From 3ca316fb48c67677d71f0dfe0dc8c773d4d785b2 Mon Sep 17 00:00:00 2001 From: ektrah Date: Mon, 18 Aug 2025 07:56:31 +0200 Subject: [PATCH 01/31] Define all point attributes [no ci] --- bricksrc/points.csv | 867 ++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 867 insertions(+) create mode 100644 bricksrc/points.csv diff --git a/bricksrc/points.csv b/bricksrc/points.csv new file mode 100644 index 00000000..60d2b390 --- /dev/null +++ b/bricksrc/points.csv @@ -0,0 +1,867 @@ +@id,brick:isAggregated,brick:ofEquipment,brick:hasSubstance,brick:isDifferential,brick:hasQuantity,rdfs:subClassOf,todo:,skos:definition +brick:Absolute_Humidity_Sensor,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity +brick:Acceleration_Time_Setpoint,,,,,,brick:Setpoint,Acceleration Time, +brick:Active_Power_Sensor,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" +brick:Adjust_Sensor,,,,,,brick:Sensor,Adjust,Measures user-provided adjustment of some value +brick:Air_Alarm,,,brick:Air,,,brick:Alarm,, +brick:Air_Differential_Pressure_Sensor,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air +brick:Air_Differential_Pressure_Setpoint,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit +brick:Air_Enthalpy_Sensor,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air +brick:Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. +brick:Air_Flow_Deadband_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow +brick:Air_Flow_Demand_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of air flow required for a process +brick:Air_Flow_Loss_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,Loss,An alarm that indicates loss in air flow. +brick:Air_Flow_Sensor,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air +brick:Air_Flow_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow +brick:Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Air_Grains_Sensor,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air +brick:Air_Pressure_Sensor,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. +brick:Air_Pressure_Setpoint,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, +brick:Air_Quality_Sensor,,,brick:Air,,,brick:Sensor,Quality,A sensor which provides a measure of air quality +brick:Air_Static_Pressure_Sensor,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." +brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Air_Temperature_Alarm,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. +brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Parameter,Integral Time, +brick:Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air +brick:Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air +brick:Air_Temperature_Setpoint_Limit,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. +brick:Air_Temperature_Step_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Parameter,Step, +brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,quantitykind:Velocity,brick:Sensor,Pressure,Measures the difference between total air pressure and static air pressure. +brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, +brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action +brick:Alarm_Delay_Parameter,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met +brick:Alarm_Sensitivity_Parameter,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. +brick:Ammonia_Sensor,,,,,,brick:Sensor,Ammonia, +brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon +brick:Automatic_Mode_Command,,,,,,brick:Command,Automatic Mode,"Controls whether or not a device or controller is operating in ""Automatic"" mode" +brick:Availability_Status,,,,,,brick:Status,Availability,"Indicates if a piece of equipment, system, or functionality is available for operation" +brick:Average_Cooling_Demand_Sensor,brick:Average,,,,,brick:Sensor,Cooling Demand,Measures the average power consumed by a cooling process as the amount of power consumed over some interval +brick:Average_Discharge_Air_Flow_Sensor,brick:Average,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of discharge air over some interval +brick:Average_Exhaust_Air_Static_Pressure_Sensor,brick:Average,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Average_Heating_Demand_Sensor,brick:Average,,,,,brick:Sensor,Heating Demand,Measures the average power consumed by a heating process as the amount of power consumed over some interval +brick:Average_Supply_Air_Flow_Sensor,brick:Average,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of supply air over some interval +brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" +brick:Battery_Voltage_Sensor,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery +brick:Boiler_Command,,brick:Boiler,,,,brick:Command,,A command to control a boiler +brick:Box_Mode_Command,,,,,,brick:Command,Box Mode, +brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,,brick:Setpoint,Humidity,Setpoint for humidity in a building +brick:Building_Air_Static_Pressure_Sensor,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building +brick:Building_Air_Static_Pressure_Setpoint,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building +brick:Bypass_Air_Flow_Sensor,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air +brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,,brick:Setpoint,Humidity,Humidity setpoint for bypass air +brick:Bypass_Command,,,,,,brick:Command,Bypass, +brick:Bypass_Water_Flow_Sensor,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water +brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water +brick:Capacity_Sensor,,,,,quantitykind:Capacity,brick:Sensor,, +brick:Change_Filter_Alarm,,brick:Filter,,,,brick:Alarm,Change,An alarm that indicates that a filter must be changed +brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water +brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,Load Shed, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, +brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Chilled_Water_Differential_Pressure_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve +brick:Chilled_Water_Differential_Pressure_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water +brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Step, +brick:Chilled_Water_Differential_Temperature_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device +brick:Chilled_Water_Flow_Sensor,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit +brick:Chilled_Water_Flow_Setpoint,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water +brick:Chilled_Water_Gauge_Pressure_Sensor,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water +brick:Chilled_Water_Static_Pressure_Setpoint,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water +brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water,,,brick:Command,System Enable,Enables operation of the chilled water system +brick:Chilled_Water_Temperature_Sensor,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water +brick:Chilled_Water_Temperature_Setpoint,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water +brick:Close_Limit,,,,,,brick:Limit,Close,A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. +brick:CO_Differential_Sensor,,,brick:CO,brick:Differential,,brick:Sensor,, +brick:CO_Level_Sensor,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO +brick:CO_Sensor,,,brick:CO,,,brick:Sensor,,Measures properties of CO +brick:CO2_Alarm,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. +brick:CO2_Alarm_Sensitivity_Parameter,,,brick:CO2,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a CO2 alarm. +brick:CO2_Differential_Sensor,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air +brick:CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air +brick:CO2_Sensor,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air +brick:CO2_Setpoint,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 +brick:Coldest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Coldest,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Command,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. +brick:Communication_Loss_Alarm,,,,,,brick:Alarm,Communication Loss,An alarm that indicates a loss of communication e.g. with a device or controller +brick:Condensate_Leak_Alarm,,,,,,brick:Alarm,Condensate Leak,An alarm that indicates a leak of condensate from a cooling system +brick:Condenser_Water_Flow_Sensor,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water +brick:Condenser_Water_Flow_Setpoint,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Condenser_Water_Temperature_Sensor,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water +brick:Conductivity_Sensor,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance +brick:Contact_Sensor,,,,,,brick:Sensor,Contact,"Senses or detects contact, such as for determining if a door is closed." +brick:Cooling_Command,,,,,,brick:Command,Cooling,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) +brick:Cooling_Demand_Sensor,,,,,,brick:Sensor,Cooling Demand,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Cooling_Demand_Setpoint,,,,,,brick:Setpoint,Cooling Demand,Sets the rate required for cooling +brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets discharge air flow for cooling +brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of cooling discharge air +brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Cooling Integral Time, +brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Cooling Proportional Band, +brick:Cooling_Enable_Command,,,,,,brick:Command,Cooling Enable,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Mode_Status,,,,,,brick:Status,Cooling Mode,"Indicates whether a system, device or control loop is in a cooling mode" +brick:Cooling_Start_Stop_Status,,,,,,brick:Status,Cooling Start Stop, +brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets supply air flow rate for cooling +brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of supply air for cooling +brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Cooling Integral Time, +brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Cooling Proportional Band, +brick:Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Cooling,Sets temperature for cooling +brick:Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Cooling,The cooling setpoint for a specific zone in a building. +brick:Core_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. +brick:Core_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." +brick:Current_Imbalance_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system +brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. +brick:Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device +brick:Current_Ratio_Setpoint,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer +brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor +brick:Curtailment_Override_Command,,,,,,brick:Command,Curtailment Override, +brick:Cycle_Alarm,,,,,,brick:Alarm,Cycle,An alarm that indicates off-normal conditions associated with HVAC cycles +brick:Damper_Command,,brick:Damper,,,,brick:Command,,Controls properties of dampers +brick:Damper_Position_Command,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper +brick:Damper_Position_Sensor,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open +brick:Damper_Position_Setpoint,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper +brick:Damper_Position_Status,,brick:Damper,,,,brick:Status,Position, +brick:DC_Bus_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,DC Bus,Measures the voltage across a DC bus +brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband +brick:Deceleration_Time_Setpoint,,,,,,brick:Setpoint,Deceleration Time, +brick:Dehumidification_Start_Stop_Status,,,,,,brick:Status,Dehumidification Start Stop, +brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Deionised_Water_Conductivity_Sensor,,,brick:Water,,quantitykind:Conductivity,brick:Sensor,Deionised,Measures the electrical conductance of deionised water +brick:Deionised_Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Deionised Level,Measures the height/level of deionised water in some container +brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. +brick:Delay_Parameter,,,,,,brick:Parameter,Delay,A parameter determining how long to delay a subsequent action to take place after a received signal +brick:Demand_Sensor,,,,,,brick:Sensor,Demand,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Demand_Setpoint,,,,,,brick:Setpoint,Demand,Sets the rate required for a process +brick:Derivative_Gain_Parameter,,,,,,brick:Parameter,Derivative Gain, +brick:Derivative_Time_Parameter,,,,,,brick:Parameter,Derivative Time, +brick:Dewpoint_Sensor,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor +brick:Dewpoint_Setpoint,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point +brick:Differential_Air_Temperature_Setpoint,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure +brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Differential_Pressure_Load_Shed_Status,,,,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, +brick:Differential_Pressure_Proportional_Band,,,,brick:Differential,quantitykind:Pressure,,Proportional Band, +brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures +brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure +brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. +brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Parameter,Step, +brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements +brick:Differential_Speed_Sensor,,,,brick:Differential,,brick:Sensor,Speed, +brick:Differential_Speed_Setpoint,,,,brick:Differential,,brick:Setpoint,Speed,Sets differential speed +brick:Differential_Temperature_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements +brick:Direction_Command,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon +brick:Direction_Sensor,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring +brick:Direction_Status,,,,,,brick:Status,Direction,Indicates which direction a device is operating in +brick:Disable_Command,,,,,,brick:Command,Disable,Commands that disable functionality +brick:Disable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Disable,Disables the use of differential enthalpy control +brick:Disable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Command,Disable,Disables the use of differential temperature control +brick:Disable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Command,Disable Fixed,Disables the use of fixed enthalpy control +brick:Disable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Command,Disable Fixed,Disables the use of fixed temperature temperature +brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Disable System Outside Air,Disables hot water system when outside air temperature reaches the indicated value +brick:Disable_Status,,,,,,brick:Status,Disable,Indicates if functionality has been disabled +brick:Discharge_Air_Dewpoint_Sensor,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air +brick:Discharge_Air_Differential_Pressure_Sensor,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, +brick:Discharge_Air_Differential_Pressure_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Discharge_Air_Duct_Pressure_Status,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds +brick:Discharge_Air_Flow_Demand_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of discharge air flow required for a process +brick:Discharge_Air_Flow_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,High, +brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,Low, +brick:Discharge_Air_Flow_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies +brick:Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air +brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow +brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,,brick:Sensor,Humidity,Measures the relative humidity of discharge air +brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,,brick:Setpoint,Humidity,Humidity setpoint for discharge air +brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, +brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Parameter,Proportional Gain, +brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Discharge_Air,,,brick:Alarm,Smoke Detection, +brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Parameter,Integral Time, +brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Discharge_Air_Static_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system +brick:Discharge_Air_Static_Pressure_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. +brick:Discharge_Air_Temperature_Cooling_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Cooling,Sets temperature of discharge air for cooling +brick:Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air +brick:Discharge_Air_Temperature_Heating_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Heating,Sets temperature of discharge air for heating +brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Step, +brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:Velocity,brick:Sensor,Pressure, +brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. +brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water +brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water,,,brick:Command,System Enable,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water +brick:Drive_Ready_Status,,,,,,brick:Status,Drive Ready,"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" +brick:Duct_Air_Static_Pressure_Setpoint,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, +brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event +brick:EconCycle_Start_Stop_Status,,,,,,brick:Status,EconCycle Start Stop, +brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Effective, +brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Cooling,The effective cooling setpoint for a specific zone in a building. +brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Effective, +brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Heating,The effective heating setpoint for a specific zone in a building. +brick:Effective_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Effective, +brick:Effective_Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Effective Room, +brick:Effective_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Effective, +brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width +brick:Electric_Energy_Sensor,,,,,,brick:Sensor,Electric Energy, +brick:Electric_Power_Sensor,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed +brick:Electrical_Energy_Usage_Sensor,,,,,,brick:Sensor,Electrical Energy Usage,A sensor that records the quantity of electrical energy consumed in a given period +brick:Embedded_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. +brick:Embedded_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." +brick:Emergency_Air_Flow_System_Status,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Status,Emergency System, +brick:Emergency_Alarm,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Generator_Alarm,,,,,,brick:Alarm,Emergency Generator,An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,,,,,brick:Status,Emergency Generator,Indicates if an emergency generator is active +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,quantitykind:Power,brick:Status,Emergency Off System Activated By High Temperature, +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,quantitykind:Power,brick:Status,Emergency Off System Activated By Leak Detection, +brick:Emergency_Power_Off_System_Status,,,,,quantitykind:Power,brick:Status,Emergency Off System, +brick:Emergency_Push_Button_Status,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed +brick:Enable_Command,,,,,,brick:Command,Enable,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Enable,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Command,Enable,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Command,Enable Fixed,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Command,Enable Fixed,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Enable System Outside Air,Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,brick:Status,Enable,Indicates if a system or piece of functionality has been enabled +brick:Energy_Generation_Sensor,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. +brick:Energy_Sensor,,,,,,brick:Sensor,Energy,Measures energy consumption +brick:Energy_Usage_Sensor,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time +brick:Entering_Chilled_Water_Flow_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water +brick:Entering_Chilled_Water_Flow_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water +brick:Entering_Chilled_Water_Temperature_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower +brick:Entering_Chilled_Water_Temperature_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water +brick:Entering_Condenser_Water_Flow_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Setpoint,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water +brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering, +brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering, +brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering High Temperature,Measures the temperature of high-temperature hot water enteringed to a hot water system +brick:Entering_Hot_Water_Flow_Sensor,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water +brick:Entering_Hot_Water_Flow_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water +brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,Load Shed, +brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Entering_Hot_Water_Temperature_Sensor,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system +brick:Entering_Hot_Water_Temperature_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering Medium Temperature High, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering Medium Temperature Load Shed, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Hot_Water,,quantitykind:Temperature,brick:Status,Entering Medium Temperature Load Shed, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering Medium Temperature Low, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering Medium Temperature,Measures the temperature of medium-temperature hot water entering a hot water system +brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water +brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Entering_Water_Flow_Sensor,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system +brick:Entering_Water_Flow_Setpoint,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water +brick:Entering_Water_Pressure_Sensor,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. +brick:Entering_Water_Temperature_Alarm,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. +brick:Entering_Water_Temperature_Deadband_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water +brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Parameter,Integral Time, +brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water +brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water +brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance +brick:Enthalpy_Setpoint,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy +brick:Even_Month_Status,,,,,,brick:Status,Even Month, +brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air +brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building +brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit +brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Integral Time, +brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Proportional Band, +brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air +brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate +brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,,brick:Sensor,Humidity,Measures the relative humidity of exhaust air +brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,,brick:Setpoint,Humidity,Humidity setpoint for exhaust air +brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Stack Integral Time, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Stack Proportional Band, +brick:Exhaust_Air_Stack_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack +brick:Exhaust_Air_Stack_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate +brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system +brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air +brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air +brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:Velocity,brick:Sensor,Pressure, +brick:Failure_Alarm,,,,,,brick:Alarm,Failure,"Alarms that indicate the failure of devices, equipment, systems and control loops" +brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans +brick:Fan_On_Off_Status,,brick:Fan,,,,brick:Status,On Off, +brick:Fan_Speed_Command,,brick:Fan,,,,brick:Command,Speed,Controls the speed of fans +brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans +brick:Fault_Reset_Command,,,,,,brick:Command,Fault Reset,Clears a fault status +brick:Fault_Status,,,,,,brick:Status,Fault,"Indicates the presence of a fault in a device, system or control loop" +brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. +brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter +brick:Filter_Reset_Command,,brick:Filter,,,,brick:Command,Reset, +brick:Filter_Status,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced +brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. +brick:Fire_Sensor,,,,,,brick:Sensor,Fire,Measures the presence of fire +brick:Flow_Sensor,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance +brick:Flow_Setpoint,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow +brick:Formaldehyde_Level_Sensor,,,,,,brick:Sensor,Formaldehyde Level,Measures the concentration of formaldehyde in air +brick:Freeze_Status,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen +brick:Frequency_Command,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) +brick:Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" +brick:Frequency_Setpoint,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency +brick:Fresh_Air_Setpoint_Limit,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Frost_Sensor,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost +brick:Fume_Hood_Air_Flow_Sensor,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood +brick:Gain_Parameter,,,,,,brick:Parameter,Gain, +brick:Gas_Sensor,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) +brick:Gauge_Pressure_Sensor,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure +brick:Generation_Sensor,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. +brick:Hail_Sensor,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential +brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger,,,,brick:Status,System Enable,Indicates if the heat exchanger system has been enabled +brick:Heat_Sink_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. +brick:Heating_Command,,,,,,brick:Command,Heating,Controls the amount of heating to be delivered (typically as a proportion of total heating output) +brick:Heating_Demand_Sensor,,,,,,brick:Sensor,Heating Demand,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Heating_Demand_Setpoint,,,,,,brick:Setpoint,Heating Demand,Sets the rate required for heating +brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets discharge air flow for heating +brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of heating discharge air +brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Heating Integral Time, +brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Heating Proportional Band, +brick:Heating_Enable_Command,,,,,,brick:Command,Heating Enable,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Mode_Status,,,,,,brick:Status,Heating Mode,"Indicates whether a system, device or control loop is in a heating mode" +brick:Heating_Start_Stop_Status,,,,,,brick:Status,Heating Start Stop, +brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets supply air flow rate for heating +brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of supply air for heating +brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Heating Integral Time, +brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Heating Proportional Band, +brick:Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Heating,Sets temperature for heating +brick:Heating_Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Heating Thermal, +brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Heating,The heating setpoint for a specific zone in a building. +brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,High,An alarm that indicates that the air flow is higher than normal. +brick:High_CO2_Alarm,,,brick:CO2,,,brick:Alarm,High,A device that indicates high concentration of carbon dioxide. +brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates that discharge air temperature is too high +brick:High_Head_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,High Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Humidity_Alarm,,,,,,brick:Alarm,High Humidity,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,,,,,,brick:Alarm_Parameter,High Humidity,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,High Lockout,The upper bound of the outside air temperature lockout range +brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates that return air temperature is too high +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,High Cutout,A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. +brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,High, +brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates high temperature. +brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Parameter,High,A parameter determining the temperature level at which to trigger a high temperature alarm +brick:Hold_Status,,,,,,brick:Status,Hold, +brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water +brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, +brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, +brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve +brick:Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water +brick:Hot_Water_Differential_Temperature_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device +brick:Hot_Water_Flow_Sensor,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit +brick:Hot_Water_Flow_Setpoint,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water +brick:Hot_Water_Gauge_Pressure_Sensor,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water +brick:Hot_Water_Static_Pressure_Setpoint,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air +brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water,,,brick:Command,System Enable,Enables operation of the hot water system +brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water +brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" +brick:Humidification_Start_Stop_Status,,,,,,brick:Status,Humidification Start Stop, +brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Status,Fault,Indicates the presence of a fault in a humidifier +brick:Humidify_Command,,,,,,brick:Command,Humidify, +brick:Humidity_Alarm,,,,,,brick:Alarm,Humidity,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. +brick:Humidity_Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,Humidity,Sets the size of a deadband of humidity +brick:Humidity_Parameter,,,,,,brick:Parameter,Humidity,Parameters relevant to humidity-related systems and points +brick:Humidity_Sensor,,,,,,brick:Sensor,Humidity,Measures the concentration of water vapor in air +brick:Humidity_Setpoint,,,,,,brick:Setpoint,Humidity,Sets humidity +brick:Humidity_Tolerance_Parameter,,,,,,brick:Parameter,Humidity Tolerance,A parameter determining the difference between upper and lower limits of humidity. +brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Tank,brick:Ice,,quantitykind:Temperature,brick:Sensor,Leaving Water,Measures the temperature of water leaving an ice tank +brick:Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" +brick:Illuminance_Setpoint,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. +brick:Imbalance_Sensor,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system +brick:Inside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. +brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. +brick:Intake_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Intake,Measures air at the interface between the building and the outside +brick:Integral_Gain_Parameter,,,,,,brick:Parameter,Integral Gain, +brick:Integral_Time_Parameter,,,,,,brick:Parameter,Integral Time, +brick:Last_Fault_Code_Status,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred +brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation +brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled +brick:Lead_On_Off_Command,,,,,,brick:Command,Lead On Off,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" +brick:Leak_Alarm,,,,,,brick:Alarm,Leak,An alarm that indicates leaks occured in systems containing fluids +brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water +brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water +brick:Leaving_Chilled_Water_Temperature_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller +brick:Leaving_Chilled_Water_Temperature_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water +brick:Leaving_Condenser_Water_Flow_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Setpoint,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water +brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of domestic water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving,Sets temperature of leavinging part of domestic hot water +brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving High Temperature,Measures the temperature of high-temperature hot water supplied by a hot water system +brick:Leaving_Hot_Water_Flow_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water +brick:Leaving_Hot_Water_Flow_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water +brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,Load Shed, +brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Leaving_Hot_Water_Temperature_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system +brick:Leaving_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving Medium Temperature High, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving Medium Temperature Load Shed, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Hot_Water,,quantitykind:Temperature,brick:Status,Leaving Medium Temperature Load Shed, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving Medium Temperature Low, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving Medium Temperature,Measures the temperature of medium-temperature hot water supplied by a hot water system +brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water +brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Leaving_Water_Flow_Sensor,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system +brick:Leaving_Water_Flow_Setpoint,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water +brick:Leaving_Water_Pressure_Sensor,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. +brick:Leaving_Water_Temperature_Alarm,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. +brick:Leaving_Water_Temperature_Deadband_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water +brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Parameter,Integral Time, +brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system +brick:Leaving_Water_Temperature_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water +brick:Level_Command,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. +brick:Level_Status,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. +brick:Lighting_Correlated_Color_Temperature_Command,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Correlated_Color_Temperature_Sensor,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Level_Command,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. +brick:Limit,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point +brick:Liquid_Detection_Alarm,,,brick:Liquid,,,brick:Alarm,Detection, +brick:Load_Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load +brick:Load_Parameter,,,,,,brick:Parameter,Load, +brick:Load_Setpoint,,,,,,brick:Setpoint,Load, +brick:Load_Shed_Command,,,,,,brick:Command,Load Shed,Controls load shedding behavior provided by a control system +brick:Load_Shed_Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,Load Shed, +brick:Load_Shed_Setpoint,,,,,,brick:Setpoint,Load Shed, +brick:Load_Shed_Status,,,,,,brick:Status,Load Shed,Indicates if a load shedding policy is in effect +brick:Locally_On_Off_Status,,,,,,brick:Status,Locally On Off, +brick:Lockout_Status,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low,An alarm that indicates that the air flow is lower than normal. +brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Alarm,Low,An alarm that indicates the battery is low. +brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low,An alarm that indicates that the discharge air flow is lower than normal. +brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,Low, +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Low Freeze Protect, +brick:Low_Humidity_Alarm,,,,,,brick:Alarm,Low Humidity,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,,,,,,brick:Alarm_Parameter,Low Humidity,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Low Lockout,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Low Enable, +brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Low Enable, +brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,Low,An alarm that indicates that return air temperature is too low +brick:Low_Suction_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,Low Suction,An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low, +brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,Low, +brick:Low_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,Low,An alarm that indicates low temperature. +brick:Low_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Parameter,Low,A parameter determining the temperature level at which to trigger a low temperature alarm +brick:Low_Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,Low,An alarm that indicates the voltage is lower than its normal state. +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,Lowest,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Luminance_Alarm,,,,,quantitykind:Luminance,brick:Alarm,, +brick:Luminance_Command,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system +brick:Luminance_Sensor,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction +brick:Luminance_Setpoint,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance +brick:Maintenance_Mode_Command,,,,,,brick:Command,Maintenance Mode,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" +brick:Maintenance_Required_Alarm,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Manual_Auto_Status,,,,,,brick:Status,Manual Auto,Indicates if a system is under manual or automatic operation +brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Max_Air_Temperature_Setpoint,brick:Maximum,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature +brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Max_Discharge_Air_Temperature_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Max_Frequency_Command,brick:Maximum,,,,quantitykind:Frequency,brick:Command,,Sets the maximum permitted frequency +brick:Max_Fresh_Air_Setpoint_Limit,brick:Maximum,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Max_Limit,brick:Maximum,,,,,brick:Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. +brick:Max_Load_Setpoint,brick:Maximum,,,,,brick:Setpoint,Load, +brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Outside_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Max_Position_Setpoint_Limit,brick:Maximum,,,,,brick:Setpoint_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. +brick:Max_Speed_Setpoint_Limit,brick:Maximum,,,,,brick:Setpoint_Limit,Speed,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Static_Pressure_Setpoint_Limit,brick:Maximum,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Max_Supply_Air_Temperature_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Max_Temperature_Setpoint_Limit,brick:Maximum,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. +brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Water_Level_Alarm,brick:Maximum,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the maximum water level was reached +brick:Max_Water_Temperature_Setpoint,brick:Maximum,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for max water temperature +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Status,Medium Pressure Load Shed Reset, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,Medium Pressure Load Shed, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Status,Medium Pressure Load Shed, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Medium Pressure,Measures the difference in water pressure between sections of a medium temperature hot water system +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,Medium Pressure, +brick:Methane_Level_Sensor,,,,,,brick:Sensor,Methane Level,Measures the concentration of methane in air +brick:Min_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Min_Air_Temperature_Setpoint,brick:Minimum,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for minimum air temperature +brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Min_Discharge_Air_Temperature_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Min_Frequency_Command,brick:Minimum,,,,quantitykind:Frequency,brick:Command,, +brick:Min_Fresh_Air_Setpoint_Limit,brick:Minimum,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Min_Limit,brick:Minimum,,,,,brick:Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. +brick:Min_Load_Setpoint,brick:Minimum,,,,,brick:Setpoint,Load, +brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Outside_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Min_Position_Setpoint_Limit,brick:Minimum,,,,,brick:Setpoint_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. +brick:Min_Speed_Setpoint_Limit,brick:Minimum,,,,,brick:Setpoint_Limit,Speed,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Static_Pressure_Setpoint_Limit,brick:Minimum,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Min_Supply_Air_Temperature_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Min_Temperature_Setpoint_Limit,brick:Minimum,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. +brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Water_Level_Alarm,brick:Minimum,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the minimum water level was reached +brick:Min_Water_Temperature_Setpoint,brick:Minimum,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for min water temperature +brick:Mixed_Air_Flow_Sensor,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air +brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,,brick:Sensor,Humidity,Measures the humidity of mixed air +brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,,brick:Setpoint,Humidity,Humidity setpoint for mixed air +brick:Mixed_Air_Temperature_Sensor,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air +brick:Mixed_Air_Temperature_Setpoint,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air +brick:Mode_Command,,,,,,brick:Command,Mode,Controls the operating mode of a device or controller +brick:Mode_Status,,,,,,brick:Status,Mode,"Indicates which mode a system, device or control loop is currently in" +brick:Motion_Sensor,,,,,,brick:Sensor,Motion,Detects the presence of motion in some area +brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor +brick:Motor_Direction_Status,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" +brick:Motor_On_Off_Status,,brick:Motor,,,,brick:Status,On Off, +brick:Motor_Speed_Sensor,,brick:Motor,,,,brick:Sensor,Speed, +brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" +brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas +brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas +brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" +brick:No_Water_Alarm,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system +brick:NO2_Level_Sensor,,,,,,brick:Sensor,NO2 Level,Measures the concentration of NO2 in air +brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" +brick:Occupancy_Count_Sensor,,,,,,brick:Sensor,Occupancy Count,Sensors measuring the number of people in an area +brick:Occupancy_Sensor,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area +brick:Occupancy_Status,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied +brick:Occupied_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Occupied, +brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Cooling,Sets discharge air flow for cooling when occupied +brick:Occupied_Cooling_Mode_Status,,,,,,brick:Status,Occupied Cooling Mode, +brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Cooling,Sets supply air flow rate for cooling when occupied +brick:Occupied_Cooling_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Occupied Cooling,Sets the size of a deadband of temperature for cooling when occupied +brick:Occupied_Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Occupied Cooling,Sets temperature for cooling when occupied +brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Cooling,Sets temperature for zone air cooling when occupied +brick:Occupied_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied,Sets discharge air flow when occupied +brick:Occupied_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, +brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Heating,Sets discharge air flow for heating when occupied +brick:Occupied_Heating_Mode_Status,,,,,,brick:Status,Occupied Heating Mode, +brick:Occupied_Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Heating,Sets supply air flow rate for heating when occupied +brick:Occupied_Heating_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Occupied Heating,Sets the size of a deadband of temperature for heating when occupied +brick:Occupied_Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Occupied Heating,Sets temperature for heating when occupied +brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Heating,Sets temperature for zone air heating when occupied +brick:Occupied_Humidity_Setpoint,,,,,,brick:Setpoint,Occupied Humidity,Target humidity level when the location is occupied. +brick:Occupied_Load_Shed_Command,,,,,,brick:Command,Occupied Load Shed, +brick:Occupied_Mode_Status,,,,,,brick:Status,Occupied Mode,"Indicates if a system, device or control loop is in ""Occupied"" mode" +brick:Occupied_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, +brick:Occupied_Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Occupied Room, +brick:Occupied_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied,Sets supply air flow rate when occupied +brick:Occupied_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, +brick:Occupied_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Off_Command,,,,,,brick:Command,Off,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" +brick:Off_Status,,,,,,brick:Status,Off,"Indicates if a control loop, relay or equipment is off" +brick:On_Command,,,,,,brick:Command,On,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" +brick:On_Off_Command,,,,,,brick:Command,On Off,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" +brick:On_Off_Status,,,,,,brick:Status,On Off,"Indicates the on/off status of a control loop, relay or equipment" +brick:On_Status,,,,,,brick:Status,On,"Indicates if a control loop, relay or equipment is on" +brick:On_Timer_Sensor,,,,,,brick:Sensor,On Timer,"Measures the duration for which a device was in an active or ""on"" state" +brick:Open_Close_Command,,,,,,brick:Command,Open Close,"A binary signal given to a device, such as a damper or valve, to either open or close" +brick:Open_Close_Status,,,,,,brick:Status,Open Close,Indicates the open/close status of a device such as a damper or valve +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, +brick:Operating_Mode_Status,,,,,,brick:Status,Operating Mode,"Indicates the current operating mode of a system, device or control loop" +brick:Output_Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,Output, +brick:Output_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device +brick:Outside_Air_CO_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air +brick:Outside_Air_CO2_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air +brick:Outside_Air_Dewpoint_Sensor,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air +brick:Outside_Air_Enthalpy_Sensor,,,brick:Outside_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air +brick:Outside_Air_Flow_Sensor,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system +brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate +brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air +brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,,brick:Sensor,Humidity,Measures the relative humidity of outside air +brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,,brick:Setpoint,Humidity,Humidity setpoint for outside air +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, +brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air +brick:Outside_Air_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air +brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air +brick:Outside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. +brick:Outside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. +brick:Outside_Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" +brick:Overload_Alarm,,,,,,brick:Alarm,Overload,An alarm that can indicate when a full-load current is exceeded. +brick:Overridden_Off_Status,,,,,,brick:Status,Overridden Off,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" +brick:Overridden_On_Status,,,,,,brick:Status,Overridden On,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" +brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden +brick:Override_Command,,,,,,brick:Command,Override,Controls or reports whether or not a device or control loop is in 'override' +brick:Ozone_Level_Sensor,,,,,,brick:Sensor,Ozone Level,Measures the concentration of ozone in air +brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values +brick:Particulate_Matter_Sensor,,,,,,brick:Sensor,Particulate Matter,Detects pollutants in the ambient air +brick:Peak_Demand_Sensor,,,,,,brick:Sensor,Peak Demand,The peak power consumed by a process over some period of time +brick:Photovoltaic_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Photovoltaic Output,Senses the amperes of electrical current produced as output by a photovoltaic device +brick:PID_Parameter,,,,,,brick:Parameter,PID, +brick:Piezoelectric_Sensor,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:PM1_Level_Sensor,,,,,,brick:Sensor,PM1 Level,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,,,,brick:Sensor,PM1,Detects matter of size 1 micron +brick:PM10_Level_Sensor,,,,,,brick:Sensor,PM10 Level,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,,,,brick:Sensor,PM10,Detects matter of size 10 microns +brick:PM2.5_Level_Sensor,,,,,,brick:Sensor,PM2.5 Level,Detects level of particulates of size 2.5 microns +brick:PM2.5_Sensor,,,,,,brick:Sensor,PM2.5,Detects matter of size 2.5 microns +brick:Position_Command,,,,,,brick:Command,Position,Controls or reports the position of some object +brick:Position_Limit,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. +brick:Position_Sensor,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion +brick:Power_Alarm,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. +brick:Power_Factor_Sensor,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." +brick:Power_Loss_Alarm,,,,,quantitykind:Power,brick:Alarm,Loss,An alarm that indicates a power failure. +brick:Power_Sensor,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed +brick:Pre_Filter_Status,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced +brick:Preheat_Command,,,,,,brick:Command,Preheat,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer +brick:Preheat_Demand_Setpoint,,,,,,brick:Setpoint,Preheat Demand,Sets the rate required for preheat +brick:Preheat_Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of discharge air before heating is applied +brick:Preheat_Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of supply air before it is heated +brick:Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. +brick:Pressure_Sensor,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area +brick:Pressure_Setpoint,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure +brick:Pressure_Status,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds +brick:Proportional_Band_Parameter,,,,,,brick:Parameter,Proportional Band, +brick:Proportional_Gain_Parameter,,,,,,brick:Parameter,Proportional Gain, +brick:Pump_Command,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) +brick:Pump_On_Off_Status,,brick:Pump,,,,brick:Status,On Off, +brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump +brick:PV_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,PV Output,See Photovoltaic_Current_Output_Sensor +brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. +brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. +brick:Radon_Concentration_Sensor,,,,,,brick:Sensor,Radon Concentration,Measures the concentration of radioactivity due to radon +brick:Rain_Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame +brick:Rain_Level_Sensor,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen +brick:Rated_Speed_Setpoint,,,,,,brick:Setpoint,Rated Speed,Sets rated speed +brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power +brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" +brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, +brick:Reheat_Command,,,,,,brick:Command,Reheat,"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature +brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay +brick:Remotely_On_Off_Status,,,,,,brick:Status,Remotely On Off, +brick:Reset_Command,,,,,,brick:Command,Reset,"Commands that reset a flag, property or value to its default" +brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies +brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air +brick:Return_Air_CO2_Sensor,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air +brick:Return_Air_CO2_Setpoint,,,brick:Return_Air,,,brick:Setpoint,CO2,Sets some property of CO2 in Return Air +brick:Return_Air_Dewpoint_Sensor,,,brick:Return_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air +brick:Return_Air_Differential_Pressure_Sensor,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side +brick:Return_Air_Differential_Pressure_Setpoint,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit +brick:Return_Air_Enthalpy_Sensor,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air +brick:Return_Air_Flow_Sensor,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air +brick:Return_Air_Grains_Sensor,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air +brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,,brick:Sensor,Humidity,Measures the relative humidity of return air +brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,,brick:Setpoint,Humidity,Humidity setpoint for return air +brick:Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. +brick:Return_Air_Temperature_High_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Return_Air_Temperature_Low_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Return_Air_Temperature_Sensor,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air +brick:Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" +brick:Room_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Room, +brick:Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Room,Sets temperature of room air +brick:Run_Enable_Command,,,,,,brick:Command,Run Enable, +brick:Run_Request_Status,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment +brick:Run_Status,,,,,,brick:Status,Run, +brick:Run_Time_Sensor,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" +brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule +brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). +brick:Sensor_Failure_Alarm,,,,,,brick:Alarm,Sensor Failure, +brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set +brick:Short_Cycle_Alarm,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Smoke_Alarm,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. +brick:Smoke_Detection_Alarm,,,,,,brick:Alarm,Smoke Detection, +brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil +brick:Solar_Azimuth_Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,Solar Azimuth,Measures the azimuth angle of the sun +brick:Solar_Irradiance_Sensor,,,,,,brick:Sensor,Solar Irradiance,Measures solar irradiance levels for photovoltaic systems +brick:Solar_Zenith_Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,Solar Zenith,Measures the zenith angle of the sun +brick:Speed_Command,,,,,,brick:Command,Speed,A command to set speed to a certain degree. +brick:Speed_Mode_Status,,,,,,brick:Status,Speed Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Reset_Command,,,,,,brick:Command,Speed Reset, +brick:Speed_Sensor,,,,,,brick:Sensor,Speed,Measures the magnitude of velocity of some form of movement +brick:Speed_Setpoint,,,,,,brick:Setpoint,Speed,Sets speed +brick:Speed_Setpoint_Limit,,,,,,brick:Setpoint_Limit,Speed,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. +brick:Stage_Enable_Command,,,,,,brick:Command,Stage Enable,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in +brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Cooling, +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,brick:Status,Standby Glycool Unit On Off,Indicates the on/off status of a standby glycool unit +brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Heating, +brick:Standby_Load_Shed_Command,,,,,,brick:Command,Standby Load Shed, +brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, +brick:Standby_Unit_On_Off_Status,,,,,,brick:Status,Standby Unit On Off,Indicates the on/off status of a standby unit +brick:Start_Stop_Command,,,,,,brick:Command,Start Stop,A Start/Stop Command controls or reports the active/inactive status of a control sequence +brick:Start_Stop_Status,,,,,,brick:Status,Start Stop,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) +brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure +brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Parameter,Integral Time, +brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Static_Pressure_Sensor,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work +brick:Static_Pressure_Setpoint,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure +brick:Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Status,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" +brick:Steam_On_Off_Command,,,brick:Steam,,,brick:Command,On Off, +brick:Steam_Usage_Sensor,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" +brick:Step_Parameter,,,,,,brick:Parameter,Step, +brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, +brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building +brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit +brick:Supply_Air_Duct_Pressure_Status,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds +brick:Supply_Air_Flow_Demand_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of supply air flow required for a process +brick:Supply_Air_Flow_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,High, +brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,Low, +brick:Supply_Air_Flow_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air +brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate +brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,,brick:Sensor,Humidity,Measures the relative humidity of supply air +brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,,brick:Setpoint,Humidity,Humidity setpoint for supply air +brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, +brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Parameter,Proportional Gain, +brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Supply_Air,,,brick:Alarm,Smoke Detection, +brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air +brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Parameter,Integral Time, +brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Supply_Air_Static_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system +brick:Supply_Air_Static_Pressure_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air +brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. +brick:Supply_Air_Temperature_Cooling_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Cooling, +brick:Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air +brick:Supply_Air_Temperature_Heating_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Heating, +brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air +brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air +brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Step, +brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:Velocity,brick:Sensor,Pressure, +brick:Switch_Status,,brick:Switch,,,,brick:Status,,Status of a switch +brick:System_Enable_Command,,,,,,brick:Command,System Enable,Enables operation of a system +brick:System_Shutdown_Status,,,,,,brick:Status,System Shutdown,Indicates if a system has been shutdown +brick:System_Status,,,,,,brick:Status,System,Indicates properties of the activity of a system +brick:Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, +brick:Temperature_Adjust_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Adjust,Measures user-provided adjustment of temperature +brick:Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. +brick:Temperature_Alarm_Sensitivity_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a temperature alarm. +brick:Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature +brick:Temperature_Differential_Reset_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_High_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Reset_Setpoint,High, +brick:Temperature_Low_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Reset_Setpoint,Low, +brick:Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points +brick:Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold +brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature +brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Step, +brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Tolerance,A parameter determining the difference between upper and lower limits of temperature. +brick:Temporary_Occupancy_Status,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Thermal_Energy_Usage_Sensor,,,,,,brick:Sensor,Thermal Energy Usage,A sensor that records the quantity of thermal energy consumed in a given period +brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat +brick:Time_Parameter,,,,,,brick:Parameter,Time, +brick:Time_Setpoint,,,,,,brick:Setpoint,Time, +brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. +brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." +brick:Tolerance_Parameter,,,,,,brick:Parameter,Tolerance,difference between upper and lower limits of size for a given nominal dimension or value. +brick:Torque_Sensor,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" +brick:TVOC_Level_Sensor,,,,,,brick:Sensor,TVOC Level,A sensor measuring the level of all VOCs in air +brick:TVOC_Sensor,,,,,,brick:Sensor,TVOC, +brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum +brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure +brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air +brick:Unit_Failure_Alarm,,,,,,brick:Alarm,Unit Failure,An alarm that indicates the failure of an equipment or device +brick:Unoccupied_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied,Sets temperature of air when unoccupied +brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Cooling,Sets discharge air flow for cooling when unoccupied +brick:Unoccupied_Cooling_Mode_Status,,,,,,brick:Status,Unoccupied Cooling Mode,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" +brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Cooling, +brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Unoccupied Cooling, +brick:Unoccupied_Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Unoccupied Cooling, +brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Cooling,Sets temperature of air when unoccupied for cooling within a specific zone +brick:Unoccupied_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied, +brick:Unoccupied_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, +brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Heating, +brick:Unoccupied_Heating_Mode_Status,,,,,,brick:Status,Unoccupied Heating Mode,"Indicates whether a system, device or control loop is in an unoccupied heating mode" +brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Heating, +brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Unoccupied Heating, +brick:Unoccupied_Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Unoccupied Heating, +brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Heating,Sets temperature of air when unoccupied for heating within a specific zone +brick:Unoccupied_Humidity_Setpoint,,,,,,brick:Setpoint,Unoccupied Humidity,Target humidity level when the location is unoccupied. +brick:Unoccupied_Load_Shed_Command,,,,,,brick:Command,Unoccupied Load Shed, +brick:Unoccupied_Mode_Status,,,,,,brick:Status,Unoccupied Mode, +brick:Unoccupied_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, +brick:Unoccupied_Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Room, +brick:Unoccupied_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied, +brick:Unoccupied_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, +brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Usage_Sensor,,,,,,brick:Sensor,Usage,"Measures the amount of some substance that is consumed or used, over some period of time" +brick:Valve_Command,,brick:Valve,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) +brick:Valve_Position_Alarm,,brick:Valve,,,,brick:Alarm,Position,An alarm that indicates that the valve position is not in a normal state. +brick:Valve_Position_Command,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve +brick:Valve_Position_Sensor,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open +brick:Valve_Status,,brick:Valve,,,,brick:Status,,The current status of the valve. +brick:Velocity_Pressure_Sensor,,,,,quantitykind:Velocity,brick:Sensor,Pressure,Measures the difference between total pressure and static pressure +brick:Velocity_Pressure_Setpoint,,,,,quantitykind:Velocity,brick:Setpoint,Pressure,Sets static veloicty pressure +brick:Vent_Operating_Mode_Status,,,,,,brick:Status,Vent Operating Mode,Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:VFD_Enable_Command,,brick:VFD,,,,brick:Command,Enable,Enables operation of a variable frequency drive +brick:Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. +brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system +brick:Voltage_Ratio_Setpoint,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer +brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object +brick:Warm_Cool_Adjust_Sensor,,,,,,brick:Sensor,Warm Cool Adjust,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warmest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Warmest,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Waste_Amount_Sensor,,,,,,brick:Sensor,Waste Amount,A metric used for measuring the quantity of waste generated in a building. +brick:Water_Alarm,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" +brick:Water_Differential_Pressure_Sensor,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. +brick:Water_Differential_Pressure_Setpoint,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit +brick:Water_Differential_Temperature_Sensor,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit +brick:Water_Differential_Temperature_Setpoint,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit +brick:Water_Flow_Sensor,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water +brick:Water_Flow_Setpoint,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water +brick:Water_Level_Alarm,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin +brick:Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container +brick:Water_Loss_Alarm,,,brick:Water,,,brick:Alarm,Loss,An alarm that indicates a loss of water e.g. during transport +brick:Water_Pressure_Sensor,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. +brick:Water_Pressure_Setpoint,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, +brick:Water_Temperature_Alarm,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. +brick:Water_Temperature_Sensor,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water +brick:Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water +brick:Water_Usage_Sensor,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" +brick:Wind_Direction_Sensor,,,,,,brick:Sensor,Wind Direction,Measures the direction of wind in degrees relative to North +brick:Wind_Speed_Sensor,,,,,,brick:Sensor,Wind Speed,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,,brick:Status,Conditioning Mode,Indicates the mode of AC for a zone +brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air +brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,,brick:Sensor,Humidity,Measures the relative humidity of zone air +brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,,brick:Setpoint,Humidity,Humidity setpoint for zone air +brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone +brick:Zone_CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone +brick:Zone_Occupied_Load_Shed_Command,,,,,,brick:Command,Zone Occupied Load Shed, +brick:Zone_Standby_Load_Shed_Command,,,,,,brick:Command,Zone Standby Load Shed, +brick:Zone_Unoccupied_Load_Shed_Command,,,,,,brick:Command,Zone Unoccupied Load Shed, From 67f0fe4dc17e33260c5627b8ef30422ee092ad84 Mon Sep 17 00:00:00 2001 From: ektrah Date: Mon, 18 Aug 2025 08:57:54 +0200 Subject: [PATCH 02/31] Add new substance: Ammonia [no ci] --- bricksrc/definitions.csv | 2 ++ bricksrc/points.csv | 2 +- bricksrc/substances.py | 1 + 3 files changed, 4 insertions(+), 1 deletion(-) diff --git a/bricksrc/definitions.csv b/bricksrc/definitions.csv index d74beafd..41e7ba20 100644 --- a/bricksrc/definitions.csv +++ b/bricksrc/definitions.csv @@ -41,6 +41,8 @@ https://brickschema.org/schema/Brick#Alarm,Alarm points are signals (either audi https://brickschema.org/schema/Brick#Alarm_Delay_Parameter,A parameter determining how long to delay an alarm after sufficient conditions have been met, https://brickschema.org/schema/Brick#Alarm_Sensitivity_Parameter,A parameter indicates the sensitivity to activate an alarm., https://brickschema.org/schema/Brick#Alternating_Current_Frequency,The frequency of the oscillations of alternating current, +https://brickschema.org/schema/Brick#Ammonia,A colorless gas with a distinctive pungent smell, +https://brickschema.org/schema/Brick#Ammonia_Sensor,Measures the concentration of ammonia in air, https://brickschema.org/schema/Brick#Angle_Sensor,Measues the planar angle of some phenomenon, https://brickschema.org/schema/Brick#Atrium,a large open-air or skylight covered space surrounded by a building.,https://en.wikipedia.org/wiki/Atrium_(architecture) https://brickschema.org/schema/Brick#Audio_Visual_Equipment,Equipment related to sound and visual components such as speakers and displays., diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 60d2b390..f366cadc 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -31,7 +31,7 @@ brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperatu brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action brick:Alarm_Delay_Parameter,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met brick:Alarm_Sensitivity_Parameter,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. -brick:Ammonia_Sensor,,,,,,brick:Sensor,Ammonia, +brick:Ammonia_Sensor,,,brick:Ammonia,,,brick:Sensor,,Measures the concentration of ammonia in air brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon brick:Automatic_Mode_Command,,,,,,brick:Command,Automatic Mode,"Controls whether or not a device or controller is operating in ""Automatic"" mode" brick:Availability_Status,,,,,,brick:Status,Availability,"Indicates if a piece of equipment, system, or functionality is available for operation" diff --git a/bricksrc/substances.py b/bricksrc/substances.py index 0a5af83e..8e4831ee 100644 --- a/bricksrc/substances.py +++ b/bricksrc/substances.py @@ -27,6 +27,7 @@ }, }, }, + "Ammonia": {}, "CO2": {}, "CO": {}, "Steam": {}, From 69b9dbe31eb9fe16134536b7728b448f63031bdd Mon Sep 17 00:00:00 2001 From: ektrah Date: Mon, 18 Aug 2025 09:33:52 +0200 Subject: [PATCH 03/31] Use Deionized_Water spelling consistently [no ci] --- bricksrc/definitions.csv | 4 ++-- bricksrc/points.csv | 4 ++-- bricksrc/sensor.py | 6 ++++-- 3 files changed, 8 insertions(+), 6 deletions(-) diff --git a/bricksrc/definitions.csv b/bricksrc/definitions.csv index 41e7ba20..5d958526 100644 --- a/bricksrc/definitions.csv +++ b/bricksrc/definitions.csv @@ -240,8 +240,8 @@ https://brickschema.org/schema/Brick#Deceleration_Time,, https://brickschema.org/schema/Brick#Deceleration_Time_Setpoint,, https://brickschema.org/schema/Brick#Dedicated_Outdoor_Air_System_Unit,"A device that conditions and delivers 100% outdoor air to its assigned spaces. It decouples air-conditioning of the outdoor air, usually used to provide minimum outdoor air ventilation, from conditioning of the internal loads.", https://brickschema.org/schema/Brick#Dehumidify_Command,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels", -https://brickschema.org/schema/Brick#Deionised_Water_Conductivity_Sensor,Measures the electrical conductance of deionised water, -https://brickschema.org/schema/Brick#Deionised_Water_Level_Sensor,Measures the height/level of deionised water in some container, +https://brickschema.org/schema/Brick#Deionized_Water_Conductivity_Sensor,Measures the electrical conductance of deionized water, +https://brickschema.org/schema/Brick#Deionized_Water_Level_Sensor,Measures the height/level of deionized water in some container, https://brickschema.org/schema/Brick#Deionized_Water,Water which has been purified by removing its ions (constituting the majority of non-particulate contaminants), https://brickschema.org/schema/Brick#Deionized_Water_Alarm,An alarm that indicates deionized water leaks., https://brickschema.org/schema/Brick#Delay_Parameter,A parameter determining how long to delay a subsequent action to take place after a received signal, diff --git a/bricksrc/points.csv b/bricksrc/points.csv index f366cadc..05e1e24c 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -128,9 +128,9 @@ brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadban brick:Deceleration_Time_Setpoint,,,,,,brick:Setpoint,Deceleration Time, brick:Dehumidification_Start_Stop_Status,,,,,,brick:Status,Dehumidification Start Stop, brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" -brick:Deionised_Water_Conductivity_Sensor,,,brick:Water,,quantitykind:Conductivity,brick:Sensor,Deionised,Measures the electrical conductance of deionised water -brick:Deionised_Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Deionised Level,Measures the height/level of deionised water in some container brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. +brick:Deionized_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water +brick:Deionized_Water_Level_Sensor,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container brick:Delay_Parameter,,,,,,brick:Parameter,Delay,A parameter determining how long to delay a subsequent action to take place after a received signal brick:Demand_Sensor,,,,,,brick:Sensor,Demand,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Demand_Setpoint,,,,,,brick:Setpoint,Demand,Sets the rate required for a process diff --git a/bricksrc/sensor.py b/bricksrc/sensor.py index 3bf166a6..6a4b2649 100644 --- a/bricksrc/sensor.py +++ b/bricksrc/sensor.py @@ -329,7 +329,8 @@ "tags": [TAG.Point, TAG.Sensor, TAG.Conductivity], BRICK.hasQuantity: QUDTQK.Conductivity, "subclasses": { - "Deionised_Water_Conductivity_Sensor": { + "Deionized_Water_Conductivity_Sensor": { + "aliases": [BRICK["Deionised_Water_Conductivity_Sensor"]], "tags": [ TAG.Point, TAG.Sensor, @@ -1538,7 +1539,8 @@ BRICK.hasQuantity: BRICK.Level, BRICK.hasSubstance: BRICK.Water, "subclasses": { - "Deionised_Water_Level_Sensor": { + "Deionized_Water_Level_Sensor": { + "aliases": [BRICK["Deionised_Water_Level_Sensor"]], "tags": [ TAG.Point, TAG.Sensor, From 6d476160e374aa220ea65769fe22e4be49f63e1b Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 21 Aug 2025 17:46:30 +0200 Subject: [PATCH 04/31] Add new "substance": Solar [no ci] --- bricksrc/definitions.csv | 1 + bricksrc/points.csv | 6 +++--- bricksrc/substances.py | 3 +++ 3 files changed, 7 insertions(+), 3 deletions(-) diff --git a/bricksrc/definitions.csv b/bricksrc/definitions.csv index 5d958526..a8b24afb 100644 --- a/bricksrc/definitions.csv +++ b/bricksrc/definitions.csv @@ -991,6 +991,7 @@ https://brickschema.org/schema/Brick#Shower,"A space containing showers, usually https://brickschema.org/schema/Brick#Site,A geographic region containing 0 or more buildings. Typically used as the encapsulating location for a collection of Brick entities through the hasPart/isPartOf relationships, https://brickschema.org/schema/Brick#Smoke_Alarm,An alarm that indicates the off-normal conditions associated with smoke., https://brickschema.org/schema/Brick#Soil_Temperature_Sensor,Measures the temperature of soil, +https://brickschema.org/schema/Brick#Solar,Relating to the sun, https://brickschema.org/schema/Brick#Solar_Azimuth_Angle_Sensor,Measures the azimuth angle of the sun, https://brickschema.org/schema/Brick#Solar_Irradiance,The power per unit area of solar electromagnetic radiation incident on a surface, https://brickschema.org/schema/Brick#Solar_Irradiance_Sensor,Measures solar irradiance levels for photovoltaic systems, diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 05e1e24c..3da8b402 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -700,9 +700,9 @@ brick:Short_Cycle_Alarm,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a s brick:Smoke_Alarm,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. brick:Smoke_Detection_Alarm,,,,,,brick:Alarm,Smoke Detection, brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil -brick:Solar_Azimuth_Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,Solar Azimuth,Measures the azimuth angle of the sun -brick:Solar_Irradiance_Sensor,,,,,,brick:Sensor,Solar Irradiance,Measures solar irradiance levels for photovoltaic systems -brick:Solar_Zenith_Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,Solar Zenith,Measures the zenith angle of the sun +brick:Solar_Azimuth_Angle_Sensor,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun +brick:Solar_Irradiance_Sensor,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems +brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun brick:Speed_Command,,,,,,brick:Command,Speed,A command to set speed to a certain degree. brick:Speed_Mode_Status,,,,,,brick:Status,Speed Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." brick:Speed_Reset_Command,,,,,,brick:Command,Speed Reset, diff --git a/bricksrc/substances.py b/bricksrc/substances.py index 8e4831ee..1215d4b3 100644 --- a/bricksrc/substances.py +++ b/bricksrc/substances.py @@ -5,6 +5,9 @@ "Light": { "tags": [TAG.Light], }, + "Solar": { + "tags": [TAG.Solar], + }, "Fluid": { SKOS.narrower: { "Refrigerant": {}, From d661851c71bdaff21249594c64a64ba0c689be2f Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 21 Aug 2025 18:01:33 +0200 Subject: [PATCH 05/31] Define all point attributes [no ci] --- bricksrc/points.csv | 30 +++++++++++++++--------------- 1 file changed, 15 insertions(+), 15 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 3da8b402..7c3eec45 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -149,8 +149,8 @@ brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Parameter,Step, brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements -brick:Differential_Speed_Sensor,,,,brick:Differential,,brick:Sensor,Speed, -brick:Differential_Speed_Setpoint,,,,brick:Differential,,brick:Setpoint,Speed,Sets differential speed +brick:Differential_Speed_Sensor,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, +brick:Differential_Speed_Setpoint,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed brick:Differential_Temperature_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements brick:Direction_Command,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon brick:Direction_Sensor,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring @@ -295,7 +295,7 @@ brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:Vel brick:Failure_Alarm,,,,,,brick:Alarm,Failure,"Alarms that indicate the failure of devices, equipment, systems and control loops" brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans brick:Fan_On_Off_Status,,brick:Fan,,,,brick:Status,On Off, -brick:Fan_Speed_Command,,brick:Fan,,,,brick:Command,Speed,Controls the speed of fans +brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans brick:Fault_Reset_Command,,,,,,brick:Command,Fault Reset,Clears a fault status brick:Fault_Status,,,,,,brick:Status,Fault,"Indicates the presence of a fault in a device, system or control loop" @@ -487,7 +487,7 @@ brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,bric brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. brick:Max_Outside_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. brick:Max_Position_Setpoint_Limit,brick:Maximum,,,,,brick:Setpoint_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. -brick:Max_Speed_Setpoint_Limit,brick:Maximum,,,,,brick:Setpoint_Limit,Speed,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Speed_Setpoint_Limit,brick:Maximum,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. brick:Max_Static_Pressure_Setpoint_Limit,brick:Maximum,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. brick:Max_Supply_Air_Temperature_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. @@ -524,7 +524,7 @@ brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,bric brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. brick:Min_Outside_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. brick:Min_Position_Setpoint_Limit,brick:Minimum,,,,,brick:Setpoint_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. -brick:Min_Speed_Setpoint_Limit,brick:Minimum,,,,,brick:Setpoint_Limit,Speed,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Speed_Setpoint_Limit,brick:Minimum,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. brick:Min_Static_Pressure_Setpoint_Limit,brick:Minimum,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. brick:Min_Supply_Air_Temperature_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. @@ -546,7 +546,7 @@ brick:Motion_Sensor,,,,,,brick:Sensor,Motion,Detects the presence of motion in s brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor brick:Motor_Direction_Status,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" brick:Motor_On_Off_Status,,brick:Motor,,,,brick:Status,On Off, -brick:Motor_Speed_Sensor,,brick:Motor,,,,brick:Sensor,Speed, +brick:Motor_Speed_Sensor,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas @@ -554,7 +554,7 @@ brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measure brick:No_Water_Alarm,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system brick:NO2_Level_Sensor,,,,,,brick:Sensor,NO2 Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" -brick:Occupancy_Count_Sensor,,,,,,brick:Sensor,Occupancy Count,Sensors measuring the number of people in an area +brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area brick:Occupancy_Sensor,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area brick:Occupancy_Status,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied brick:Occupied_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Occupied, @@ -659,7 +659,7 @@ brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Tem brick:Radon_Concentration_Sensor,,,,,,brick:Sensor,Radon Concentration,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,,brick:Setpoint,Rated Speed,Sets rated speed +brick:Rated_Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, @@ -703,12 +703,12 @@ brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Senso brick:Solar_Azimuth_Angle_Sensor,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun brick:Solar_Irradiance_Sensor,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun -brick:Speed_Command,,,,,,brick:Command,Speed,A command to set speed to a certain degree. -brick:Speed_Mode_Status,,,,,,brick:Status,Speed Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." -brick:Speed_Reset_Command,,,,,,brick:Command,Speed Reset, -brick:Speed_Sensor,,,,,,brick:Sensor,Speed,Measures the magnitude of velocity of some form of movement -brick:Speed_Setpoint,,,,,,brick:Setpoint,Speed,Sets speed -brick:Speed_Setpoint_Limit,,,,,,brick:Setpoint_Limit,Speed,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. +brick:Speed_Command,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. +brick:Speed_Mode_Status,,,,,quantitykind:Speed,brick:Status,Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Command,Reset, +brick:Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement +brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed +brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. brick:Stage_Enable_Command,,,,,,brick:Command,Stage Enable,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Cooling, @@ -855,7 +855,7 @@ brick:Water_Temperature_Sensor,,,brick:Water,,quantitykind:Temperature,brick:Sen brick:Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water brick:Water_Usage_Sensor,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" brick:Wind_Direction_Sensor,,,,,,brick:Sensor,Wind Direction,Measures the direction of wind in degrees relative to North -brick:Wind_Speed_Sensor,,,,,,brick:Sensor,Wind Speed,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Wind_Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,Wind,"Measured speed of wind, caused by air moving from high to low pressure" brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,,brick:Status,Conditioning Mode,Indicates the mode of AC for a zone brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,,brick:Sensor,Humidity,Measures the relative humidity of zone air From 6f05f5cabf12c2c8f8e662a1f96c39a513596330 Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 28 Aug 2025 16:56:49 +0200 Subject: [PATCH 06/31] Define all point attributes [no ci] --- bricksrc/points.csv | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 7c3eec45..f5aaf852 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -81,7 +81,7 @@ brick:CO2_Differential_Sensor,,,brick:CO2,brick:Differential,,brick:Sensor,,Meas brick:CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air brick:CO2_Sensor,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air brick:CO2_Setpoint,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 -brick:Coldest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Coldest,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Coldest_Zone_Air_Temperature_Sensor,brick:Coldest,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" @@ -621,7 +621,7 @@ brick:Override_Command,,,,,,brick:Command,Override,Controls or reports whether o brick:Ozone_Level_Sensor,,,,,,brick:Sensor,Ozone Level,Measures the concentration of ozone in air brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values brick:Particulate_Matter_Sensor,,,,,,brick:Sensor,Particulate Matter,Detects pollutants in the ambient air -brick:Peak_Demand_Sensor,,,,,,brick:Sensor,Peak Demand,The peak power consumed by a process over some period of time +brick:Peak_Demand_Sensor,brick:Peak,,,,,brick:Sensor,Demand,The peak power consumed by a process over some period of time brick:Photovoltaic_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Photovoltaic Output,Senses the amperes of electrical current produced as output by a photovoltaic device brick:PID_Parameter,,,,,,brick:Parameter,PID, brick:Piezoelectric_Sensor,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" @@ -836,7 +836,7 @@ brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A brick:Voltage_Ratio_Setpoint,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object brick:Warm_Cool_Adjust_Sensor,,,,,,brick:Sensor,Warm Cool Adjust,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" -brick:Warmest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Warmest,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' brick:Waste_Amount_Sensor,,,,,,brick:Sensor,Waste Amount,A metric used for measuring the quantity of waste generated in a building. brick:Water_Alarm,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" brick:Water_Differential_Pressure_Sensor,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. From f48bcfc13efaca57be3a7e58ce556d50afb8df83 Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 28 Aug 2025 18:25:09 +0200 Subject: [PATCH 07/31] Define all point attributes [no ci] --- bricksrc/points.csv | 156 ++++++++++++++++++++++---------------------- 1 file changed, 78 insertions(+), 78 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index f5aaf852..442a629c 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -10,23 +10,23 @@ brick:Air_Enthalpy_Sensor,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measu brick:Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. brick:Air_Flow_Deadband_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow brick:Air_Flow_Demand_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of air flow required for a process -brick:Air_Flow_Loss_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,Loss,An alarm that indicates loss in air flow. +brick:Air_Flow_Loss_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. brick:Air_Flow_Sensor,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air brick:Air_Flow_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow brick:Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. brick:Air_Grains_Sensor,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air brick:Air_Pressure_Sensor,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. brick:Air_Pressure_Setpoint,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, -brick:Air_Quality_Sensor,,,brick:Air,,,brick:Sensor,Quality,A sensor which provides a measure of air quality +brick:Air_Quality_Sensor,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality brick:Air_Static_Pressure_Sensor,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." -brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,quantitykind:StaticPressure,brick:Step_Parameter,, brick:Air_Temperature_Alarm,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. -brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Parameter,Integral Time, +brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air brick:Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air brick:Air_Temperature_Setpoint_Limit,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. -brick:Air_Temperature_Step_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Parameter,Step, -brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,quantitykind:Velocity,brick:Sensor,Pressure,Measures the difference between total air pressure and static air pressure. +brick:Air_Temperature_Step_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action brick:Alarm_Delay_Parameter,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met @@ -55,14 +55,14 @@ brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,quantitykind:VolumeFlowRa brick:Capacity_Sensor,,,,,quantitykind:Capacity,brick:Sensor,, brick:Change_Filter_Alarm,,brick:Filter,,,,brick:Alarm,Change,An alarm that indicates that a filter must be changed brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water -brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,Load Shed, brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, -brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, brick:Chilled_Water_Differential_Pressure_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve brick:Chilled_Water_Differential_Pressure_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water -brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Step, +brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, brick:Chilled_Water_Differential_Temperature_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device brick:Chilled_Water_Flow_Sensor,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit brick:Chilled_Water_Flow_Setpoint,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water @@ -86,8 +86,8 @@ brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick: brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" brick:Command,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. -brick:Communication_Loss_Alarm,,,,,,brick:Alarm,Communication Loss,An alarm that indicates a loss of communication e.g. with a device or controller -brick:Condensate_Leak_Alarm,,,,,,brick:Alarm,Condensate Leak,An alarm that indicates a leak of condensate from a cooling system +brick:Communication_Loss_Alarm,,,,,,brick:Loss_Alarm,Communication,An alarm that indicates a loss of communication e.g. with a device or controller +brick:Condensate_Leak_Alarm,,,,,,brick:Leak_Alarm,Condensate,An alarm that indicates a leak of condensate from a cooling system brick:Condenser_Water_Flow_Sensor,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water brick:Condenser_Water_Flow_Setpoint,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Condenser_Water_Temperature_Sensor,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water @@ -98,15 +98,15 @@ brick:Cooling_Demand_Sensor,,,,,,brick:Sensor,Cooling Demand,Measures the amount brick:Cooling_Demand_Setpoint,,,,,,brick:Setpoint,Cooling Demand,Sets the rate required for cooling brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets discharge air flow for cooling brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of cooling discharge air -brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Cooling Integral Time, -brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Cooling Proportional Band, +brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Cooling, +brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Cooling, brick:Cooling_Enable_Command,,,,,,brick:Command,Cooling Enable,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." brick:Cooling_Mode_Status,,,,,,brick:Status,Cooling Mode,"Indicates whether a system, device or control loop is in a cooling mode" brick:Cooling_Start_Stop_Status,,,,,,brick:Status,Cooling Start Stop, brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets supply air flow rate for cooling brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of supply air for cooling -brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Cooling Integral Time, -brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Cooling Proportional Band, +brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Cooling, +brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Cooling, brick:Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Cooling,Sets temperature for cooling brick:Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Cooling,The cooling setpoint for a specific zone in a building. brick:Core_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. @@ -116,7 +116,7 @@ brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter th brick:Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device brick:Current_Ratio_Setpoint,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor -brick:Curtailment_Override_Command,,,,,,brick:Command,Curtailment Override, +brick:Curtailment_Override_Command,,,,,,brick:Override_Command,Curtailment, brick:Cycle_Alarm,,,,,,brick:Alarm,Cycle,An alarm that indicates off-normal conditions associated with HVAC cycles brick:Damper_Command,,brick:Damper,,,,brick:Command,,Controls properties of dampers brick:Damper_Position_Command,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper @@ -141,13 +141,13 @@ brick:Dewpoint_Setpoint,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Set brick:Differential_Air_Temperature_Setpoint,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure -brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,,,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, brick:Differential_Pressure_Proportional_Band,,,,brick:Differential,quantitykind:Pressure,,Proportional Band, brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. -brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Parameter,Step, +brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements brick:Differential_Speed_Sensor,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, brick:Differential_Speed_Setpoint,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed @@ -175,27 +175,27 @@ brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlow brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,,brick:Sensor,Humidity,Measures the relative humidity of discharge air brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,,brick:Setpoint,Humidity,Humidity setpoint for discharge air brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, -brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Parameter,Proportional Gain, +brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Discharge_Air,,,brick:Alarm,Smoke Detection, brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air -brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Parameter,Integral Time, -brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, brick:Discharge_Air_Static_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system brick:Discharge_Air_Static_Pressure_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air -brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, brick:Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. brick:Discharge_Air_Temperature_Cooling_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Cooling,Sets temperature of discharge air for cooling brick:Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air brick:Discharge_Air_Temperature_Heating_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Heating,Sets temperature of discharge air for heating brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Step, -brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:Velocity,brick:Sensor,Pressure, +brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water,,,brick:Command,System Enable,Enables operation of the domestic hot water system @@ -259,15 +259,15 @@ brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering Medium Temperature Low, brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering Medium Temperature,Measures the temperature of medium-temperature hot water entering a hot water system brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water -brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, -brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, brick:Entering_Water_Flow_Sensor,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system brick:Entering_Water_Flow_Setpoint,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water brick:Entering_Water_Pressure_Sensor,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. brick:Entering_Water_Temperature_Alarm,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. brick:Entering_Water_Temperature_Deadband_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water -brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Parameter,Integral Time, -brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance @@ -276,32 +276,32 @@ brick:Even_Month_Status,,,,,,brick:Status,Even Month, brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit -brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Integral Time, -brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Proportional Band, +brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,,brick:Sensor,Humidity,Measures the relative humidity of exhaust air brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,,brick:Setpoint,Humidity,Humidity setpoint for exhaust air brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow -brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Stack Integral Time, -brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Parameter,Stack Proportional Band, +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, brick:Exhaust_Air_Stack_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack brick:Exhaust_Air_Stack_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate -brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air -brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:Velocity,brick:Sensor,Pressure, -brick:Failure_Alarm,,,,,,brick:Alarm,Failure,"Alarms that indicate the failure of devices, equipment, systems and control loops" +brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Failure_Alarm,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans brick:Fan_On_Off_Status,,brick:Fan,,,,brick:Status,On Off, brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans -brick:Fault_Reset_Command,,,,,,brick:Command,Fault Reset,Clears a fault status -brick:Fault_Status,,,,,,brick:Status,Fault,"Indicates the presence of a fault in a device, system or control loop" +brick:Fault_Reset_Command,,,,,,brick:Reset_Command,Fault,Clears a fault status +brick:Fault_Status,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter -brick:Filter_Reset_Command,,brick:Filter,,,,brick:Command,Reset, +brick:Filter_Reset_Command,,brick:Filter,,,,brick:Reset_Command,, brick:Filter_Status,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. brick:Fire_Sensor,,,,,,brick:Sensor,Fire,Measures the presence of fire @@ -328,15 +328,15 @@ brick:Heating_Demand_Sensor,,,,,,brick:Sensor,Heating Demand,Measures the amount brick:Heating_Demand_Setpoint,,,,,,brick:Setpoint,Heating Demand,Sets the rate required for heating brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets discharge air flow for heating brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of heating discharge air -brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Heating Integral Time, -brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Parameter,Heating Proportional Band, +brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Heating, +brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Heating, brick:Heating_Enable_Command,,,,,,brick:Command,Heating Enable,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." brick:Heating_Mode_Status,,,,,,brick:Status,Heating Mode,"Indicates whether a system, device or control loop is in a heating mode" brick:Heating_Start_Stop_Status,,,,,,brick:Status,Heating Start Stop, brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets supply air flow rate for heating brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of supply air for heating -brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Heating Integral Time, -brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Heating Proportional Band, +brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Heating, +brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Heating, brick:Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Heating,Sets temperature for heating brick:Heating_Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Heating Thermal, brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Heating,The heating setpoint for a specific zone in a building. @@ -354,10 +354,10 @@ brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,High,An al brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Parameter,High,A parameter determining the temperature level at which to trigger a high temperature alarm brick:Hold_Status,,,,,,brick:Status,Hold, brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water -brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, +brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, -brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, brick:Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve brick:Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water brick:Hot_Water_Differential_Temperature_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device @@ -369,14 +369,14 @@ brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water,,,brick:Command,System E brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" brick:Humidification_Start_Stop_Status,,,,,,brick:Status,Humidification