +brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of domestic water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leavinging part of domestic hot water +brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Leaving_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water supplied by a hot water system +brick:Leaving_Hot_Water_Flow_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water +brick:Leaving_Hot_Water_Flow_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water +brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system +brick:Leaving_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water supplied by a hot water system +brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water +brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Flow_Sensor,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system +brick:Leaving_Water_Flow_Setpoint,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water +brick:Leaving_Water_Pressure_Sensor,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. +brick:Leaving_Water_Temperature_Alarm,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. +brick:Leaving_Water_Temperature_Deadband_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water +brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system +brick:Leaving_Water_Temperature_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water +brick:Level_Command,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. +brick:Level_Status,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. +brick:Lighting_Correlated_Color_Temperature_Command,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Correlated_Color_Temperature_Sensor,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Level_Command,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. +brick:Limit,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point +brick:Liquid_Detection_Alarm,,brick:Liquid_Detection,,,,brick:Alarm,, +brick:Load_Current_Sensor,,,,,,,(deprecated),Measures the current consumed by a load +brick:Load_Parameter,,,,,,,(deprecated), +brick:Load_Setpoint,,,,,,,(deprecated), +brick:Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,,Controls load shedding behavior provided by a control system +brick:Load_Shed_Differential_Pressure_Setpoint,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Load_Shed_Setpoint,,brick:Load_Shed,,,,brick:Setpoint,, +brick:Load_Shed_Status,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect +brick:Locally_On_Off_Status,,,,,,,(deprecated), +brick:Lockout_Status,,,,,,,(deprecated),"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated), +brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. +brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. +brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. +brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Alarm,, +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,(deprecated), +brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated),The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), +brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,(deprecated), +brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low +brick:Low_Suction_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,, +brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Alarm,, +brick:Low_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. +brick:Low_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Low_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm +brick:Low_Voltage_Alarm,,,,,quantitykind:Voltage,brick:Low_Alarm,,An alarm that indicates the voltage is lower than its normal state. +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,,,,,(deprecated),The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Luminance_Alarm,,,,,quantitykind:Luminance,brick:Alarm,, +brick:Luminance_Command,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system +brick:Luminance_Sensor,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction +brick:Luminance_Setpoint,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance +brick:Maintenance_Mode_Command,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" +brick:Maintenance_Required_Alarm,,,,,brick:EnumerationKind-Maintenance_Required,brick:Alarm,,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Manual_Auto_Status,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation +brick:Max_Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Max_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for maximum air temperature +brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Max_Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Max_Frequency_Command,,,,,quantitykind:Frequency,brick:Max_Command,,Sets the maximum permitted frequency +brick:Max_Fresh_Air_Setpoint_Limit,,,brick:Fresh_Air,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Max_Limit,,,,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. +brick:Max_Load_Setpoint,,,,,,,(deprecated), +brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Outside_Air_Flow_Setpoint_Limit,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Max_Position_Setpoint_Limit,,,,,,brick:Max_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. +brick:Max_Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Max_Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Max_Temperature_Setpoint_Limit,,,,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. +brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Water_Level_Alarm,,,brick:Water,,,brick:Max_Alarm,Level,Alarm indicating that the maximum water level was reached +brick:Max_Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for max water temperature +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between sections of a medium temperature hot water system +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Methane_Level_Sensor,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air +brick:Min_Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Min_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for minimum air temperature +brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Min_Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Min_Frequency_Command,,,,,quantitykind:Frequency,brick:Min_Command,, +brick:Min_Fresh_Air_Setpoint_Limit,,,brick:Fresh_Air,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Min_Limit,,,,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. +brick:Min_Load_Setpoint,,,,,,,(deprecated), +brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Outside_Air_Flow_Setpoint_Limit,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Min_Position_Setpoint_Limit,,,,,,brick:Min_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. +brick:Min_Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Min_Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Min_Temperature_Setpoint_Limit,,,,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. +brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Water_Level_Alarm,,,brick:Water,,,brick:Min_Alarm,Level,Alarm