Start Stop, -brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Status,Fault,Indicates the presence of a fault in a humidifier +brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier brick:Humidify_Command,,,,,,brick:Command,Humidify, brick:Humidity_Alarm,,,,,,brick:Alarm,Humidity,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. brick:Humidity_Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,Humidity,Sets the size of a deadband of humidity brick:Humidity_Parameter,,,,,,brick:Parameter,Humidity,Parameters relevant to humidity-related systems and points brick:Humidity_Sensor,,,,,,brick:Sensor,Humidity,Measures the concentration of water vapor in air brick:Humidity_Setpoint,,,,,,brick:Setpoint,Humidity,Sets humidity -brick:Humidity_Tolerance_Parameter,,,,,,brick:Parameter,Humidity Tolerance,A parameter determining the difference between upper and lower limits of humidity. +brick:Humidity_Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,Humidity,A parameter determining the difference between upper and lower limits of humidity. brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Tank,brick:Ice,,quantitykind:Temperature,brick:Sensor,Leaving Water,Measures the temperature of water leaving an ice tank brick:Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" brick:Illuminance_Setpoint,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. @@ -385,12 +385,12 @@ brick:Inside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick: brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. brick:Intake_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Intake,Measures air at the interface between the building and the outside brick:Integral_Gain_Parameter,,,,,,brick:Parameter,Integral Gain, -brick:Integral_Time_Parameter,,,,,,brick:Parameter,Integral Time, +brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, brick:Last_Fault_Code_Status,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled brick:Lead_On_Off_Command,,,,,,brick:Command,Lead On Off,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" -brick:Leak_Alarm,,,,,,brick:Alarm,Leak,An alarm that indicates leaks occured in systems containing fluids +brick:Leak_Alarm,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water brick:Leaving_Chilled_Water_Temperature_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller @@ -414,15 +414,15 @@ brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick: brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving Medium Temperature Low, brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving Medium Temperature,Measures the temperature of medium-temperature hot water supplied by a hot water system brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water -brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Integral Time, -brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Parameter,Proportional Band, +brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, brick:Leaving_Water_Flow_Sensor,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system brick:Leaving_Water_Flow_Setpoint,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water brick:Leaving_Water_Pressure_Sensor,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. brick:Leaving_Water_Temperature_Alarm,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. brick:Leaving_Water_Temperature_Deadband_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water -brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Parameter,Integral Time, -brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system brick:Leaving_Water_Temperature_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water brick:Level_Command,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. @@ -617,7 +617,7 @@ brick:Overload_Alarm,,,,,,brick:Alarm,Overload,An alarm that can indicate when a brick:Overridden_Off_Status,,,,,,brick:Status,Overridden Off,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" brick:Overridden_On_Status,,,,,,brick:Status,Overridden On,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden -brick:Override_Command,,,,,,brick:Command,Override,Controls or reports whether or not a device or control loop is in 'override' +brick:Override_Command,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' brick:Ozone_Level_Sensor,,,,,,brick:Sensor,Ozone Level,Measures the concentration of ozone in air brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values brick:Particulate_Matter_Sensor,,,,,,brick:Sensor,Particulate Matter,Detects pollutants in the ambient air @@ -637,7 +637,7 @@ brick:Position_Limit,,,,,,brick:Limit,Position,A parameter that places a lower o brick:Position_Sensor,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion brick:Power_Alarm,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. brick:Power_Factor_Sensor,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." -brick:Power_Loss_Alarm,,,,,quantitykind:Power,brick:Alarm,Loss,An alarm that indicates a power failure. +brick:Power_Loss_Alarm,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. brick:Power_Sensor,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed brick:Pre_Filter_Status,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced brick:Preheat_Command,,,,,,brick:Command,Preheat,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer @@ -648,8 +648,8 @@ brick:Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indica brick:Pressure_Sensor,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area brick:Pressure_Setpoint,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure brick:Pressure_Status,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds -brick:Proportional_Band_Parameter,,,,,,brick:Parameter,Proportional Band, -brick:Proportional_Gain_Parameter,,,,,,brick:Parameter,Proportional Gain, +brick:Proportional_Band_Parameter,,,,,,brick:Proportional_Band_Parameter,, +brick:Proportional_Gain_Parameter,,,,,,brick:Proportional_Gain_Parameter,, brick:Pump_Command,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) brick:Pump_On_Off_Status,,brick:Pump,,,,brick:Status,On Off, brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump @@ -667,7 +667,7 @@ brick:Reheat_Command,,,,,,brick:Command,Reheat,"A command to activate reheating, brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay brick:Remotely_On_Off_Status,,,,,,brick:Status,Remotely On Off, -brick:Reset_Command,,,,,,brick:Command,Reset,"Commands that reset a flag, property or value to its default" +brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air brick:Return_Air_CO2_Sensor,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air @@ -694,7 +694,7 @@ brick:Run_Time_Sensor,,,,,,brick:Sensor,Run Time,"Measures the duration for whic brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). -brick:Sensor_Failure_Alarm,,,,,,brick:Alarm,Sensor Failure, +brick:Sensor_Failure_Alarm,,,,,,brick:Failure_Alarm,Sensor, brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set brick:Short_Cycle_Alarm,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle brick:Smoke_Alarm,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. @@ -705,7 +705,7 @@ brick:Solar_Irradiance_Sensor,,,brick:Solar,,quantitykind:Irradiance,brick:Senso brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun brick:Speed_Command,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. brick:Speed_Mode_Status,,,,,quantitykind:Speed,brick:Status,Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." -brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Command,Reset, +brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Reset_Command,, brick:Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. @@ -720,16 +720,16 @@ brick:Standby_Unit_On_Off_Status,,,,,,brick:Status,Standby Unit On Off,Indicates brick:Start_Stop_Command,,,,,,brick:Command,Start Stop,A Start/Stop Command controls or reports the active/inactive status of a control sequence brick:Start_Stop_Status,,,,,,brick:Status,Start Stop,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure -brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Parameter,Integral Time, -brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, brick:Static_Pressure_Sensor,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work brick:Static_Pressure_Setpoint,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure brick:Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, brick:Status,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" brick:Steam_On_Off_Command,,,brick:Steam,,,brick:Command,On Off, brick:Steam_Usage_Sensor,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" -brick:Step_Parameter,,,,,,brick:Parameter,Step, +brick:Step_Parameter,,,,,,brick:Step_Parameter,, brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit @@ -743,27 +743,27 @@ brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,b brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,,brick:Sensor,Humidity,Measures the relative humidity of supply air brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,,brick:Setpoint,Humidity,Humidity setpoint for supply air brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, -brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Parameter,Proportional Gain, +brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Supply_Air,,,brick:Alarm,Smoke Detection, brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air -brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Parameter,Integral Time, -brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Parameter,Proportional Band, +brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, brick:Supply_Air_Static_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system brick:Supply_Air_Static_Pressure_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air -brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Parameter,Step, +brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, brick:Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. brick:Supply_Air_Temperature_Cooling_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Cooling, brick:Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air brick:Supply_Air_Temperature_Heating_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Heating, brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Proportional Band, +brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Parameter,Step, -brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:Velocity,brick:Sensor,Pressure, +brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Switch_Status,,brick:Switch,,,,brick:Status,,Status of a switch brick:System_Enable_Command,,,,,,brick:Command,System Enable,Enables operation of a system brick:System_Shutdown_Status,,,,,,brick:Status,System Shutdown,Indicates if a system has been shutdown @@ -779,8 +779,8 @@ brick:Temperature_Low_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Reset_Se brick:Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points brick:Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature -brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Step, -brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Tolerance,A parameter determining the difference between upper and lower limits of temperature. +brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. brick:Temporary_Occupancy_Status,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" brick:Thermal_Energy_Usage_Sensor,,,,,,brick:Sensor,Thermal Energy Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, @@ -789,14 +789,14 @@ brick:Time_Parameter,,,,,,brick:Parameter,Time, brick:Time_Setpoint,,,,,,brick:Setpoint,Time, brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." -brick:Tolerance_Parameter,,,,,,brick:Parameter,Tolerance,difference between upper and lower limits of size for a given nominal dimension or value. +brick:Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. brick:Torque_Sensor,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" brick:TVOC_Level_Sensor,,,,,,brick:Sensor,TVOC Level,A sensor measuring the level of all VOCs in air brick:TVOC_Sensor,,,,,,brick:Sensor,TVOC, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air -brick:Unit_Failure_Alarm,,,,,,brick:Alarm,Unit Failure,An alarm that indicates the failure of an equipment or device +brick:Unit_Failure_Alarm,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Cooling,Sets discharge air flow for cooling when unoccupied brick:Unoccupied_Cooling_Mode_Status,,,,,,brick:Status,Unoccupied Cooling Mode,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" @@ -826,8 +826,8 @@ brick:Valve_Position_Alarm,,brick:Valve,,,,brick:Alarm,Position,An alarm that in brick:Valve_Position_Command,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve brick:Valve_Position_Sensor,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open brick:Valve_Status,,brick:Valve,,,,brick:Status,,The current status of the valve. -brick:Velocity_Pressure_Sensor,,,,,quantitykind:Velocity,brick:Sensor,Pressure,Measures the difference between total pressure and static pressure -brick:Velocity_Pressure_Setpoint,,,,,quantitykind:Velocity,brick:Setpoint,Pressure,Sets static veloicty pressure +brick:Velocity_Pressure_Sensor,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure +brick:Velocity_Pressure_Setpoint,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure brick:Vent_Operating_Mode_Status,,,,,,brick:Status,Vent Operating Mode,Indicates the current operating mode of a vent brick:Ventilation_Air_Flow_Ratio_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. brick:VFD_Enable_Command,,brick:VFD,,,,brick:Command,Enable,Enables operation of a variable frequency drive @@ -847,7 +847,7 @@ brick:Water_Flow_Sensor,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor, brick:Water_Flow_Setpoint,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water brick:Water_Level_Alarm,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin brick:Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container -brick:Water_Loss_Alarm,,,brick:Water,,,brick:Alarm,Loss,An alarm that indicates a loss of water e.g. during transport +brick:Water_Loss_Alarm,,,brick:Water,,,brick:Loss_Alarm,,An alarm that indicates a loss of water e.g. during transport brick:Water_Pressure_Sensor,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. brick:Water_Pressure_Setpoint,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, brick:Water_Temperature_Alarm,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. From ba902a38ddf7295d14028f61a0d44b26b9b62179 Mon Sep 17 00:00:00 2001 From: ektrah Date: Mon, 1 Sep 2025 19:35:22 +0200 Subject: [PATCH 08/31] Define all point attributes [no ci] --- bricksrc/points.csv | 106 ++++++++++++++++++++++---------------------- 1 file changed, 53 insertions(+), 53 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 442a629c..7c27478c 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,4 +1,4 @@ -@id,brick:isAggregated,brick:ofEquipment,brick:hasSubstance,brick:isDifferential,brick:hasQuantity,rdfs:subClassOf,todo:,skos:definition +@id,brick:isAggregated,brick:ofEquipment,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/brick:hasEnumeration,rdfs:subClassOf,todo:,skos:definition brick:Absolute_Humidity_Sensor,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity brick:Acceleration_Time_Setpoint,,,,,,brick:Setpoint,Acceleration Time, brick:Active_Power_Sensor,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" @@ -33,8 +33,8 @@ brick:Alarm_Delay_Parameter,,,,,,brick:Parameter,Alarm Delay,A parameter determi brick:Alarm_Sensitivity_Parameter,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. brick:Ammonia_Sensor,,,brick:Ammonia,,,brick:Sensor,,Measures the concentration of ammonia in air brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon -brick:Automatic_Mode_Command,,,,,,brick:Command,Automatic Mode,"Controls whether or not a device or controller is operating in ""Automatic"" mode" -brick:Availability_Status,,,,,,brick:Status,Availability,"Indicates if a piece of equipment, system, or functionality is available for operation" +brick:Automatic_Mode_Command,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" +brick:Availability_Status,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" brick:Average_Cooling_Demand_Sensor,brick:Average,,,,,brick:Sensor,Cooling Demand,Measures the average power consumed by a cooling process as the amount of power consumed over some interval brick:Average_Discharge_Air_Flow_Sensor,brick:Average,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of discharge air over some interval brick:Average_Exhaust_Air_Static_Pressure_Sensor,brick:Average,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time @@ -44,16 +44,16 @@ brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,brick:Zone_Air,,quantit brick:Battery_Voltage_Sensor,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery brick:Boiler_Command,,brick:Boiler,,,,brick:Command,,A command to control a boiler brick:Box_Mode_Command,,,,,,brick:Command,Box Mode, -brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,,brick:Setpoint,Humidity,Setpoint for humidity in a building +brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building brick:Building_Air_Static_Pressure_Sensor,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building brick:Building_Air_Static_Pressure_Setpoint,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building brick:Bypass_Air_Flow_Sensor,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air -brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,,brick:Setpoint,Humidity,Humidity setpoint for bypass air +brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air brick:Bypass_Command,,,,,,brick:Command,Bypass, brick:Bypass_Water_Flow_Sensor,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water brick:Capacity_Sensor,,,,,quantitykind:Capacity,brick:Sensor,, -brick:Change_Filter_Alarm,,brick:Filter,,,,brick:Alarm,Change,An alarm that indicates that a filter must be changed +brick:Change_Filter_Alarm,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, @@ -102,7 +102,7 @@ brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharg brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Cooling, brick:Cooling_Enable_Command,,,,,,brick:Command,Cooling Enable,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." brick:Cooling_Mode_Status,,,,,,brick:Status,Cooling Mode,"Indicates whether a system, device or control loop is in a cooling mode" -brick:Cooling_Start_Stop_Status,,,,,,brick:Status,Cooling Start Stop, +brick:Cooling_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Cooling, brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets supply air flow rate for cooling brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of supply air for cooling brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Cooling, @@ -126,7 +126,7 @@ brick:Damper_Position_Status,,brick:Damper,,,,brick:Status,Position, brick:DC_Bus_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,DC Bus,Measures the voltage across a DC bus brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband brick:Deceleration_Time_Setpoint,,,,,,brick:Setpoint,Deceleration Time, -brick:Dehumidification_Start_Stop_Status,,,,,,brick:Status,Dehumidification Start Stop, +brick:Dehumidification_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. brick:Deionized_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water @@ -172,8 +172,8 @@ brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind: brick:Discharge_Air_Flow_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies brick:Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow -brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,,brick:Sensor,Humidity,Measures the relative humidity of discharge air -brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,,brick:Setpoint,Humidity,Humidity setpoint for discharge air +brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air +brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Discharge_Air,,,brick:Alarm,Smoke Detection, @@ -204,7 +204,7 @@ brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quanti brick:Drive_Ready_Status,,,,,,brick:Status,Drive Ready,"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" brick:Duct_Air_Static_Pressure_Setpoint,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,,brick:Status,EconCycle Start Stop, +brick:EconCycle_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,EconCycle, brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Effective, brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Cooling,The effective cooling setpoint for a specific zone in a building. brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Effective, @@ -280,8 +280,8 @@ brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate -brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,,brick:Sensor,Humidity,Measures the relative humidity of exhaust air -brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,,brick:Setpoint,Humidity,Humidity setpoint for exhaust air +brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air +brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, @@ -294,7 +294,7 @@ brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,quantitykind:Temperatu brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Failure_Alarm,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans -brick:Fan_On_Off_Status,,brick:Fan,,,,brick:Status,On Off, +brick:Fan_On_Off_Status,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans brick:Fault_Reset_Command,,,,,,brick:Reset_Command,Fault,Clears a fault status @@ -332,7 +332,7 @@ brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharg brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Heating, brick:Heating_Enable_Command,,,,,,brick:Command,Heating Enable,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." brick:Heating_Mode_Status,,,,,,brick:Status,Heating Mode,"Indicates whether a system, device or control loop is in a heating mode" -brick:Heating_Start_Stop_Status,,,,,,brick:Status,Heating Start Stop, +brick:Heating_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Heating, brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets supply air flow rate for heating brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of supply air for heating brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Heating, @@ -344,8 +344,8 @@ brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,H brick:High_CO2_Alarm,,,brick:CO2,,,brick:Alarm,High,A device that indicates high concentration of carbon dioxide. brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates that discharge air temperature is too high brick:High_Head_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,High Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. -brick:High_Humidity_Alarm,,,,,,brick:Alarm,High Humidity,An alarm that indicates high concentration of water vapor in the air. -brick:High_Humidity_Alarm_Parameter,,,,,,brick:Alarm_Parameter,High Humidity,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,High,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,High,A parameter determining the humidity level at which to trigger a high humidity alarm brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,High Lockout,The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates that return air temperature is too high brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,High Cutout,A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. @@ -368,15 +368,15 @@ brick:Hot_Water_Static_Pressure_Setpoint,,,brick:Hot_Water,,quantitykind:StaticP brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water,,,brick:Command,System Enable,Enables operation of the hot water system brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" -brick:Humidification_Start_Stop_Status,,,,,,brick:Status,Humidification Start Stop, +brick:Humidification_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Humidification, brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier brick:Humidify_Command,,,,,,brick:Command,Humidify, -brick:Humidity_Alarm,,,,,,brick:Alarm,Humidity,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. -brick:Humidity_Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,Humidity,Sets the size of a deadband of humidity -brick:Humidity_Parameter,,,,,,brick:Parameter,Humidity,Parameters relevant to humidity-related systems and points -brick:Humidity_Sensor,,,,,,brick:Sensor,Humidity,Measures the concentration of water vapor in air -brick:Humidity_Setpoint,,,,,,brick:Setpoint,Humidity,Sets humidity -brick:Humidity_Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,Humidity,A parameter determining the difference between upper and lower limits of humidity. +brick:Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. +brick:Humidity_Deadband_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity +brick:Humidity_Parameter,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points +brick:Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air +brick:Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity +brick:Humidity_Tolerance_Parameter,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Tank,brick:Ice,,quantitykind:Temperature,brick:Sensor,Leaving Water,Measures the temperature of water leaving an ice tank brick:Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" brick:Illuminance_Setpoint,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. @@ -389,7 +389,7 @@ brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, brick:Last_Fault_Code_Status,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled -brick:Lead_On_Off_Command,,,,,,brick:Command,Lead On Off,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" +brick:Lead_On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" brick:Leak_Alarm,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water @@ -439,7 +439,7 @@ brick:Load_Shed_Command,,,,,,brick:Command,Load Shed,Controls load shedding beha brick:Load_Shed_Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,Load Shed, brick:Load_Shed_Setpoint,,,,,,brick:Setpoint,Load Shed, brick:Load_Shed_Status,,,,,,brick:Status,Load Shed,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,,brick:Status,Locally On Off, +brick:Locally_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Locally, brick:Lockout_Status,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" brick:Lockout_Temperature_Differential_Parameter,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low,An alarm that indicates that the air flow is lower than normal. @@ -447,8 +447,8 @@ brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Alarm,Low,An alarm that indicate brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low,An alarm that indicates that the discharge air flow is lower than normal. brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,Low, brick:Low_Freeze_Protect_Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Low Freeze Protect, -brick:Low_Humidity_Alarm,,,,,,brick:Alarm,Low Humidity,An alarm that indicates low concentration of water vapor in the air. -brick:Low_Humidity_Alarm_Parameter,,,,,,brick:Alarm_Parameter,Low Humidity,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,Low,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,Low,A parameter determining the humidity level at which to trigger a low humidity alarm brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Low Lockout,The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Low Enable, brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Low Enable, @@ -536,8 +536,8 @@ brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick brick:Min_Water_Level_Alarm,brick:Minimum,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the minimum water level was reached brick:Min_Water_Temperature_Setpoint,brick:Minimum,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for min water temperature brick:Mixed_Air_Flow_Sensor,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air -brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,,brick:Sensor,Humidity,Measures the humidity of mixed air -brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,,brick:Setpoint,Humidity,Humidity setpoint for mixed air +brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air +brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air brick:Mixed_Air_Temperature_Sensor,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air brick:Mixed_Air_Temperature_Setpoint,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air brick:Mode_Command,,,,,,brick:Command,Mode,Controls the operating mode of a device or controller @@ -545,7 +545,7 @@ brick:Mode_Status,,,,,,brick:Status,Mode,"Indicates which mode a system, device brick:Motion_Sensor,,,,,,brick:Sensor,Motion,Detects the presence of motion in some area brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor brick:Motor_Direction_Status,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" -brick:Motor_On_Off_Status,,brick:Motor,,,,brick:Status,On Off, +brick:Motor_On_Off_Status,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Motor_Speed_Sensor,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas @@ -572,7 +572,7 @@ brick:Occupied_Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind brick:Occupied_Heating_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Occupied Heating,Sets the size of a deadband of temperature for heating when occupied brick:Occupied_Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Occupied Heating,Sets temperature for heating when occupied brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Heating,Sets temperature for zone air heating when occupied -brick:Occupied_Humidity_Setpoint,,,,,,brick:Setpoint,Occupied Humidity,Target humidity level when the location is occupied. +brick:Occupied_Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,Occupied,Target humidity level when the location is occupied. brick:Occupied_Load_Shed_Command,,,,,,brick:Command,Occupied Load Shed, brick:Occupied_Mode_Status,,,,,,brick:Status,Occupied Mode,"Indicates if a system, device or control loop is in ""Occupied"" mode" brick:Occupied_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, @@ -583,12 +583,12 @@ brick:Occupied_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantityki brick:Off_Command,,,,,,brick:Command,Off,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" brick:Off_Status,,,,,,brick:Status,Off,"Indicates if a control loop, relay or equipment is off" brick:On_Command,,,,,,brick:Command,On,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" -brick:On_Off_Command,,,,,,brick:Command,On Off,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" -brick:On_Off_Status,,,,,,brick:Status,On Off,"Indicates the on/off status of a control loop, relay or equipment" +brick:On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" +brick:On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" brick:On_Status,,,,,,brick:Status,On,"Indicates if a control loop, relay or equipment is on" brick:On_Timer_Sensor,,,,,,brick:Sensor,On Timer,"Measures the duration for which a device was in an active or ""on"" state" -brick:Open_Close_Command,,,,,,brick:Command,Open Close,"A binary signal given to a device, such as a damper or valve, to either open or close" -brick:Open_Close_Status,,,,,,brick:Status,Open Close,Indicates the open/close status of a device such as a damper or valve +brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" +brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, brick:Operating_Mode_Status,,,,,,brick:Status,Operating Mode,"Indicates the current operating mode of a system, device or control loop" brick:Output_Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,Output, @@ -600,8 +600,8 @@ brick:Outside_Air_Enthalpy_Sensor,,,brick:Outside_Air,,quantitykind:Enthalpy,bri brick:Outside_Air_Flow_Sensor,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air -brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,,brick:Sensor,Humidity,Measures the relative humidity of outside air -brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,,brick:Setpoint,Humidity,Humidity setpoint for outside air +brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air +brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, @@ -651,7 +651,7 @@ brick:Pressure_Status,,,,,quantitykind:Pressure,brick:Status,,Indicates if press brick:Proportional_Band_Parameter,,,,,,brick:Proportional_Band_Parameter,, brick:Proportional_Gain_Parameter,,,,,,brick:Proportional_Gain_Parameter,, brick:Pump_Command,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) -brick:Pump_On_Off_Status,,brick:Pump,,,,brick:Status,On Off, +brick:Pump_On_Off_Status,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump brick:PV_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,PV Output,See Photovoltaic_Current_Output_Sensor brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. @@ -666,7 +666,7 @@ brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, brick:Reheat_Command,,,,,,brick:Command,Reheat,"A command to activate reheating, which is used for either heating or for dehumidification purposes" brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,,brick:Status,Remotely On Off, +brick:Remotely_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Remotely, brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air @@ -678,8 +678,8 @@ brick:Return_Air_Differential_Pressure_Setpoint,,,brick:Return_Air,brick:Differe brick:Return_Air_Enthalpy_Sensor,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air brick:Return_Air_Flow_Sensor,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air brick:Return_Air_Grains_Sensor,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air -brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,,brick:Sensor,Humidity,Measures the relative humidity of return air -brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,,brick:Setpoint,Humidity,Humidity setpoint for return air +brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air +brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air brick:Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. brick:Return_Air_Temperature_High_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, brick:Return_Air_Temperature_Low_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, @@ -712,13 +712,13 @@ brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parame brick:Stage_Enable_Command,,,,,,brick:Command,Stage Enable,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Cooling, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,,brick:Status,Standby Glycool Unit On Off,Indicates the on/off status of a standby glycool unit +brick:Standby_Glycool_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Glycool Unit,Indicates the on/off status of a standby glycool unit brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Heating, brick:Standby_Load_Shed_Command,,,,,,brick:Command,Standby Load