indicating that the minimum water level was reached +brick:Min_Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for min water temperature +brick:Mixed_Air_Flow_Sensor,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air +brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air +brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air +brick:Mixed_Air_Temperature_Sensor,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air +brick:Mixed_Air_Temperature_Setpoint,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air +brick:Mode_Command,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the operating mode of a device or controller +brick:Mode_Status,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" +brick:Motion_Sensor,,,,,brick:EnumerationKind-Motion,brick:Sensor,,Detects the presence of motion in some area +brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor +brick:Motor_Direction_Status,,brick:Motor,,,brick:EnumerationKind-Forward_Reverse,brick:Status,,"Indicates which direction a motor is operating in, e.g. forward or reverse" +brick:Motor_On_Off_Status,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Motor_Speed_Sensor,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, +brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" +brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas +brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas +brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" +brick:No_Water_Alarm,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system +brick:NO2_Level_Sensor,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air +brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" +brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area +brick:Occupancy_Sensor,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area +brick:Occupancy_Status,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied +brick:Occupied_Air_Temperature_Setpoint,brick:Occupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when occupied +brick:Occupied_Cooling_Mode_Status,brick:Occupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling when occupied +brick:Occupied_Cooling_Temperature_Deadband_Setpoint,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for cooling when occupied +brick:Occupied_Cooling_Temperature_Setpoint,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling when occupied +brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,brick:Occupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air cooling when occupied +brick:Occupied_Discharge_Air_Flow_Setpoint,brick:Occupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow when occupied +brick:Occupied_Discharge_Air_Temperature_Setpoint,brick:Occupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating when occupied +brick:Occupied_Heating_Mode_Status,brick:Occupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Occupied_Heating_Supply_Air_Flow_Setpoint,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating when occupied +brick:Occupied_Heating_Temperature_Deadband_Setpoint,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for heating when occupied +brick:Occupied_Heating_Temperature_Setpoint,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating when occupied +brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,brick:Occupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air heating when occupied +brick:Occupied_Humidity_Setpoint,brick:Occupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is occupied. +brick:Occupied_Load_Shed_Command,brick:Occupied,brick:Load_Shed,,,,brick:Command,, +brick:Occupied_Mode_Status,brick:Occupied,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates if a system, device or control loop is in ""Occupied"" mode" +brick:Occupied_Return_Air_Temperature_Setpoint,brick:Occupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Room_Air_Temperature_Setpoint,brick:Occupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Supply_Air_Flow_Setpoint,brick:Occupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied +brick:Occupied_Supply_Air_Temperature_Setpoint,brick:Occupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Target_Zone_Air_Temperature_Setpoint,brick:Occupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Off_Command,,,,,brick:On_Off-Off,brick:Command,,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" +brick:Off_Status,,,,,brick:On_Off-Off,brick:Status,,"Indicates if a control loop, relay or equipment is off" +brick:On_Command,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" +brick:On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" +brick:On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" +brick:On_Status,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" +brick:On_Timer_Sensor,,,,,brick:On_Off-On,brick:Sensor,Timer,"Measures the duration for which a device was in an active or ""on"" state" +brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" +brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" +brick:Output_Frequency_Sensor,,,,,,,(deprecated), +brick:Output_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage output by some process or device +brick:Outside_Air_CO_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air +brick:Outside_Air_CO2_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air +brick:Outside_Air_Dewpoint_Sensor,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air +brick:Outside_Air_Enthalpy_Sensor,,,brick:Outside_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air +brick:Outside_Air_Flow_Sensor,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system +brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate +brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air +brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air +brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated), +brick:Outside_Air_Lockout_Temperature_Setpoint,,,,,,,(deprecated), +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), +brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air +brick:Outside_Air_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air +brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air +brick:Outside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. +brick:Outside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. +brick:Outside_Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" +brick:Overload_Alarm,,,,,,brick:Alarm,Overload,An alarm that can indicate when a full-load current is exceeded. +brick:Overridden_Off_Status,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" +brick:Overridden_On_Status,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" +brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden +brick:Override_Command,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' +brick:Ozone_Level_Sensor,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air +brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values +brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air +brick:Peak_Demand_Sensor,,,,,,brick:Demand_Sensor,Peak,The peak power consumed by a process over some period of time +brick:Photovoltaic_Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device +brick:PID_Parameter,,,,,,brick:PID_Parameter,, +brick:Piezoelectric_Sensor,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:PM1_Level_Sensor,,,brick:PM1.0,,,brick:Sensor,Level,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,brick:PM1.0,,,brick:Sensor,,Detects matter of size 1 micron +brick:PM10_Level_Sensor,,,brick:PM10.0,,,brick:Sensor,Level,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,brick:PM10.0,,,brick:Sensor,,Detects matter of size 10 microns +brick:PM2.5_Level_Sensor,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns +brick:PM2.5_Sensor,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns +brick:Position_Command,,,,,,brick:Command,Position,Controls or reports the position of some object +brick:Position_Limit,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. +brick:Position_Sensor,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion +brick:Power_Alarm,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. +brick:Power_Factor_Sensor,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." +brick:Power_Loss_Alarm,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. +brick:Power_Sensor,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed +brick:Pre_Filter_Status,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced +brick:Preheat_Command,,brick:Preheat,,,,brick:Command,,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer +brick:Preheat_Demand_Setpoint,,brick:Preheat,,,,brick:Demand_Setpoint,,Sets the rate required for preheat +brick:Preheat_Discharge_Air_Temperature_Sensor,,brick:Preheat,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air before heating is applied +brick:Preheat_Supply_Air_Temperature_Sensor,,brick:Preheat,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air before it is heated +brick:Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. +brick:Pressure_Sensor,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area +brick:Pressure_Setpoint,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure +brick:Pressure_Status,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds +brick:Proportional_Band_Parameter,,,,,,brick:Proportional_Band_Parameter,, +brick:Proportional_Gain_Parameter,,,,,,brick:Proportional_Gain_Parameter,, +brick:Pump_Command,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) +brick:Pump_On_Off_Status,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump +brick:PV_Current_Output_Sensor,,,,,,,(deprecated),See Photovoltaic_Current_Output_Sensor +brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. +brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. +brick:Radon_Concentration_Sensor,,,brick:Rn,,quantitykind:ActivityConcentration,brick:Sensor,,Measures the concentration of radioactivity due to radon +brick:Rain_Duration_Sensor,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame +brick:Rain_Level_Sensor,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen +brick:Rated_Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed +brick:Reactive_Energy_Sensor,,,,,quantitykind:Energy,brick:Sensor,Reactive,Measures the integral of reactive power +brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" +brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, +brick:Reheat_Command,,brick:Reheat,,,,brick:Command,,"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature +brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay +brick:Remotely_On_Off_Status,,,,,,,(deprecated), +brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" +brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies +brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air +brick:Return_Air_CO2_Sensor,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air +brick:Return_Air_CO2_Setpoint,,,brick:Return_Air,,,brick:Setpoint,CO2,Sets some property of CO2 in Return Air +brick:Return_Air_Dewpoint_Sensor,,,brick:Return_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air +brick:Return_Air_Differential_Pressure_Sensor,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side +brick:Return_Air_Differential_Pressure_Setpoint,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit +brick:Return_Air_Enthalpy_Sensor,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air +brick:Return_Air_Flow_Sensor,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air +brick:Return_Air_Grains_Sensor,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air +brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air +brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air +brick:Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. +brick:Return_Air_Temperature_High_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Return_Air_Temperature_Low_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Return_Air_Temperature_Sensor,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air +brick:Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" +brick:Room_Air_Temperature_Sensor,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, +brick:Room_Air_Temperature_Setpoint,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air +brick:Run_Enable_Command,,brick:Run,,,,brick:Enable_Command,, +brick:Run_Request_Status,,brick:Run,,,,brick:Status,Request,Indicates if a request has been filed to start a device or equipment +brick:Run_Status,,brick:Run,,,,brick:Status,, +brick:Run_Time_Sensor,,brick:Run,,,quantitykind:Time,brick:Sensor,,"Measures the duration for which a device was in an active or ""on"" state" +brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule +brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). +brick:Sensor_Failure_Alarm,,,,,,brick:Sensor_Failure_Alarm,, +brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set +brick:Short_Cycle_Alarm,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Smoke_Alarm,,,brick:Smoke,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with smoke. +brick:Smoke_Detection_Alarm,,brick:Smoke_Detection,,,,brick:Alarm,, +brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil +brick:Solar_Azimuth_Angle_Sensor,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun +brick:Solar_Irradiance_Sensor,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems +brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun +brick:Speed_Command,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. +brick:Speed_Mode_Status,,,,,brick:EnumerationKind-Speed_Mode,brick:Status,,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Reset_Command,, +brick:Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement +brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed +brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. +brick:Stage_Enable_Command,,,,,,brick:Enable_Command,Stage,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in +brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit +brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Standby_Load_Shed_Command,,,,,,,(deprecated), +brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Standby_Unit_On_Off_Status,,,,,,,(deprecated),Indicates the on/off status of a standby unit +brick:Start_Stop_Command,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence +brick:Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) +brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure +brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Static_Pressure_Sensor,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work +brick:Static_Pressure_Setpoint,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure +brick:Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Status,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" +brick:Steam_On_Off_Command,,,brick:Steam,,brick:EnumerationKind-On_Off,brick:Command,, +brick:Steam_Usage_Sensor,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" +brick:Step_Parameter,,,,,,brick:Step_Parameter,, +brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, +brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building +brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit +brick:Supply_Air_Duct_Pressure_Status,,,,,,,(deprecated),Indicates if air pressure in supply duct is within expected bounds +brick:Supply_Air_Flow_Demand_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process +brick:Supply_Air_Flow_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, +brick:Supply_Air_Flow_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air +brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate +brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air +brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air +brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,brick:Integral_Gain_Parameter,, +brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, +brick:Supply_Air_Smoke_Detection_Alarm,,brick:Smoke_Detection,brick:Supply_Air,,,brick:Alarm,, +brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air +brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Static_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system +brick:Supply_Air_Static_Pressure_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air +brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. +brick:Supply_Air_Temperature_Cooling_Setpoint,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air +brick:Supply_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air +brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air +brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Switch_Status,,brick:Switch,,,,brick:Status,,Status of a switch +brick:System_Enable_Command,,brick:System,,,,brick:Enable_Command,,Enables operation of a system +brick:System_Shutdown_Status,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown +brick:System_Status,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system +brick:Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, +brick:Temperature_Adjust_Sensor,,,,,,,(deprecated),Measures user-provided adjustment of temperature +brick:Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. +brick:Temperature_Alarm_Sensitivity_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. +brick:Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature +brick:Temperature_Differential_Reset_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_High_Reset_Setpoint,,,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Temperature_Low_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points +brick:Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold +brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature +brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. +brick:Temporary_Occupancy_Status,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Thermal_Energy_Usage_Sensor,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period +brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat +brick:Time_Parameter,,,,,quantitykind:Time,brick:Parameter,, +brick:Time_Setpoint,,,,,quantitykind:Time,brick:Setpoint,, +brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. +brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." +brick:Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. +brick:Torque_Sensor,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" +brick:TVOC_Level_Sensor,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the level of all VOCs in air +brick:TVOC_Sensor,,,brick:VOC,,,brick:Sensor,, +brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum +brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure +brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air +brick:Unit_Failure_Alarm,,,,,,,(deprecated),An alarm that indicates the failure of an equipment or device +brick:Unoccupied_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied +brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied +brick:Unoccupied_Cooling_Mode_Status,brick:Unoccupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" +brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Cooling_Temperature_Setpoint,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,brick:Unoccupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for cooling within a specific zone +brick:Unoccupied_Discharge_Air_Flow_Setpoint,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Discharge_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Mode_Status,brick:Unoccupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied heating mode" +brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Heating_Temperature_Setpoint,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,brick:Unoccupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for heating within a specific zone +brick:Unoccupied_Humidity_Setpoint,brick:Unoccupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is unoccupied. +brick:Unoccupied_Load_Shed_Command,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,, +brick:Unoccupied_Mode_Status,brick:Unoccupied,,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Unoccupied_Return_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Room_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Flow_Setpoint,brick:Unoccupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Usage_Sensor,,,,,,brick:Sensor,Usage,"Measures the amount of some substance that is consumed or used, over some period of time" +brick:Valve_Command,,brick:Valve,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) +brick:Valve_Position_Alarm,,brick:Valve,,,,brick:Alarm,Position,An alarm that indicates that the valve position is not in a normal state. +brick:Valve_Position_Command,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve +brick:Valve_Position_Sensor,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open +brick:Valve_Status,,brick:Valve,,,,brick:Status,,The current status of the valve. +brick:Velocity_Pressure_Sensor,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure +brick:Velocity_Pressure_Setpoint,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure +brick:Vent_Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,Vent,Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:VFD_Enable_Command,,brick:VFD,,,,brick:Enable_Command,,Enables operation of a variable frequency drive +brick:Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. +brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system +brick:Voltage_Ratio_Setpoint,,,,,,,(deprecated),Sets the ratio of voltage in a transformer +brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object +brick:Warm_Cool_Adjust_Sensor,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warmest_Zone_Air_Temperature_Sensor,,,,,,,(deprecated),The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Waste_Amount_Sensor,,,,,,,(deprecated),A metric used for measuring the quantity of waste generated in a building. +brick:Water_Alarm,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" +brick:Water_Differential_Pressure_Sensor,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. +brick:Water_Differential_Pressure_Setpoint,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit +brick:Water_Differential_Temperature_Sensor,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit +brick:Water_Differential_Temperature_Setpoint,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit +brick:Water_Flow_Sensor,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water +brick:Water_Flow_Setpoint,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water +brick:Water_Level_Alarm,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin +brick:Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container +brick:Water_Loss_Alarm,,,brick:Water,,,brick:Loss_Alarm,,An alarm that indicates a loss of water e.g. during transport +brick:Water_Pressure_Sensor,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. +brick:Water_Pressure_Setpoint,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, +brick:Water_Temperature_Alarm,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. +brick:Water_Temperature_Sensor,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water +brick:Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water +brick:Water_Usage_Sensor,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" +brick:Wind_Direction_Sensor,,,brick:Wind,,quantitykind:Azimuth,brick:Sensor,,Measures the direction of wind in degrees relative to North +brick:Wind_Speed_Sensor,,,brick:Wind,,quantitykind:Speed,brick:Sensor,,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,brick:EnumerationKind-Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone +brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air +brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air +brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air +brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone +brick:Zone_CO2_Level_Sensor,,,brick:Zone_Air,,,brick:Sensor,CO2 Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone +brick:Zone_Occupied_Load_Shed_Command,brick:Occupied,brick:Load_Shed,,,,brick:Command,Zone, +brick:Zone_Standby_Load_Shed_Command,,,,,,,(deprecated), +brick:Zone_Unoccupied_Load_Shed_Command,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,Zone, diff --git a/bricksrc/sensor.py b/bricksrc/sensor.py index 3bf166a6..6a4b2649 100644 --- a/bricksrc/sensor.py +++ b/bricksrc/sensor.py @@ -329,7 +329,8 @@ "tags": [TAG.Point, TAG.Sensor, TAG.Conductivity], BRICK.hasQuantity: QUDTQK.Conductivity, "subclasses": { - "Deionised_Water_Conductivity_Sensor": { + "Deionized_Water_Conductivity_Sensor": { + "aliases": [BRICK["Deionised_Water_Conductivity_Sensor"]], "tags": [ TAG.Point, TAG.Sensor, @@ -1538,7 +1539,8 @@ BRICK.hasQuantity: BRICK.Level, BRICK.hasSubstance: BRICK.Water, "subclasses": { - "Deionised_Water_Level_Sensor": { + "Deionized_Water_Level_Sensor": { + "aliases": [BRICK["Deionised_Water_Level_Sensor"]], "tags": [ TAG.Point, TAG.Sensor, diff --git a/bricksrc/substances.py b/bricksrc/substances.py index 0a5af83e..02b03e4c 100644 --- a/bricksrc/substances.py +++ b/bricksrc/substances.py @@ -5,6 +5,9 @@ "Light": { "tags": [TAG.Light], }, + "Solar": { + "tags": [TAG.Solar], + }, "Fluid": { SKOS.narrower: { "Refrigerant": {}, @@ -27,10 +30,17 @@ }, }, }, - "CO2": {}, - "CO": {}, - "Steam": {}, + "CH2O": {}, # Formaldehyde + "CH4": {}, # Methane + "CO": {}, # Carbon monoxide + "CO2": {}, # Carbon dioxide "Natural_Gas": {}, + "NH3": {}, # Ammonia + "NO2": {}, # Nitrogen dioxide + "O3": {}, # Ozone + "Rn": {}, # Radon + "Steam": {}, + "VOC": {}, # Volatile organic compounds }, }, "Liquid": { @@ -98,4 +108,11 @@ "Soil": {}, }, }, + "Particulate_Matter": { + SKOS.narrower: { + "PM1": {}, + "PM2.5": {}, + "PM10": {}, + }, + }, }