Shed, brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, -brick:Standby_Unit_On_Off_Status,,,,,,brick:Status,Standby Unit On Off,Indicates the on/off status of a standby unit -brick:Start_Stop_Command,,,,,,brick:Command,Start Stop,A Start/Stop Command controls or reports the active/inactive status of a control sequence -brick:Start_Stop_Status,,,,,,brick:Status,Start Stop,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) +brick:Standby_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Unit,Indicates the on/off status of a standby unit +brick:Start_Stop_Command,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence +brick:Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, @@ -727,7 +727,7 @@ brick:Static_Pressure_Setpoint,,,,,quantitykind:StaticPressure,brick:Setpoint,,S brick:Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, brick:Status,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" -brick:Steam_On_Off_Command,,,brick:Steam,,,brick:Command,On Off, +brick:Steam_On_Off_Command,,,brick:Steam,,brick:EnumerationKind-On_Off,brick:Command,, brick:Steam_Usage_Sensor,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" brick:Step_Parameter,,,,,,brick:Step_Parameter,, brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, @@ -740,8 +740,8 @@ brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Volume brick:Supply_Air_Flow_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, brick:Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate -brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,,brick:Sensor,Humidity,Measures the relative humidity of supply air -brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,,brick:Setpoint,Humidity,Humidity setpoint for supply air +brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air +brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Supply_Air,,,brick:Alarm,Smoke Detection, @@ -782,7 +782,7 @@ brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets tem brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Step_Parameter,, brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. brick:Temporary_Occupancy_Status,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" -brick:Thermal_Energy_Usage_Sensor,,,,,,brick:Sensor,Thermal Energy Usage,A sensor that records the quantity of thermal energy consumed in a given period +brick:Thermal_Energy_Usage_Sensor,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat brick:Time_Parameter,,,,,,brick:Parameter,Time, @@ -812,7 +812,7 @@ brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantityki brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Unoccupied Heating, brick:Unoccupied_Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Unoccupied Heating, brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Heating,Sets temperature of air when unoccupied for heating within a specific zone -brick:Unoccupied_Humidity_Setpoint,,,,,,brick:Setpoint,Unoccupied Humidity,Target humidity level when the location is unoccupied. +brick:Unoccupied_Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,Unoccupied,Target humidity level when the location is unoccupied. brick:Unoccupied_Load_Shed_Command,,,,,,brick:Command,Unoccupied Load Shed, brick:Unoccupied_Mode_Status,,,,,,brick:Status,Unoccupied Mode, brick:Unoccupied_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, @@ -858,8 +858,8 @@ brick:Wind_Direction_Sensor,,,,,,brick:Sensor,Wind Direction,Measures the direct brick:Wind_Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,Wind,"Measured speed of wind, caused by air moving from high to low pressure" brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,,brick:Status,Conditioning Mode,Indicates the mode of AC for a zone brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air -brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,,brick:Sensor,Humidity,Measures the relative humidity of zone air -brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,,brick:Setpoint,Humidity,Humidity setpoint for zone air +brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air +brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone brick:Zone_CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone brick:Zone_Occupied_Load_Shed_Command,,,,,,brick:Command,Zone Occupied Load Shed, From 30785968da8bf659fab5e057433061f3a5173299 Mon Sep 17 00:00:00 2001 From: ektrah Date: Mon, 1 Sep 2025 19:47:01 +0200 Subject: [PATCH 09/31] Fix Differential_Pressure_Proportional_Band_Parameter [no ci] --- bricksrc/definitions.csv | 2 +- bricksrc/parameter.py | 7 ++++++- bricksrc/points.csv | 2 +- 3 files changed, 8 insertions(+), 3 deletions(-) diff --git a/bricksrc/definitions.csv b/bricksrc/definitions.csv index a8b24afb..931fabba 100644 --- a/bricksrc/definitions.csv +++ b/bricksrc/definitions.csv @@ -259,7 +259,7 @@ https://brickschema.org/schema/Brick#Differential_Pressure_Bypass_Valve,"A 2-way https://brickschema.org/schema/Brick#Differential_Pressure_Deadband_Setpoint,Sets the size of a deadband of differential pressure, https://brickschema.org/schema/Brick#Differential_Pressure_Integral_Time_Parameter,, https://brickschema.org/schema/Brick#Differential_Pressure_Load_Shed_Status,, -https://brickschema.org/schema/Brick#Differential_Pressure_Proportional_Band,, +https://brickschema.org/schema/Brick#Differential_Pressure_Proportional_Band_Parameter,, https://brickschema.org/schema/Brick#Differential_Pressure_Sensor,Measures the difference between two applied pressures, https://brickschema.org/schema/Brick#Differential_Pressure_Setpoint,Sets differential pressure, https://brickschema.org/schema/Brick#Differential_Pressure_Step_Parameter,, diff --git a/bricksrc/parameter.py b/bricksrc/parameter.py index 62497ed2..19f2f1c2 100644 --- a/bricksrc/parameter.py +++ b/bricksrc/parameter.py @@ -577,7 +577,12 @@ TAG.PID, ], "subclasses": { - "Differential_Pressure_Proportional_Band": { + "Differential_Pressure_Proportional_Band_Parameter": { + "aliases": [ + BRICK[ + "Differential_Pressure_Proportional_Band" + ] + ], "tags": [ TAG.Point, TAG.Differential, diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 7c27478c..3f933c0e 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -143,7 +143,7 @@ brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,brick:Leaving_Wat brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,,,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, -brick:Differential_Pressure_Proportional_Band,,,,brick:Differential,quantitykind:Pressure,,Proportional Band, +brick:Differential_Pressure_Proportional_Band_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. From d903338980d1360aa8d4a1f9359afb70beefe17e Mon Sep 17 00:00:00 2001 From: ektrah Date: Tue, 2 Sep 2025 10:21:18 +0200 Subject: [PATCH 10/31] Add additional substances [no ci] --- bricksrc/definitions.csv | 1 - bricksrc/points.csv | 30 +++++++++++++++--------------- bricksrc/substances.py | 21 +++++++++++++++++---- 3 files changed, 32 insertions(+), 20 deletions(-) diff --git a/bricksrc/definitions.csv b/bricksrc/definitions.csv index 931fabba..63194abc 100644 --- a/bricksrc/definitions.csv +++ b/bricksrc/definitions.csv @@ -41,7 +41,6 @@ https://brickschema.org/schema/Brick#Alarm,Alarm points are signals (either audi https://brickschema.org/schema/Brick#Alarm_Delay_Parameter,A parameter determining how long to delay an alarm after sufficient conditions have been met, https://brickschema.org/schema/Brick#Alarm_Sensitivity_Parameter,A parameter indicates the sensitivity to activate an alarm., https://brickschema.org/schema/Brick#Alternating_Current_Frequency,The frequency of the oscillations of alternating current, -https://brickschema.org/schema/Brick#Ammonia,A colorless gas with a distinctive pungent smell, https://brickschema.org/schema/Brick#Ammonia_Sensor,Measures the concentration of ammonia in air, https://brickschema.org/schema/Brick#Angle_Sensor,Measues the planar angle of some phenomenon, https://brickschema.org/schema/Brick#Atrium,a large open-air or skylight covered space surrounded by a building.,https://en.wikipedia.org/wiki/Atrium_(architecture) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 3f933c0e..44749260 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -31,7 +31,7 @@ brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperatu brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action brick:Alarm_Delay_Parameter,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met brick:Alarm_Sensitivity_Parameter,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. -brick:Ammonia_Sensor,,,brick:Ammonia,,,brick:Sensor,,Measures the concentration of ammonia in air +brick:Ammonia_Sensor,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon brick:Automatic_Mode_Command,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" brick:Availability_Status,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" @@ -307,7 +307,7 @@ brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,brick: brick:Fire_Sensor,,,,,,brick:Sensor,Fire,Measures the presence of fire brick:Flow_Sensor,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow -brick:Formaldehyde_Level_Sensor,,,,,,brick:Sensor,Formaldehyde Level,Measures the concentration of formaldehyde in air +brick:Formaldehyde_Level_Sensor,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air brick:Freeze_Status,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen brick:Frequency_Command,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" @@ -503,7 +503,7 @@ brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,br brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Status,Medium Pressure Load Shed, brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Medium Pressure,Measures the difference in water pressure between sections of a medium temperature hot water system brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,Medium Pressure, -brick:Methane_Level_Sensor,,,,,,brick:Sensor,Methane Level,Measures the concentration of methane in air +brick:Methane_Level_Sensor,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air brick:Min_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. brick:Min_Air_Temperature_Setpoint,brick:Minimum,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for minimum air temperature brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. @@ -552,7 +552,7 @@ brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,b brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" brick:No_Water_Alarm,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system -brick:NO2_Level_Sensor,,,,,,brick:Sensor,NO2 Level,Measures the concentration of NO2 in air +brick:NO2_Level_Sensor,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area brick:Occupancy_Sensor,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area @@ -618,20 +618,20 @@ brick:Overridden_Off_Status,,,,,,brick:Status,Overridden Off,"Indicates if a con brick:Overridden_On_Status,,,,,,brick:Status,Overridden On,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden brick:Override_Command,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' -brick:Ozone_Level_Sensor,,,,,,brick:Sensor,Ozone Level,Measures the concentration of ozone in air +brick:Ozone_Level_Sensor,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values -brick:Particulate_Matter_Sensor,,,,,,brick:Sensor,Particulate Matter,Detects pollutants in the ambient air +brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air brick:Peak_Demand_Sensor,brick:Peak,,,,,brick:Sensor,Demand,The peak power consumed by a process over some period of time brick:Photovoltaic_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Photovoltaic Output,Senses the amperes of electrical current produced as output by a photovoltaic device brick:PID_Parameter,,,,,,brick:Parameter,PID, brick:Piezoelectric_Sensor,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" brick:PIR_Sensor,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors -brick:PM1_Level_Sensor,,,,,,brick:Sensor,PM1 Level,Detects level of particulates of size 1 microns -brick:PM1_Sensor,,,,,,brick:Sensor,PM1,Detects matter of size 1 micron -brick:PM10_Level_Sensor,,,,,,brick:Sensor,PM10 Level,Detects level of particulates of size 10 microns -brick:PM10_Sensor,,,,,,brick:Sensor,PM10,Detects matter of size 10 microns -brick:PM2.5_Level_Sensor,,,,,,brick:Sensor,PM2.5 Level,Detects level of particulates of size 2.5 microns -brick:PM2.5_Sensor,,,,,,brick:Sensor,PM2.5,Detects matter of size 2.5 microns +brick:PM1_Level_Sensor,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron +brick:PM10_Level_Sensor,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,brick:PM10,,,brick:Sensor,,Detects matter of size 10 microns +brick:PM2.5_Level_Sensor,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns +brick:PM2.5_Sensor,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns brick:Position_Command,,,,,,brick:Command,Position,Controls or reports the position of some object brick:Position_Limit,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. brick:Position_Sensor,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion @@ -656,7 +656,7 @@ brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump brick:PV_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,PV Output,See Photovoltaic_Current_Output_Sensor brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. -brick:Radon_Concentration_Sensor,,,,,,brick:Sensor,Radon Concentration,Measures the concentration of radioactivity due to radon +brick:Radon_Concentration_Sensor,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen brick:Rated_Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed @@ -791,8 +791,8 @@ brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." brick:Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. brick:Torque_Sensor,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" -brick:TVOC_Level_Sensor,,,,,,brick:Sensor,TVOC Level,A sensor measuring the level of all VOCs in air -brick:TVOC_Sensor,,,,,,brick:Sensor,TVOC, +brick:TVOC_Level_Sensor,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the level of all VOCs in air +brick:TVOC_Sensor,,,brick:VOC,,,brick:Sensor,, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air diff --git a/bricksrc/substances.py b/bricksrc/substances.py index 1215d4b3..02b03e4c 100644 --- a/bricksrc/substances.py +++ b/bricksrc/substances.py @@ -30,11 +30,17 @@ }, }, }, - "Ammonia": {}, - "CO2": {}, - "CO": {}, - "Steam": {}, + "CH2O": {}, # Formaldehyde + "CH4": {}, # Methane + "CO": {}, # Carbon monoxide + "CO2": {}, # Carbon dioxide "Natural_Gas": {}, + "NH3": {}, # Ammonia + "NO2": {}, # Nitrogen dioxide + "O3": {}, # Ozone + "Rn": {}, # Radon + "Steam": {}, + "VOC": {}, # Volatile organic compounds }, }, "Liquid": { @@ -102,4 +108,11 @@ "Soil": {}, }, }, + "Particulate_Matter": { + SKOS.narrower: { + "PM1": {}, + "PM2.5": {}, + "PM10": {}, + }, + }, } From 2d337ac70d99d0768f1e039b88af813076d37144 Mon Sep 17 00:00:00 2001 From: ektrah Date: Tue, 28 Oct 2025 18:06:40 +0100 Subject: [PATCH 11/31] Define all point attributes [no ci] --- bricksrc/points.csv | 1734 +++++++++++++++++++++---------------------- 1 file changed, 867 insertions(+), 867 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 44749260..0834d75c 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,867 +1,867 @@ -@id,brick:isAggregated,brick:ofEquipment,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/brick:hasEnumeration,rdfs:subClassOf,todo:,skos:definition -brick:Absolute_Humidity_Sensor,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity -brick:Acceleration_Time_Setpoint,,,,,,brick:Setpoint,Acceleration Time, -brick:Active_Power_Sensor,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" -brick:Adjust_Sensor,,,,,,brick:Sensor,Adjust,Measures user-provided adjustment of some value -brick:Air_Alarm,,,brick:Air,,,brick:Alarm,, -brick:Air_Differential_Pressure_Sensor,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air -brick:Air_Differential_Pressure_Setpoint,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit -brick:Air_Enthalpy_Sensor,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air -brick:Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. -brick:Air_Flow_Deadband_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow -brick:Air_Flow_Demand_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of air flow required for a process -brick:Air_Flow_Loss_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. -brick:Air_Flow_Sensor,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air -brick:Air_Flow_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow -brick:Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Air_Grains_Sensor,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air -brick:Air_Pressure_Sensor,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. -brick:Air_Pressure_Setpoint,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, -brick:Air_Quality_Sensor,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality -brick:Air_Static_Pressure_Sensor,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." -brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Air_Temperature_Alarm,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. -brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air -brick:Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air -brick:Air_Temperature_Setpoint_Limit,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. -brick:Air_Temperature_Step_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. -brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, -brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action -brick:Alarm_Delay_Parameter,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met -brick:Alarm_Sensitivity_Parameter,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. -brick:Ammonia_Sensor,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air -brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon -brick:Automatic_Mode_Command,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" -brick:Availability_Status,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" -brick:Average_Cooling_Demand_Sensor,brick:Average,,,,,brick:Sensor,Cooling Demand,Measures the average power consumed by a cooling process as the amount of power consumed over some interval -brick:Average_Discharge_Air_Flow_Sensor,brick:Average,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of discharge air over some interval -brick:Average_Exhaust_Air_Static_Pressure_Sensor,brick:Average,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time -brick:Average_Heating_Demand_Sensor,brick:Average,,,,,brick:Sensor,Heating Demand,Measures the average power consumed by a heating process as the amount of power consumed over some interval -brick:Average_Supply_Air_Flow_Sensor,brick:Average,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of supply air over some interval -brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" -brick:Battery_Voltage_Sensor,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery -brick:Boiler_Command,,brick:Boiler,,,,brick:Command,,A command to control a boiler -brick:Box_Mode_Command,,,,,,brick:Command,Box Mode, -brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building -brick:Building_Air_Static_Pressure_Sensor,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building -brick:Building_Air_Static_Pressure_Setpoint,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building -brick:Bypass_Air_Flow_Sensor,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air -brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air -brick:Bypass_Command,,,,,,brick:Command,Bypass, -brick:Bypass_Water_Flow_Sensor,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water -brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water -brick:Capacity_Sensor,,,,,quantitykind:Capacity,brick:Sensor,, -brick:Change_Filter_Alarm,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed -brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water -brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, -brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,Load Shed, -brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, -brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Chilled_Water_Differential_Pressure_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve -brick:Chilled_Water_Differential_Pressure_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water -brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, -brick:Chilled_Water_Differential_Temperature_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device -brick:Chilled_Water_Flow_Sensor,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit -brick:Chilled_Water_Flow_Setpoint,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water -brick:Chilled_Water_Gauge_Pressure_Sensor,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water -brick:Chilled_Water_Static_Pressure_Setpoint,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water -brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water,,,brick:Command,System Enable,Enables operation of the chilled water system -brick:Chilled_Water_Temperature_Sensor,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water -brick:Chilled_Water_Temperature_Setpoint,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water -brick:Close_Limit,,,,,,brick:Limit,Close,A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. -brick:CO_Differential_Sensor,,,brick:CO,brick:Differential,,brick:Sensor,, -brick:CO_Level_Sensor,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO -brick:CO_Sensor,,,brick:CO,,,brick:Sensor,,Measures properties of CO -brick:CO2_Alarm,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. -brick:CO2_Alarm_Sensitivity_Parameter,,,brick:CO2,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a CO2 alarm. -brick:CO2_Differential_Sensor,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air -brick:CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air -brick:CO2_Sensor,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air -brick:CO2_Setpoint,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 -brick:Coldest_Zone_Air_Temperature_Sensor,brick:Coldest,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' -brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" -brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" -brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" -brick:Command,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. -brick:Communication_Loss_Alarm,,,,,,brick:Loss_Alarm,Communication,An alarm that indicates a loss of communication e.g. with a device or controller -brick:Condensate_Leak_Alarm,,,,,,brick:Leak_Alarm,Condensate,An alarm that indicates a leak of condensate from a cooling system -brick:Condenser_Water_Flow_Sensor,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water -brick:Condenser_Water_Flow_Setpoint,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Condenser_Water_Temperature_Sensor,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water -brick:Conductivity_Sensor,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance -brick:Contact_Sensor,,,,,,brick:Sensor,Contact,"Senses or detects contact, such as for determining if a door is closed." -brick:Cooling_Command,,,,,,brick:Command,Cooling,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) -brick:Cooling_Demand_Sensor,,,,,,brick:Sensor,Cooling Demand,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton -brick:Cooling_Demand_Setpoint,,,,,,brick:Setpoint,Cooling Demand,Sets the rate required for cooling -brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets discharge air flow for cooling -brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of cooling discharge air -brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Cooling, -brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Cooling, -brick:Cooling_Enable_Command,,,,,,brick:Command,Cooling Enable,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." -brick:Cooling_Mode_Status,,,,,,brick:Status,Cooling Mode,"Indicates whether a system, device or control loop is in a cooling mode" -brick:Cooling_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Cooling, -brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Cooling,Sets supply air flow rate for cooling -brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Cooling,Sets the size of a deadband of temperature of supply air for cooling -brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Cooling, -brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Cooling, -brick:Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Cooling,Sets temperature for cooling -brick:Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Cooling,The cooling setpoint for a specific zone in a building. -brick:Core_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. -brick:Core_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." -brick:Current_Imbalance_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system -brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. -brick:Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device -brick:Current_Ratio_Setpoint,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer -brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor -brick:Curtailment_Override_Command,,,,,,brick:Override_Command,Curtailment, -brick:Cycle_Alarm,,,,,,brick:Alarm,Cycle,An alarm that indicates off-normal conditions associated with HVAC cycles -brick:Damper_Command,,brick:Damper,,,,brick:Command,,Controls properties of dampers -brick:Damper_Position_Command,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper -brick:Damper_Position_Sensor,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open -brick:Damper_Position_Setpoint,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper -brick:Damper_Position_Status,,brick:Damper,,,,brick:Status,Position, -brick:DC_Bus_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,DC Bus,Measures the voltage across a DC bus -brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband -brick:Deceleration_Time_Setpoint,,,,,,brick:Setpoint,Deceleration Time, -brick:Dehumidification_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, -brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" -brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. -brick:Deionized_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water -brick:Deionized_Water_Level_Sensor,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container -brick:Delay_Parameter,,,,,,brick:Parameter,Delay,A parameter determining how long to delay a subsequent action to take place after a received signal -brick:Demand_Sensor,,,,,,brick:Sensor,Demand,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton -brick:Demand_Setpoint,,,,,,brick:Setpoint,Demand,Sets the rate required for a process -brick:Derivative_Gain_Parameter,,,,,,brick:Parameter,Derivative Gain, -brick:Derivative_Time_Parameter,,,,,,brick:Parameter,Derivative Time, -brick:Dewpoint_Sensor,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor -brick:Dewpoint_Setpoint,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point -brick:Differential_Air_Temperature_Setpoint,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit -brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure -brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Differential_Pressure_Load_Shed_Status,,,,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, -brick:Differential_Pressure_Proportional_Band_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures -brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure -brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. -brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, -brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements -brick:Differential_Speed_Sensor,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, -brick:Differential_Speed_Setpoint,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed -brick:Differential_Temperature_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements -brick:Direction_Command,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon -brick:Direction_Sensor,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring -brick:Direction_Status,,,,,,brick:Status,Direction,Indicates which direction a device is operating in -brick:Disable_Command,,,,,,brick:Command,Disable,Commands that disable functionality -brick:Disable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Disable,Disables the use of differential enthalpy control -brick:Disable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Command,Disable,Disables the use of differential temperature control -brick:Disable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Command,Disable Fixed,Disables the use of fixed enthalpy control -brick:Disable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Command,Disable Fixed,Disables the use of fixed temperature temperature -brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Disable System Outside Air,Disables hot water system when outside air temperature reaches the indicated value -brick:Disable_Status,,,,,,brick:Status,Disable,Indicates if functionality has been disabled -brick:Discharge_Air_Dewpoint_Sensor,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air -brick:Discharge_Air_Differential_Pressure_Sensor,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, -brick:Discharge_Air_Differential_Pressure_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Discharge_Air_Duct_Pressure_Status,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds -brick:Discharge_Air_Flow_Demand_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of discharge air flow required for a process -brick:Discharge_Air_Flow_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,High, -brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,Low, -brick:Discharge_Air_Flow_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies -brick:Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air -brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow -brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air -brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air -brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, -brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, -brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Discharge_Air,,,brick:Alarm,Smoke Detection, -brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air -brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, -brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Discharge_Air_Static_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system -brick:Discharge_Air_Static_Pressure_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air -brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. -brick:Discharge_Air_Temperature_Cooling_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Cooling,Sets temperature of discharge air for cooling -brick:Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air -brick:Discharge_Air_Temperature_Heating_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Heating,Sets temperature of discharge air for heating -brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, -brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air -brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air -brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, -brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. -brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water -brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water,,,brick:Command,System Enable,Enables operation of the domestic hot water system -brick:Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water -brick:Drive_Ready_Status,,,,,,brick:Status,Drive Ready,"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" -brick:Duct_Air_Static_Pressure_Setpoint,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, -brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,EconCycle, -brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Effective, -brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Cooling,The effective cooling setpoint for a specific zone in a building. -brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Effective, -brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Heating,The effective heating setpoint for a specific zone in a building. -brick:Effective_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Effective, -brick:Effective_Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Effective Room, -brick:Effective_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Effective, -brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Effective Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width -brick:Electric_Energy_Sensor,,,,,,brick:Sensor,Electric Energy, -brick:Electric_Power_Sensor,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed -brick:Electrical_Energy_Usage_Sensor,,,,,,brick:Sensor,Electrical Energy Usage,A sensor that records the quantity of electrical energy consumed in a given period -brick:Embedded_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. -brick:Embedded_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." -brick:Emergency_Air_Flow_System_Status,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Status,Emergency System, -brick:Emergency_Alarm,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems -brick:Emergency_Generator_Alarm,,,,,,brick:Alarm,Emergency Generator,An alarm that indicates off-normal conditions associated with an emergency generator -brick:Emergency_Generator_Status,,,,,,brick:Status,Emergency Generator,Indicates if an emergency generator is active -brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,quantitykind:Power,brick:Status,Emergency Off System Activated By High Temperature, -brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,quantitykind:Power,brick:Status,Emergency Off System Activated By Leak Detection, -brick:Emergency_Power_Off_System_Status,,,,,quantitykind:Power,brick:Status,Emergency Off System, -brick:Emergency_Push_Button_Status,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed -brick:Enable_Command,,,,,,brick:Command,Enable,Commands that enable functionality -brick:Enable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Enable,Enables the use of differential enthalpy control -brick:Enable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Command,Enable,Enables the use of differential temperature control -brick:Enable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Command,Enable Fixed,Enables the use of fixed enthalpy control -brick:Enable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Command,Enable Fixed,Enables the use of fixed temperature control -brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Enable System Outside Air,Enables hot water system when outside air temperature reaches the indicated value -brick:Enable_Status,,,,,,brick:Status,Enable,Indicates if a system or piece of functionality has been enabled -brick:Energy_Generation_Sensor,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. -brick:Energy_Sensor,,,,,,brick:Sensor,Energy,Measures energy consumption -brick:Energy_Usage_Sensor,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time -brick:Entering_Chilled_Water_Flow_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water -brick:Entering_Chilled_Water_Flow_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water -brick:Entering_Chilled_Water_Temperature_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower -brick:Entering_Chilled_Water_Temperature_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water -brick:Entering_Condenser_Water_Flow_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water -brick:Entering_Condenser_Water_Temperature_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water -brick:Entering_Condenser_Water_Temperature_Setpoint,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water -brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering, -brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering, -brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering High Temperature,Measures the temperature of high-temperature hot water enteringed to a hot water system -brick:Entering_Hot_Water_Flow_Sensor,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water -brick:Entering_Hot_Water_Flow_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water -brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,Load Shed, -brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Entering_Hot_Water_Temperature_Sensor,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system -brick:Entering_Hot_Water_Temperature_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water -brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering Medium Temperature High, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering Medium Temperature Load Shed, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Hot_Water,,quantitykind:Temperature,brick:Status,Entering Medium Temperature Load Shed, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering Medium Temperature Low, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering Medium Temperature,Measures the temperature of medium-temperature hot water entering a hot water system -brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water -brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Entering_Water_Flow_Sensor,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system -brick:Entering_Water_Flow_Setpoint,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water -brick:Entering_Water_Pressure_Sensor,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. -brick:Entering_Water_Temperature_Alarm,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. -brick:Entering_Water_Temperature_Deadband_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water -brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water -brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water -brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance -brick:Enthalpy_Setpoint,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy -brick:Even_Month_Status,,,,,,brick:Status,Even Month, -brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air -brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building -brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit -brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, -brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, -brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air -brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate -brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air -brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air -brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow -brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, -brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, -brick:Exhaust_Air_Stack_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack -brick:Exhaust_Air_Stack_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate -brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system -brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air -brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air -brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, -brick:Failure_Alarm,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" -brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans -brick:Fan_On_Off_Status,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, -brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans -brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans -brick:Fault_Reset_Command,,,,,,brick:Reset_Command,Fault,Clears a fault status -brick:Fault_Status,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" -brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. -brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter -brick:Filter_Reset_Command,,brick:Filter,,,,brick:Reset_Command,, -brick:Filter_Status,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced -brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. -brick:Fire_Sensor,,,,,,brick:Sensor,Fire,Measures the presence of fire -brick:Flow_Sensor,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance -brick:Flow_Setpoint,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow -brick:Formaldehyde_Level_Sensor,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen -brick:Frequency_Command,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) -brick:Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" -brick:Frequency_Setpoint,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency -brick:Fresh_Air_Setpoint_Limit,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Frost_Sensor,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost -brick:Fume_Hood_Air_Flow_Sensor,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood -brick:Gain_Parameter,,,,,,brick:Parameter,Gain, -brick:Gas_Sensor,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) -brick:Gauge_Pressure_Sensor,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure -brick:Generation_Sensor,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. -brick:Hail_Sensor,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential -brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger,,,,brick:Status,System Enable,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. -brick:Heating_Command,,,,,,brick:Command,Heating,Controls the amount of heating to be delivered (typically as a proportion of total heating output) -brick:Heating_Demand_Sensor,,,,,,brick:Sensor,Heating Demand,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton -brick:Heating_Demand_Setpoint,,,,,,brick:Setpoint,Heating Demand,Sets the rate required for heating -brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets discharge air flow for heating -brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of heating discharge air -brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Heating, -brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Heating, -brick:Heating_Enable_Command,,,,,,brick:Command,Heating Enable,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." -brick:Heating_Mode_Status,,,,,,brick:Status,Heating Mode,"Indicates whether a system, device or control loop is in a heating mode" -brick:Heating_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Heating, -brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Heating,Sets supply air flow rate for heating -brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,Heating,Sets the size of a deadband of temperature of supply air for heating -brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,Heating, -brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,Heating, -brick:Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Heating,Sets temperature for heating -brick:Heating_Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Heating Thermal, -brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Heating,The heating setpoint for a specific zone in a building. -brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,High,An alarm that indicates that the air flow is higher than normal. -brick:High_CO2_Alarm,,,brick:CO2,,,brick:Alarm,High,A device that indicates high concentration of carbon dioxide. -brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,High Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. -brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,High,An alarm that indicates high concentration of water vapor in the air. -brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,High,A parameter determining the humidity level at which to trigger a high humidity alarm -brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,High Lockout,The upper bound of the outside air temperature lockout range -brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates that return air temperature is too high -brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,High Cutout,A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. -brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,High, -brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,High,An alarm that indicates high temperature. -brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Parameter,High,A parameter determining the temperature level at which to trigger a high temperature alarm -brick:Hold_Status,,,,,,brick:Status,Hold, -brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water -brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed Reset, -brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,Load Shed, -brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve -brick:Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water -brick:Hot_Water_Differential_Temperature_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device -brick:Hot_Water_Flow_Sensor,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit -brick:Hot_Water_Flow_Setpoint,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water -brick:Hot_Water_Gauge_Pressure_Sensor,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water -brick:Hot_Water_Static_Pressure_Setpoint,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air -brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water,,,brick:Command,System Enable,Enables operation of the hot water system -brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water -brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" -brick:Humidification_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Humidification, -brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier -brick:Humidify_Command,,,,,,brick:Command,Humidify, -brick:Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. -brick:Humidity_Deadband_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity -brick:Humidity_Parameter,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points -brick:Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air -brick:Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity -brick:Humidity_Tolerance_Parameter,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. -brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Tank,brick:Ice,,quantitykind:Temperature,brick:Sensor,Leaving Water,Measures the temperature of water leaving an ice tank -brick:Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" -brick:Illuminance_Setpoint,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. -brick:Imbalance_Sensor,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system -brick:Inside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. -brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. -brick:Intake_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Intake,Measures air at the interface between the building and the outside -brick:Integral_Gain_Parameter,,,,,,brick:Parameter,Integral Gain, -brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred -brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation -brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled -brick:Lead_On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" -brick:Leak_Alarm,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids -brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water -brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water -brick:Leaving_Chilled_Water_Temperature_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller -brick:Leaving_Chilled_Water_Temperature_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water -brick:Leaving_Condenser_Water_Flow_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water -brick:Leaving_Condenser_Water_Temperature_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water -brick:Leaving_Condenser_Water_Temperature_Setpoint,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water -brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of domestic water supplied by a hot water system -brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving,Sets temperature of leavinging part of domestic hot water -brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving High Temperature,Measures the temperature of high-temperature hot water supplied by a hot water system -brick:Leaving_Hot_Water_Flow_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water -brick:Leaving_Hot_Water_Flow_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water -brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,Load Shed, -brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Leaving_Hot_Water_Temperature_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system -brick:Leaving_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving Medium Temperature High, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving Medium Temperature Load Shed, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Hot_Water,,quantitykind:Temperature,brick:Status,Leaving Medium Temperature Load Shed, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving Medium Temperature Low, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving Medium Temperature,Measures the temperature of medium-temperature hot water supplied by a hot water system -brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water -brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Leaving_Water_Flow_Sensor,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system -brick:Leaving_Water_Flow_Setpoint,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water -brick:Leaving_Water_Pressure_Sensor,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. -brick:Leaving_Water_Temperature_Alarm,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. -brick:Leaving_Water_Temperature_Deadband_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water -brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system -brick:Leaving_Water_Temperature_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water -brick:Level_Command,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. -brick:Level_Status,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. -brick:Lighting_Correlated_Color_Temperature_Command,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. -brick:Lighting_Correlated_Color_Temperature_Sensor,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. -brick:Lighting_Level_Command,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. -brick:Limit,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point -brick:Liquid_Detection_Alarm,,,brick:Liquid,,,brick:Alarm,Detection, -brick:Load_Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load -brick:Load_Parameter,,,,,,brick:Parameter,Load, -brick:Load_Setpoint,,,,,,brick:Setpoint,Load, -brick:Load_Shed_Command,,,,,,brick:Command,Load Shed,Controls load shedding behavior provided by a control system -brick:Load_Shed_Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,Load Shed, -brick:Load_Shed_Setpoint,,,,,,brick:Setpoint,Load Shed, -brick:Load_Shed_Status,,,,,,brick:Status,Load Shed,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Locally, -brick:Lockout_Status,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" -brick:Lockout_Temperature_Differential_Parameter,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, -brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low,An alarm that indicates that the air flow is lower than normal. -brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Alarm,Low,An alarm that indicates the battery is low. -brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low,An alarm that indicates that the discharge air flow is lower than normal. -brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,Low, -brick:Low_Freeze_Protect_Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Low Freeze Protect, -brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,Low,An alarm that indicates low concentration of water vapor in the air. -brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,Low,A parameter determining the humidity level at which to trigger a low humidity alarm -brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Low Lockout,The lower bound of the outside air temperature lockout range -brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Low Enable, -brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Low Enable, -brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,Low,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,Low Suction,An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. -brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,Low, -brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,Low, -brick:Low_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,Low,An alarm that indicates low temperature. -brick:Low_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Parameter,Low,A parameter determining the temperature level at which to trigger a low temperature alarm -brick:Low_Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,Low,An alarm that indicates the voltage is lower than its normal state. -brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,Lowest,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time -brick:Luminance_Alarm,,,,,quantitykind:Luminance,brick:Alarm,, -brick:Luminance_Command,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system -brick:Luminance_Sensor,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction -brick:Luminance_Setpoint,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance -brick:Maintenance_Mode_Command,,,,,,brick:Command,Maintenance Mode,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" -brick:Maintenance_Required_Alarm,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment -brick:Manual_Auto_Status,,,,,,brick:Status,Manual Auto,Indicates if a system is under manual or automatic operation -brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Max_Air_Temperature_Setpoint,brick:Maximum,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature -brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. -brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. -brick:Max_Discharge_Air_Temperature_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Max_Frequency_Command,brick:Maximum,,,,quantitykind:Frequency,brick:Command,,Sets the maximum permitted frequency -brick:Max_Fresh_Air_Setpoint_Limit,brick:Maximum,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. -brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. -brick:Max_Limit,brick:Maximum,,,,,brick:Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. -brick:Max_Load_Setpoint,brick:Maximum,,,,,brick:Setpoint,Load, -brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. -brick:Max_Outside_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. -brick:Max_Position_Setpoint_Limit,brick:Maximum,,,,,brick:Setpoint_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. -brick:Max_Speed_Setpoint_Limit,brick:Maximum,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. -brick:Max_Static_Pressure_Setpoint_Limit,brick:Maximum,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. -brick:Max_Supply_Air_Temperature_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Max_Temperature_Setpoint_Limit,brick:Maximum,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. -brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. -brick:Max_Water_Level_Alarm,brick:Maximum,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the maximum water level was reached -brick:Max_Water_Temperature_Setpoint,brick:Maximum,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for max water temperature -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Status,Medium Pressure Load Shed Reset, -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,Medium Pressure Load Shed, -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Status,Medium Pressure Load Shed, -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Medium Pressure,Measures the difference in water pressure between sections of a medium temperature hot water system -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,Medium Pressure, -brick:Methane_Level_Sensor,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air -brick:Min_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Min_Air_Temperature_Setpoint,brick:Minimum,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for minimum air temperature -brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. -brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Cooling,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. -brick:Min_Discharge_Air_Temperature_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Min_Frequency_Command,brick:Minimum,,,,quantitykind:Frequency,brick:Command,, -brick:Min_Fresh_Air_Setpoint_Limit,brick:Minimum,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Heating,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. -brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. -brick:Min_Limit,brick:Minimum,,,,,brick:Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. -brick:Min_Load_Setpoint,brick:Minimum,,,,,brick:Setpoint,Load, -brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Cooling,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Occupied Heating,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. -brick:Min_Outside_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. -brick:Min_Position_Setpoint_Limit,brick:Minimum,,,,,brick:Setpoint_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. -brick:Min_Speed_Setpoint_Limit,brick:Minimum,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. -brick:Min_Static_Pressure_Setpoint_Limit,brick:Minimum,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. -brick:Min_Supply_Air_Temperature_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Min_Temperature_Setpoint_Limit,brick:Minimum,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. -brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Cooling,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,Unoccupied Heating,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. -brick:Min_Water_Level_Alarm,brick:Minimum,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the minimum water level was reached -brick:Min_Water_Temperature_Setpoint,brick:Minimum,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for min water temperature -brick:Mixed_Air_Flow_Sensor,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air -brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air -brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air -brick:Mixed_Air_Temperature_Sensor,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air -brick:Mixed_Air_Temperature_Setpoint,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air -brick:Mode_Command,,,,,,brick:Command,Mode,Controls the operating mode of a device or controller -brick:Mode_Status,,,,,,brick:Status,Mode,"Indicates which mode a system, device or control loop is currently in" -brick:Motion_Sensor,,,,,,brick:Sensor,Motion,Detects the presence of motion in some area -brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor -brick:Motor_Direction_Status,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" -brick:Motor_On_Off_Status,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, -brick:Motor_Speed_Sensor,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, -brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" -brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas -brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas -brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system -brick:NO2_Level_Sensor,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air -brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" -brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area -brick:Occupancy_Sensor,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area -brick:Occupancy_Status,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied -brick:Occupied_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Occupied, -brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Cooling,Sets discharge air flow for cooling when occupied -brick:Occupied_Cooling_Mode_Status,,,,,,brick:Status,Occupied Cooling Mode, -brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Cooling,Sets supply air flow rate for cooling when occupied -brick:Occupied_Cooling_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Occupied Cooling,Sets the size of a deadband of temperature for cooling when occupied -brick:Occupied_Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Occupied Cooling,Sets temperature for cooling when occupied -brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Cooling,Sets temperature for zone air cooling when occupied -brick:Occupied_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied,Sets discharge air flow when occupied -brick:Occupied_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, -brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Heating,Sets discharge air flow for heating when occupied -brick:Occupied_Heating_Mode_Status,,,,,,brick:Status,Occupied Heating Mode, -brick:Occupied_Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied Heating,Sets supply air flow rate for heating when occupied -brick:Occupied_Heating_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Occupied Heating,Sets the size of a deadband of temperature for heating when occupied -brick:Occupied_Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Occupied Heating,Sets temperature for heating when occupied -brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Heating,Sets temperature for zone air heating when occupied -brick:Occupied_Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,Occupied,Target humidity level when the location is occupied. -brick:Occupied_Load_Shed_Command,,,,,,brick:Command,Occupied Load Shed, -brick:Occupied_Mode_Status,,,,,,brick:Status,Occupied Mode,"Indicates if a system, device or control loop is in ""Occupied"" mode" -brick:Occupied_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, -brick:Occupied_Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Occupied Room, -brick:Occupied_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Occupied,Sets supply air flow rate when occupied -brick:Occupied_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Occupied, -brick:Occupied_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Occupied Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. -brick:Off_Command,,,,,,brick:Command,Off,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" -brick:Off_Status,,,,,,brick:Status,Off,"Indicates if a control loop, relay or equipment is off" -brick:On_Command,,,,,,brick:Command,On,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" -brick:On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" -brick:On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" -brick:On_Status,,,,,,brick:Status,On,"Indicates if a control loop, relay or equipment is on" -brick:On_Timer_Sensor,,,,,,brick:Sensor,On Timer,"Measures the duration for which a device was in an active or ""on"" state" -brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" -brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve -brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, -brick:Operating_Mode_Status,,,,,,brick:Status,Operating Mode,"Indicates the current operating mode of a system, device or control loop" -brick:Output_Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,Output, -brick:Output_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device -brick:Outside_Air_CO_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air -brick:Outside_Air_CO2_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air -brick:Outside_Air_Dewpoint_Sensor,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air -brick:Outside_Air_Enthalpy_Sensor,,,brick:Outside_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air -brick:Outside_Air_Flow_Sensor,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system -brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate -brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air -brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air -brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air -brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, -brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, -brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, -brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air -brick:Outside_Air_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air -brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air -brick:Outside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. -brick:Outside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. -brick:Outside_Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" -brick:Overload_Alarm,,,,,,brick:Alarm,Overload,An alarm that can indicate when a full-load current is exceeded. -brick:Overridden_Off_Status,,,,,,brick:Status,Overridden Off,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" -brick:Overridden_On_Status,,,,,,brick:Status,Overridden On,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" -brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden -brick:Override_Command,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' -brick:Ozone_Level_Sensor,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air -brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values -brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air -brick:Peak_Demand_Sensor,brick:Peak,,,,,brick:Sensor,Demand,The peak power consumed by a process over some period of time -brick:Photovoltaic_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Photovoltaic Output,Senses the amperes of electrical current produced as output by a photovoltaic device -brick:PID_Parameter,,,,,,brick:Parameter,PID, -brick:Piezoelectric_Sensor,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" -brick:PIR_Sensor,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors -brick:PM1_Level_Sensor,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns -brick:PM1_Sensor,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron -brick:PM10_Level_Sensor,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns -brick:PM10_Sensor,,,brick:PM10,,,brick:Sensor,,Detects matter of size 10 microns -brick:PM2.5_Level_Sensor,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns -brick:PM2.5_Sensor,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns -brick:Position_Command,,,,,,brick:Command,Position,Controls or reports the position of some object -brick:Position_Limit,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. -brick:Position_Sensor,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion -brick:Power_Alarm,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. -brick:Power_Factor_Sensor,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." -brick:Power_Loss_Alarm,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. -brick:Power_Sensor,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed -brick:Pre_Filter_Status,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced -brick:Preheat_Command,,,,,,brick:Command,Preheat,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer -brick:Preheat_Demand_Setpoint,,,,,,brick:Setpoint,Preheat Demand,Sets the rate required for preheat -brick:Preheat_Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of discharge air before heating is applied -brick:Preheat_Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of supply air before it is heated -brick:Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. -brick:Pressure_Sensor,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area -brick:Pressure_Setpoint,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure -brick:Pressure_Status,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds -brick:Proportional_Band_Parameter,,,,,,brick:Proportional_Band_Parameter,, -brick:Proportional_Gain_Parameter,,,,,,brick:Proportional_Gain_Parameter,, -brick:Pump_Command,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) -brick:Pump_On_Off_Status,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, -brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump -brick:PV_Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,PV Output,See Photovoltaic_Current_Output_Sensor -brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. -brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. -brick:Radon_Concentration_Sensor,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon -brick:Rain_Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame -brick:Rain_Level_Sensor,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed -brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power -brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" -brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, -brick:Reheat_Command,,,,,,brick:Command,Reheat,"A command to activate reheating, which is used for either heating or for dehumidification purposes" -brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature -brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Remotely, -brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" -brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies -brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air -brick:Return_Air_CO2_Sensor,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air -brick:Return_Air_CO2_Setpoint,,,brick:Return_Air,,,brick:Setpoint,CO2,Sets some property of CO2 in Return Air -brick:Return_Air_Dewpoint_Sensor,,,brick:Return_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air -brick:Return_Air_Differential_Pressure_Sensor,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side -brick:Return_Air_Differential_Pressure_Setpoint,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit -brick:Return_Air_Enthalpy_Sensor,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air -brick:Return_Air_Flow_Sensor,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air -brick:Return_Air_Grains_Sensor,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air -brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air -brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air -brick:Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. -brick:Return_Air_Temperature_High_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Return_Air_Temperature_Low_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Return_Air_Temperature_Sensor,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air -brick:Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" -brick:Room_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Room, -brick:Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Room,Sets temperature of room air -brick:Run_Enable_Command,,,,,,brick:Command,Run Enable, -brick:Run_Request_Status,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment -brick:Run_Status,,,,,,brick:Status,Run, -brick:Run_Time_Sensor,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" -brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open -brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule -brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). -brick:Sensor_Failure_Alarm,,,,,,brick:Failure_Alarm,Sensor, -brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set -brick:Short_Cycle_Alarm,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle -brick:Smoke_Alarm,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. -brick:Smoke_Detection_Alarm,,,,,,brick:Alarm,Smoke Detection, -brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil -brick:Solar_Azimuth_Angle_Sensor,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun -brick:Solar_Irradiance_Sensor,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems -brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun -brick:Speed_Command,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. -brick:Speed_Mode_Status,,,,,quantitykind:Speed,brick:Status,Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." -brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Reset_Command,, -brick:Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement -brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed -brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. -brick:Stage_Enable_Command,,,,,,brick:Command,Stage Enable,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property -brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in -brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Cooling, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Glycool Unit,Indicates the on/off status of a standby glycool unit -brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Heating, -brick:Standby_Load_Shed_Command,,,,,,brick:Command,Standby Load Shed, -brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, -brick:Standby_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Unit,Indicates the on/off status of a standby unit -brick:Start_Stop_Command,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence -brick:Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) -brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure -brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, -brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Static_Pressure_Sensor,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work -brick:Static_Pressure_Setpoint,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure -brick:Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Status,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" -brick:Steam_On_Off_Command,,,brick:Steam,,brick:EnumerationKind-On_Off,brick:Command,, -brick:Steam_Usage_Sensor,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" -brick:Step_Parameter,,,,,,brick:Step_Parameter,, -brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, -brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building -brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit -brick:Supply_Air_Duct_Pressure_Status,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds -brick:Supply_Air_Flow_Demand_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Demand,Sets the rate of supply air flow required for a process -brick:Supply_Air_Flow_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,High, -brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,Low, -brick:Supply_Air_Flow_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, -brick:Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air -brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate -brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air -brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air -brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, -brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, -brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Supply_Air,,,brick:Alarm,Smoke Detection, -brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air -brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, -brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Supply_Air_Static_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system -brick:Supply_Air_Static_Pressure_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air -brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. -brick:Supply_Air_Temperature_Cooling_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Cooling, -brick:Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air -brick:Supply_Air_Temperature_Heating_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Heating, -brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, -brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air -brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air -brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, -brick:Switch_Status,,brick:Switch,,,,brick:Status,,Status of a switch -brick:System_Enable_Command,,,,,,brick:Command,System Enable,Enables operation of a system -brick:System_Shutdown_Status,,,,,,brick:Status,System Shutdown,Indicates if a system has been shutdown -brick:System_Status,,,,,,brick:Status,System,Indicates properties of the activity of a system -brick:Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, -brick:Temperature_Adjust_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Adjust,Measures user-provided adjustment of temperature -brick:Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. -brick:Temperature_Alarm_Sensitivity_Parameter,,,,,quantitykind:Temperature,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a temperature alarm. -brick:Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature -brick:Temperature_Differential_Reset_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Temperature_High_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Reset_Setpoint,High, -brick:Temperature_Low_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Reset_Setpoint,Low, -brick:Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points -brick:Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold -brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature -brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. -brick:Temporary_Occupancy_Status,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" -brick:Thermal_Energy_Usage_Sensor,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period -brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, -brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat -brick:Time_Parameter,,,,,,brick:Parameter,Time, -brick:Time_Setpoint,,,,,,brick:Setpoint,Time, -brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. -brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." -brick:Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. -brick:Torque_Sensor,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" -brick:TVOC_Level_Sensor,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the level of all VOCs in air -brick:TVOC_Sensor,,,brick:VOC,,,brick:Sensor,, -brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum -brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure -brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air -brick:Unit_Failure_Alarm,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device -brick:Unoccupied_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied,Sets temperature of air when unoccupied -brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Cooling,Sets discharge air flow for cooling when unoccupied -brick:Unoccupied_Cooling_Mode_Status,,,,,,brick:Status,Unoccupied Cooling Mode,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" -brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Cooling, -brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Unoccupied Cooling, -brick:Unoccupied_Cooling_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Unoccupied Cooling, -brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Cooling,Sets temperature of air when unoccupied for cooling within a specific zone -brick:Unoccupied_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied, -brick:Unoccupied_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, -brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Heating, -brick:Unoccupied_Heating_Mode_Status,,,,,,brick:Status,Unoccupied Heating Mode,"Indicates whether a system, device or control loop is in an unoccupied heating mode" -brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied Heating, -brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,Unoccupied Heating, -brick:Unoccupied_Heating_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Unoccupied Heating, -brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Heating,Sets temperature of air when unoccupied for heating within a specific zone -brick:Unoccupied_Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,Unoccupied,Target humidity level when the location is unoccupied. -brick:Unoccupied_Load_Shed_Command,,,,,,brick:Command,Unoccupied Load Shed, -brick:Unoccupied_Mode_Status,,,,,,brick:Status,Unoccupied Mode, -brick:Unoccupied_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, -brick:Unoccupied_Room_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Room, -brick:Unoccupied_Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Unoccupied, -brick:Unoccupied_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied, -brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Unoccupied Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. -brick:Usage_Sensor,,,,,,brick:Sensor,Usage,"Measures the amount of some substance that is consumed or used, over some period of time" -brick:Valve_Command,,brick:Valve,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) -brick:Valve_Position_Alarm,,brick:Valve,,,,brick:Alarm,Position,An alarm that indicates that the valve position is not in a normal state. -brick:Valve_Position_Command,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve -brick:Valve_Position_Sensor,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open -brick:Valve_Status,,brick:Valve,,,,brick:Status,,The current status of the valve. -brick:Velocity_Pressure_Sensor,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure -brick:Velocity_Pressure_Setpoint,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,brick:Status,Vent Operating Mode,Indicates the current operating mode of a vent -brick:Ventilation_Air_Flow_Ratio_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. -brick:VFD_Enable_Command,,brick:VFD,,,,brick:Command,Enable,Enables operation of a variable frequency drive -brick:Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. -brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system -brick:Voltage_Ratio_Setpoint,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer -brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object -brick:Warm_Cool_Adjust_Sensor,,,,,,brick:Sensor,Warm Cool Adjust,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" -brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' -brick:Waste_Amount_Sensor,,,,,,brick:Sensor,Waste Amount,A metric used for measuring the quantity of waste generated in a building. -brick:Water_Alarm,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" -brick:Water_Differential_Pressure_Sensor,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. -brick:Water_Differential_Pressure_Setpoint,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit -brick:Water_Differential_Temperature_Sensor,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit -brick:Water_Differential_Temperature_Setpoint,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit -brick:Water_Flow_Sensor,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water -brick:Water_Flow_Setpoint,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water -brick:Water_Level_Alarm,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin -brick:Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container -brick:Water_Loss_Alarm,,,brick:Water,,,brick:Loss_Alarm,,An alarm that indicates a loss of water e.g. during transport -brick:Water_Pressure_Sensor,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. -brick:Water_Pressure_Setpoint,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, -brick:Water_Temperature_Alarm,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. -brick:Water_Temperature_Sensor,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water -brick:Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water -brick:Water_Usage_Sensor,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" -brick:Wind_Direction_Sensor,,,,,,brick:Sensor,Wind Direction,Measures the direction of wind in degrees relative to North -brick:Wind_Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,Wind,"Measured speed of wind, caused by air moving from high to low pressure" -brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,,brick:Status,Conditioning Mode,Indicates the mode of AC for a zone -brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air -brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air -brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air -brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone -brick:Zone_CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone -brick:Zone_Occupied_Load_Shed_Command,,,,,,brick:Command,Zone Occupied Load Shed, -brick:Zone_Standby_Load_Shed_Command,,,,,,brick:Command,Zone Standby Load Shed, -brick:Zone_Unoccupied_Load_Shed_Command,,,,,,brick:Command,Zone Unoccupied Load Shed, +@id,brick:isAggregated,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition +brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity +brick:Acceleration_Time_Setpoint,,,,,,,brick:Setpoint,Acceleration Time, +brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" +brick:Adjust_Sensor,,,,,,,brick:Sensor,Adjust,Measures user-provided adjustment of some value +brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, +brick:Air_Differential_Pressure_Sensor,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air +brick:Air_Differential_Pressure_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit +brick:Air_Enthalpy_Sensor,,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air +brick:Air_Flow_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. +brick:Air_Flow_Deadband_Setpoint,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow +brick:Air_Flow_Demand_Setpoint,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of air flow required for a process +brick:Air_Flow_Loss_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. +brick:Air_Flow_Sensor,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air +brick:Air_Flow_Setpoint,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow +brick:Air_Flow_Setpoint_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Air_Grains_Sensor,,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air +brick:Air_Pressure_Sensor,,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. +brick:Air_Pressure_Setpoint,,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, +brick:Air_Quality_Sensor,,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality +brick:Air_Static_Pressure_Sensor,,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." +brick:Air_Static_Pressure_Step_Parameter,,,,brick:Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Air_Temperature_Alarm,,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. +brick:Air_Temperature_Integral_Time_Parameter,,,,brick:Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air +brick:Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air +brick:Air_Temperature_Setpoint_Limit,,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. +brick:Air_Temperature_Step_Parameter,,,,brick:Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Air_Velocity_Pressure_Sensor,,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. +brick:Air_Wet_Bulb_Temperature_Sensor,,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, +brick:Alarm,,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action +brick:Alarm_Delay_Parameter,,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met +brick:Alarm_Sensitivity_Parameter,,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. +brick:Ammonia_Sensor,,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air +brick:Angle_Sensor,,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon +brick:Automatic_Mode_Command,,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" +brick:Availability_Status,,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" +brick:Average_Cooling_Demand_Sensor,brick:Average,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the average power consumed by a cooling process as the amount of power consumed over some interval +brick:Average_Discharge_Air_Flow_Sensor,brick:Average,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of discharge air over some interval +brick:Average_Exhaust_Air_Static_Pressure_Sensor,brick:Average,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Average_Heating_Demand_Sensor,brick:Average,,brick:Heating,,,,brick:Demand_Sensor,,Measures the average power consumed by a heating process as the amount of power consumed over some interval +brick:Average_Supply_Air_Flow_Sensor,brick:Average,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of supply air over some interval +brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" +brick:Battery_Voltage_Sensor,,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery +brick:Boiler_Command,,,brick:Boiler,,,,brick:Command,,A command to control a boiler +brick:Box_Mode_Command,,,,,,,brick:Command,Box Mode, +brick:Building_Air_Humidity_Setpoint,,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building +brick:Building_Air_Static_Pressure_Sensor,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building +brick:Building_Air_Static_Pressure_Setpoint,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building +brick:Bypass_Air_Flow_Sensor,,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air +brick:Bypass_Air_Humidity_Setpoint,,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air +brick:Bypass_Command,,,,,,,brick:Command,Bypass, +brick:Bypass_Water_Flow_Sensor,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water +brick:Bypass_Water_Flow_Setpoint,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water +brick:Capacity_Sensor,,,,,,quantitykind:Capacity,brick:Sensor,, +brick:Change_Filter_Alarm,,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed +brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water +brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Chilled_Water_Differential_Pressure_Sensor,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve +brick:Chilled_Water_Differential_Pressure_Setpoint,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water +brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Chilled_Water_Differential_Temperature_Sensor,,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device +brick:Chilled_Water_Flow_Sensor,,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit +brick:Chilled_Water_Flow_Setpoint,,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water +brick:Chilled_Water_Gauge_Pressure_Sensor,,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water +brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water +brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the chilled water system +brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water +brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water +brick:Close_Limit,,,,,,,brick:Limit,Close,A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. +brick:CO_Differential_Sensor,,,,brick:CO,brick:Differential,,brick:Sensor,, +brick:CO_Level_Sensor,,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO +brick:CO_Sensor,,,,brick:CO,,,brick:Sensor,,Measures properties of CO +brick:CO2_Alarm,,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. +brick:CO2_Alarm_Sensitivity_Parameter,,,,brick:CO2,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a CO2 alarm. +brick:CO2_Differential_Sensor,,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air +brick:CO2_Level_Sensor,,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air +brick:CO2_Sensor,,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air +brick:CO2_Setpoint,,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 +brick:Coldest_Zone_Air_Temperature_Sensor,brick:Coldest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Collection_Basin_Water_Level_Alarm,,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Level_Sensor,,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Temperature_Sensor,,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Command,,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. +brick:Communication_Loss_Alarm,,,,,,brick:EnumerationKind-CommunicationState,brick:Loss_Alarm,,An alarm that indicates a loss of communication e.g. with a device or controller +brick:Condensate_Leak_Alarm,,,,brick:Condensate,,,brick:Leak_Alarm,,An alarm that indicates a leak of condensate from a cooling system +brick:Condenser_Water_Flow_Sensor,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water +brick:Condenser_Water_Flow_Setpoint,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Condenser_Water_Temperature_Sensor,,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water +brick:Conductivity_Sensor,,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance +brick:Contact_Sensor,,,,,,,brick:Sensor,Contact,"Senses or detects contact, such as for determining if a door is closed." +brick:Cooling_Command,,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) +brick:Cooling_Demand_Sensor,,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Cooling_Demand_Setpoint,,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling +brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling +brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of cooling discharge air +brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Enable_Command,,,brick:Cooling,,,brick:EnumerationKind-Enable,brick:Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Mode_Status,,,brick:Cooling,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in a cooling mode" +brick:Cooling_Start_Stop_Status,,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling +brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for cooling +brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Temperature_Setpoint,,,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling +brick:Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The cooling setpoint for a specific zone in a building. +brick:Core_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. +brick:Core_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." +brick:Current_Imbalance_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system +brick:Current_Limit,,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. +brick:Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device +brick:Current_Ratio_Setpoint,,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer +brick:Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor +brick:Curtailment_Override_Command,,,,,,,brick:Override_Command,Curtailment, +brick:Cycle_Alarm,,,,,,,brick:Alarm,Cycle,An alarm that indicates off-normal conditions associated with HVAC cycles +brick:Damper_Command,,,brick:Damper,,,,brick:Command,,Controls properties of dampers +brick:Damper_Position_Command,,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper +brick:Damper_Position_Sensor,,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open +brick:Damper_Position_Setpoint,,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper +brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, +brick:DC_Bus_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,DC Bus,Measures the voltage across a DC bus +brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband +brick:Deceleration_Time_Setpoint,,,,,,,brick:Setpoint,Deceleration Time, +brick:Dehumidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, +brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. +brick:Deionized_Water_Conductivity_Sensor,,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water +brick:Deionized_Water_Level_Sensor,,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container +brick:Delay_Parameter,,,,,,,brick:Parameter,Delay,A parameter determining how long to delay a subsequent action to take place after a received signal +brick:Demand_Sensor,,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Demand_Setpoint,,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process +brick:Derivative_Gain_Parameter,,,,,,,brick:Parameter,Derivative Gain, +brick:Derivative_Time_Parameter,,,,,,,brick:Parameter,Derivative Time, +brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor +brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point +brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure +brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Differential_Pressure_Proportional_Band_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Differential_Pressure_Sensor,,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures +brick:Differential_Pressure_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure +brick:Differential_Pressure_Setpoint_Limit,,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. +brick:Differential_Pressure_Step_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Differential_Setpoint,,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements +brick:Differential_Speed_Sensor,,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, +brick:Differential_Speed_Setpoint,,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed +brick:Differential_Temperature_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements +brick:Direction_Command,,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon +brick:Direction_Sensor,,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring +brick:Direction_Status,,,,,,,brick:Status,Direction,Indicates which direction a device is operating in +brick:Disable_Command,,,,,,,brick:Command,Disable,Commands that disable functionality +brick:Disable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Disable,Disables the use of differential enthalpy control +brick:Disable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Command,Disable,Disables the use of differential temperature control +brick:Disable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Command,Disable Fixed,Disables the use of fixed enthalpy control +brick:Disable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Command,Disable Fixed,Disables the use of fixed temperature temperature +brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Disable,Disables hot water system when outside air temperature reaches the indicated value +brick:Disable_Status,,,,,,,brick:Status,Disable,Indicates if functionality has been disabled +brick:Discharge_Air_Dewpoint_Sensor,,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air +brick:Discharge_Air_Differential_Pressure_Sensor,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, +brick:Discharge_Air_Differential_Pressure_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Discharge_Air_Duct_Pressure_Status,,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds +brick:Discharge_Air_Flow_Demand_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of discharge air flow required for a process +brick:Discharge_Air_Flow_High_Reset_Setpoint,brick:High,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Discharge_Air_Flow_Low_Reset_Setpoint,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Discharge_Air_Flow_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies +brick:Discharge_Air_Flow_Sensor,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air +brick:Discharge_Air_Flow_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow +brick:Discharge_Air_Humidity_Sensor,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air +brick:Discharge_Air_Humidity_Setpoint,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air +brick:Discharge_Air_Integral_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, +brick:Discharge_Air_Proportional_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, +brick:Discharge_Air_Smoke_Detection_Alarm,,,,brick:Discharge_Air,,,brick:Alarm,Smoke Detection, +brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Discharge_Air_Static_Pressure_Sensor,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system +brick:Discharge_Air_Static_Pressure_Setpoint,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Step_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. +brick:Discharge_Air_Temperature_Cooling_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for cooling +brick:Discharge_Air_Temperature_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air +brick:Discharge_Air_Temperature_Heating_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for heating +brick:Discharge_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Discharge_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Discharge_Air_Temperature_Sensor,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Discharge_Air_Temperature_Step_Parameter,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Discharge_Air_Velocity_Pressure_Sensor,,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. +brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water +brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water +brick:Drive_Ready_Status,,,,,,,brick:Status,Drive Ready,"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" +brick:Duct_Air_Static_Pressure_Setpoint,,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, +brick:Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event +brick:EconCycle_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,EconCycle, +brick:Effective_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. +brick:Effective_Discharge_Air_Temperature_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective heating setpoint for a specific zone in a building. +brick:Effective_Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Supply_Air_Temperature_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width +brick:Electric_Energy_Sensor,,,,,,,brick:Sensor,Electric Energy, +brick:Electric_Power_Sensor,,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed +brick:Electrical_Energy_Usage_Sensor,,,,,,,brick:Sensor,Electrical Energy Usage,A sensor that records the quantity of electrical energy consumed in a given period +brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. +brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." +brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, +brick:Emergency_Alarm,,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Generator_Alarm,,,,,,,brick:Alarm,Emergency Generator,An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,,,,,,brick:Status,Emergency Generator,Indicates if an emergency generator is active +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High,,brick:Emergency_Power_Off_System,,,quantitykind:Temperature,brick:Status,Activated By, +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, +brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, +brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed +brick:Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Enthalpy,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Temperature,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Fixed Enthalpy,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Fixed Temperature,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,brick:EnumerationKind-Enable,brick:Setpoint,Temperature,Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if a system or piece of functionality has been enabled +brick:Energy_Generation_Sensor,,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. +brick:Energy_Sensor,,,,,,,brick:Sensor,Energy,Measures energy consumption +brick:Energy_Usage_Sensor,,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time +brick:Entering_Chilled_Water_Flow_Sensor,,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water +brick:Entering_Chilled_Water_Flow_Setpoint,,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water +brick:Entering_Chilled_Water_Temperature_Sensor,,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower +brick:Entering_Chilled_Water_Temperature_Setpoint,,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water +brick:Entering_Condenser_Water_Flow_Sensor,,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Sensor,,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Setpoint,,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water +brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering, +brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering, +brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering,Measures the temperature of high-temperature hot water enteringed to a hot water system +brick:Entering_Hot_Water_Flow_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water +brick:Entering_Hot_Water_Flow_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water +brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system +brick:Entering_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,Entering, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering,Measures the temperature of medium-temperature hot water entering a hot water system +brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water +brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Flow_Sensor,,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system +brick:Entering_Water_Flow_Setpoint,,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water +brick:Entering_Water_Pressure_Sensor,,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. +brick:Entering_Water_Temperature_Alarm,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. +brick:Entering_Water_Temperature_Deadband_Setpoint,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water +brick:Entering_Water_Temperature_Integral_Time_Parameter,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Temperature_Sensor,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water +brick:Entering_Water_Temperature_Setpoint,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water +brick:Enthalpy_Sensor,,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance +brick:Enthalpy_Setpoint,,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy +brick:Even_Month_Status,,,,,,,brick:Status,Even Month, +brick:Exhaust_Air_Dewpoint_Sensor,,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air +brick:Exhaust_Air_Differential_Pressure_Sensor,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building +brick:Exhaust_Air_Differential_Pressure_Setpoint,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit +brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Flow_Sensor,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air +brick:Exhaust_Air_Flow_Setpoint,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate +brick:Exhaust_Air_Humidity_Sensor,,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air +brick:Exhaust_Air_Humidity_Setpoint,,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air +brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, +brick:Exhaust_Air_Stack_Flow_Sensor,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack +brick:Exhaust_Air_Stack_Flow_Setpoint,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate +brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Static_Pressure_Sensor,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system +brick:Exhaust_Air_Static_Pressure_Setpoint,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air +brick:Exhaust_Air_Temperature_Sensor,,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air +brick:Exhaust_Air_Velocity_Pressure_Sensor,,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Failure_Alarm,,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" +brick:Fan_Command,,,brick:Fan,,,,brick:Command,,Controls properties of fans +brick:Fan_On_Off_Status,,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Fan_Speed_Command,,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans +brick:Fan_Status,,,brick:Fan,,,,brick:Status,,Indicates properties of fans +brick:Fault_Reset_Command,,,,,,,brick:Reset_Command,Fault,Clears a fault status +brick:Fault_Status,,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" +brick:Filter_Air_Differential_Pressure_Sensor,,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. +brick:Filter_Differential_Pressure_Sensor,,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter +brick:Filter_Reset_Command,,,brick:Filter,,,,brick:Reset_Command,, +brick:Filter_Status,,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced +brick:Filter_Water_Differential_Pressure_Sensor,,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. +brick:Fire_Sensor,,,,,,,brick:Sensor,Fire,Measures the presence of fire +brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance +brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow +brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air +brick:Freeze_Status,,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen +brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) +brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" +brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency +brick:Fresh_Air_Setpoint_Limit,,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost +brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood +brick:Gain_Parameter,,,,,,,brick:Parameter,Gain, +brick:Gas_Sensor,,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) +brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure +brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. +brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential +brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger,,,brick:EnumerationKind-Enable,brick:Status,System,Indicates if the heat exchanger system has been enabled +brick:Heat_Sink_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. +brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) +brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Heating_Demand_Setpoint,,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating +brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating +brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of heating discharge air +brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Enable_Command,,,brick:Heating,,,brick:EnumerationKind-Enable,brick:Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Mode_Status,,,brick:Heating,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in a heating mode" +brick:Heating_Start_Stop_Status,,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating +brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for heating +brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Temperature_Setpoint,,,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating +brick:Heating_Thermal_Power_Sensor,,,brick:Heating,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The heating setpoint for a specific zone in a building. +brick:High_Air_Flow_Alarm,brick:High,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is higher than normal. +brick:High_CO2_Alarm,brick:High,,,brick:CO2,,,brick:Alarm,,A device that indicates high concentration of carbon dioxide. +brick:High_Discharge_Air_Temperature_Alarm,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that discharge air temperature is too high +brick:High_Head_Pressure_Alarm,brick:High,,,,,quantitykind:Pressure,brick:Alarm,Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Humidity_Alarm,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The upper bound of the outside air temperature lockout range +brick:High_Return_Air_Temperature_Alarm,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too high +brick:High_Static_Pressure_Cutout_Setpoint_Limit,brick:High,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,Cutout,A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. +brick:High_Supply_Air_Temperature_Alarm,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, +brick:High_Temperature_Alarm,brick:High,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates high temperature. +brick:High_Temperature_Alarm_Parameter,brick:High,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm +brick:Hold_Status,,,,,,,brick:Status,Hold, +brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water +brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Hot_Water_Differential_Pressure_Sensor,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve +brick:Hot_Water_Differential_Pressure_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water +brick:Hot_Water_Differential_Temperature_Sensor,,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device +brick:Hot_Water_Flow_Sensor,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit +brick:Hot_Water_Flow_Setpoint,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water +brick:Hot_Water_Gauge_Pressure_Sensor,,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water +brick:Hot_Water_Static_Pressure_Setpoint,,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air +brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the hot water system +brick:Hot_Water_Temperature_Setpoint,,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water +brick:Hot_Water_Usage_Sensor,,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" +brick:Humidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Humidification, +brick:Humidifier_Fault_Status,,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier +brick:Humidify_Command,,,,,,,brick:Command,Humidify, +brick:Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. +brick:Humidity_Deadband_Setpoint,,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity +brick:Humidity_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points +brick:Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air +brick:Humidity_Setpoint,,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity +brick:Humidity_Tolerance_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. +brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,,brick:Tank,brick:Ice,,quantitykind:Temperature,brick:Sensor,Leaving Water,Measures the temperature of water leaving an ice tank +brick:Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" +brick:Illuminance_Setpoint,,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. +brick:Imbalance_Sensor,,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system +brick:Inside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. +brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. +brick:Intake_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Intake,Measures air at the interface between the building and the outside +brick:Integral_Gain_Parameter,,,,,,,brick:Parameter,Integral Gain, +brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, +brick:Last_Fault_Code_Status,,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred +brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation +brick:Lead_Lag_Status,,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled +brick:Lead_On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" +brick:Leak_Alarm,,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids +brick:Leaving_Chilled_Water_Flow_Sensor,,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water +brick:Leaving_Chilled_Water_Flow_Setpoint,,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water +brick:Leaving_Chilled_Water_Temperature_Sensor,,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller +brick:Leaving_Chilled_Water_Temperature_Setpoint,,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water +brick:Leaving_Condenser_Water_Flow_Sensor,,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Sensor,,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Setpoint,,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water +brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of domestic water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving,Sets temperature of leavinging part of domestic hot water +brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of high-temperature hot water supplied by a hot water system +brick:Leaving_Hot_Water_Flow_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water +brick:Leaving_Hot_Water_Flow_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water +brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system +brick:Leaving_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,Leaving, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of medium-temperature hot water supplied by a hot water system +brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water +brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Flow_Sensor,,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system +brick:Leaving_Water_Flow_Setpoint,,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water +brick:Leaving_Water_Pressure_Sensor,,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. +brick:Leaving_Water_Temperature_Alarm,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. +brick:Leaving_Water_Temperature_Deadband_Setpoint,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water +brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Temperature_Sensor,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system +brick:Leaving_Water_Temperature_Setpoint,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water +brick:Level_Command,,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. +brick:Level_Status,,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. +brick:Lighting_Correlated_Color_Temperature_Command,,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Correlated_Color_Temperature_Sensor,,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Level_Command,,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. +brick:Limit,,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point +brick:Liquid_Detection_Alarm,,,,brick:Liquid,,,brick:Alarm,Detection, +brick:Load_Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load +brick:Load_Parameter,,,,,,,brick:Parameter,Load, +brick:Load_Setpoint,,,,,,,brick:Setpoint,Load, +brick:Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,,Controls load shedding behavior provided by a control system +brick:Load_Shed_Differential_Pressure_Setpoint,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Load_Shed_Setpoint,,,brick:Load_Shed,,,,brick:Setpoint,, +brick:Load_Shed_Status,,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect +brick:Locally_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Locally, +brick:Lockout_Status,,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Low_Air_Flow_Alarm,brick:Low,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is lower than normal. +brick:Low_Battery_Alarm,brick:Low,,brick:Battery,,,,brick:Alarm,,An alarm that indicates the battery is low. +brick:Low_Discharge_Air_Flow_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the discharge air flow is lower than normal. +brick:Low_Discharge_Air_Temperature_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,, +brick:Low_Freeze_Protect_Temperature_Parameter,brick:Low,,,,,quantitykind:Temperature,brick:Parameter,Freeze Protect, +brick:Low_Humidity_Alarm,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, +brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable, +brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low +brick:Low_Suction_Pressure_Alarm,brick:Low,,,,,quantitykind:Pressure,brick:Alarm,Suction,An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Supply_Air_Flow_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,, +brick:Low_Supply_Air_Temperature_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, +brick:Low_Temperature_Alarm,brick:Low,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates low temperature. +brick:Low_Temperature_Alarm_Parameter,brick:Low,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm +brick:Low_Voltage_Alarm,brick:Low,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is lower than its normal state. +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,Lowest,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Luminance_Alarm,,,,,,quantitykind:Luminance,brick:Alarm,, +brick:Luminance_Command,,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system +brick:Luminance_Sensor,,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction +brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance +brick:Maintenance_Mode_Command,,,,,,,brick:Command,Maintenance Mode,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" +brick:Maintenance_Required_Alarm,,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Manual_Auto_Status,,,,,,,brick:Status,Manual Auto,Indicates if a system is under manual or automatic operation +brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Max_Air_Temperature_Setpoint,brick:Maximum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature +brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Max_Discharge_Air_Temperature_Setpoint_Limit,brick:Maximum,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Max_Frequency_Command,brick:Maximum,,,,,quantitykind:Frequency,brick:Command,,Sets the maximum permitted frequency +brick:Max_Fresh_Air_Setpoint_Limit,brick:Maximum,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Max_Limit,brick:Maximum,,,,,,brick:Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. +brick:Max_Load_Setpoint,brick:Maximum,,,,,,brick:Setpoint,Load, +brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Outside_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Max_Position_Setpoint_Limit,brick:Maximum,,,,,,brick:Setpoint_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. +brick:Max_Speed_Setpoint_Limit,brick:Maximum,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Static_Pressure_Setpoint_Limit,brick:Maximum,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Max_Supply_Air_Temperature_Setpoint_Limit,brick:Maximum,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Max_Temperature_Setpoint_Limit,brick:Maximum,,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. +brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Water_Level_Alarm,brick:Maximum,,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the maximum water level was reached +brick:Max_Water_Temperature_Setpoint,brick:Maximum,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for max water temperature +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between sections of a medium temperature hot water system +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Methane_Level_Sensor,,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air +brick:Min_Air_Flow_Setpoint_Limit,brick:Minimum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Min_Air_Temperature_Setpoint,brick:Minimum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for minimum air temperature +brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Min_Discharge_Air_Temperature_Setpoint_Limit,brick:Minimum,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Min_Frequency_Command,brick:Minimum,,,,,quantitykind:Frequency,brick:Command,, +brick:Min_Fresh_Air_Setpoint_Limit,brick:Minimum,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Min_Limit,brick:Minimum,,,,,,brick:Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. +brick:Min_Load_Setpoint,brick:Minimum,,,,,,brick:Setpoint,Load, +brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Outside_Air_Flow_Setpoint_Limit,brick:Minimum,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Min_Position_Setpoint_Limit,brick:Minimum,,,,,,brick:Setpoint_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. +brick:Min_Speed_Setpoint_Limit,brick:Minimum,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Static_Pressure_Setpoint_Limit,brick:Minimum,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Min_Supply_Air_Temperature_Setpoint_Limit,brick:Minimum,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Min_Temperature_Setpoint_Limit,brick:Minimum,,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. +brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Water_Level_Alarm,brick:Minimum,,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the minimum water level was reached +brick:Min_Water_Temperature_Setpoint,brick:Minimum,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for min water temperature +brick:Mixed_Air_Flow_Sensor,,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air +brick:Mixed_Air_Humidity_Sensor,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air +brick:Mixed_Air_Humidity_Setpoint,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air +brick:Mixed_Air_Temperature_Sensor,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air +brick:Mixed_Air_Temperature_Setpoint,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air +brick:Mode_Command,,,,,,,brick:Command,Mode,Controls the operating mode of a device or controller +brick:Mode_Status,,,,,,,brick:Status,Mode,"Indicates which mode a system, device or control loop is currently in" +brick:Motion_Sensor,,,,,,,brick:Sensor,Motion,Detects the presence of motion in some area +brick:Motor_Current_Sensor,,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor +brick:Motor_Direction_Status,,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" +brick:Motor_On_Off_Status,,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Motor_Speed_Sensor,,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, +brick:Motor_Torque_Sensor,,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" +brick:Natural_Gas_Flow_Sensor,,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas +brick:Natural_Gas_Temperature_Sensor,,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas +brick:Natural_Gas_Usage_Sensor,,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" +brick:No_Water_Alarm,,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system +brick:NO2_Level_Sensor,,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air +brick:Occupancy_Command,,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" +brick:Occupancy_Count_Sensor,,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area +brick:Occupancy_Sensor,,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area +brick:Occupancy_Status,,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied +brick:Occupied_Air_Temperature_Setpoint,,brick:Occupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when occupied +brick:Occupied_Cooling_Mode_Status,,brick:Occupied,brick:Cooling,,,,brick:Status,Mode, +brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling when occupied +brick:Occupied_Cooling_Temperature_Deadband_Setpoint,,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for cooling when occupied +brick:Occupied_Cooling_Temperature_Setpoint,,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling when occupied +brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,,brick:Occupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air cooling when occupied +brick:Occupied_Discharge_Air_Flow_Setpoint,,brick:Occupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow when occupied +brick:Occupied_Discharge_Air_Temperature_Setpoint,,brick:Occupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating when occupied +brick:Occupied_Heating_Mode_Status,,brick:Occupied,brick:Heating,,,,brick:Status,Mode, +brick:Occupied_Heating_Supply_Air_Flow_Setpoint,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating when occupied +brick:Occupied_Heating_Temperature_Deadband_Setpoint,,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for heating when occupied +brick:Occupied_Heating_Temperature_Setpoint,,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating when occupied +brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,,brick:Occupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air heating when occupied +brick:Occupied_Humidity_Setpoint,,brick:Occupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is occupied. +brick:Occupied_Load_Shed_Command,,brick:Occupied,brick:Load_Shed,,,,brick:Command,, +brick:Occupied_Mode_Status,,brick:Occupied,,,,,brick:Status,Mode,"Indicates if a system, device or control loop is in ""Occupied"" mode" +brick:Occupied_Return_Air_Temperature_Setpoint,,brick:Occupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Room_Air_Temperature_Setpoint,,brick:Occupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Supply_Air_Flow_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied +brick:Occupied_Supply_Air_Temperature_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Target_Zone_Air_Temperature_Setpoint,,brick:Occupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Off_Command,,,,,,,brick:Command,Off,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" +brick:Off_Status,,,,,,,brick:Status,Off,"Indicates if a control loop, relay or equipment is off" +brick:On_Command,,,,,,,brick:Command,On,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" +brick:On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" +brick:On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" +brick:On_Status,,,,,,,brick:Status,On,"Indicates if a control loop, relay or equipment is on" +brick:On_Timer_Sensor,,,,,,,brick:Sensor,On Timer,"Measures the duration for which a device was in an active or ""on"" state" +brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" +brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, +brick:Operating_Mode_Status,,,,,,,brick:Status,Operating Mode,"Indicates the current operating mode of a system, device or control loop" +brick:Output_Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,Output, +brick:Output_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device +brick:Outside_Air_CO_Sensor,,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air +brick:Outside_Air_CO2_Sensor,,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air +brick:Outside_Air_Dewpoint_Sensor,,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air +brick:Outside_Air_Enthalpy_Sensor,,,,brick:Outside_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air +brick:Outside_Air_Flow_Sensor,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system +brick:Outside_Air_Flow_Setpoint,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate +brick:Outside_Air_Grains_Sensor,,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air +brick:Outside_Air_Humidity_Sensor,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air +brick:Outside_Air_Humidity_Setpoint,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Outside_Air_Lockout_Temperature_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, +brick:Outside_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Outside_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Outside_Air_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air +brick:Outside_Air_Temperature_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air +brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air +brick:Outside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. +brick:Outside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. +brick:Outside_Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" +brick:Overload_Alarm,,,,,,,brick:Alarm,Overload,An alarm that can indicate when a full-load current is exceeded. +brick:Overridden_Off_Status,,,,,,,brick:Status,Overridden Off,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" +brick:Overridden_On_Status,,,,,,,brick:Status,Overridden On,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" +brick:Overridden_Status,,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden +brick:Override_Command,,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' +brick:Ozone_Level_Sensor,,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air +brick:Parameter,,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values +brick:Particulate_Matter_Sensor,,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air +brick:Peak_Demand_Sensor,brick:Peak,,,,,,brick:Demand_Sensor,,The peak power consumed by a process over some period of time +brick:Photovoltaic_Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Photovoltaic Output,Senses the amperes of electrical current produced as output by a photovoltaic device +brick:PID_Parameter,,,,,,,brick:Parameter,PID, +brick:Piezoelectric_Sensor,,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:PM1_Level_Sensor,,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron +brick:PM10_Level_Sensor,,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,,brick:PM10,,,brick:Sensor,,Detects matter of size 10 microns +brick:PM2.5_Level_Sensor,,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns +brick:PM2.5_Sensor,,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns +brick:Position_Command,,,,,,,brick:Command,Position,Controls or reports the position of some object +brick:Position_Limit,,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. +brick:Position_Sensor,,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion +brick:Power_Alarm,,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. +brick:Power_Factor_Sensor,,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." +brick:Power_Loss_Alarm,,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. +brick:Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed +brick:Pre_Filter_Status,,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced +brick:Preheat_Command,,,,,,,brick:Command,Preheat,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer +brick:Preheat_Demand_Setpoint,,,,,,,brick:Demand_Setpoint,Preheat,Sets the rate required for preheat +brick:Preheat_Discharge_Air_Temperature_Sensor,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of discharge air before heating is applied +brick:Preheat_Supply_Air_Temperature_Sensor,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of supply air before it is heated +brick:Pressure_Alarm,,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. +brick:Pressure_Sensor,,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area +brick:Pressure_Setpoint,,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure +brick:Pressure_Status,,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds +brick:Proportional_Band_Parameter,,,,,,,brick:Proportional_Band_Parameter,, +brick:Proportional_Gain_Parameter,,,,,,,brick:Proportional_Gain_Parameter,, +brick:Pump_Command,,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) +brick:Pump_On_Off_Status,,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Pump_Status,,,brick:Pump,,,,brick:Status,,Status of a pump +brick:PV_Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,PV Output,See Photovoltaic_Current_Output_Sensor +brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. +brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. +brick:Radon_Concentration_Sensor,,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon +brick:Rain_Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame +brick:Rain_Level_Sensor,,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen +brick:Rated_Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed +brick:Reactive_Energy_Sensor,,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power +brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" +brick:Refrigerant_Level_Sensor,,,,brick:Refrigerant,,,brick:Sensor,Level, +brick:Reheat_Command,,,,,,,brick:Command,Reheat,"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Relative_Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature +brick:Relay_Command,,,brick:Relay,,,,brick:Command,,Commands to switch the relay +brick:Remotely_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Remotely, +brick:Reset_Command,,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" +brick:Reset_Setpoint,,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies +brick:Return_Air_CO_Sensor,,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air +brick:Return_Air_CO2_Sensor,,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air +brick:Return_Air_CO2_Setpoint,,,,brick:Return_Air,,,brick:Setpoint,CO2,Sets some property of CO2 in Return Air +brick:Return_Air_Dewpoint_Sensor,,,,brick:Return_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air +brick:Return_Air_Differential_Pressure_Sensor,,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side +brick:Return_Air_Differential_Pressure_Setpoint,,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit +brick:Return_Air_Enthalpy_Sensor,,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air +brick:Return_Air_Flow_Sensor,,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air +brick:Return_Air_Grains_Sensor,,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air +brick:Return_Air_Humidity_Sensor,,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air +brick:Return_Air_Humidity_Setpoint,,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air +brick:Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. +brick:Return_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Return_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Return_Air_Temperature_Sensor,,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air +brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" +brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, +brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air +brick:Run_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Run, +brick:Run_Request_Status,,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment +brick:Run_Status,,,,,,,brick:Status,Run, +brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" +brick:Sash_Position_Sensor,,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule +brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). +brick:Sensor_Failure_Alarm,,,,,,,brick:Failure_Alarm,Sensor, +brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set +brick:Short_Cycle_Alarm,,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Smoke_Alarm,,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. +brick:Smoke_Detection_Alarm,,,,,,,brick:Alarm,Smoke Detection, +brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil +brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun +brick:Solar_Irradiance_Sensor,,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems +brick:Solar_Zenith_Angle_Sensor,,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun +brick:Speed_Command,,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. +brick:Speed_Mode_Status,,,,,,quantitykind:Speed,brick:Status,Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, +brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement +brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed +brick:Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. +brick:Stage_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Stage,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in +brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Glycool Unit,Indicates the on/off status of a standby glycool unit +brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, +brick:Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Standby, +brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, +brick:Standby_Unit_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Unit,Indicates the on/off status of a standby unit +brick:Start_Stop_Command,,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence +brick:Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) +brick:Static_Pressure_Deadband_Setpoint,,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure +brick:Static_Pressure_Integral_Time_Parameter,,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Static_Pressure_Proportional_Band_Parameter,,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Static_Pressure_Sensor,,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work +brick:Static_Pressure_Setpoint,,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure +brick:Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Static_Pressure_Step_Parameter,,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Status,,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" +brick:Steam_On_Off_Command,,,,brick:Steam,,brick:EnumerationKind-On_Off,brick:Command,, +brick:Steam_Usage_Sensor,,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" +brick:Step_Parameter,,,,,,,brick:Step_Parameter,, +brick:Supply_Air_Dewpoint_Sensor,,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, +brick:Supply_Air_Differential_Pressure_Sensor,,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building +brick:Supply_Air_Differential_Pressure_Setpoint,,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit +brick:Supply_Air_Duct_Pressure_Status,,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds +brick:Supply_Air_Flow_Demand_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process +brick:Supply_Air_Flow_High_Reset_Setpoint,brick:High,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_Low_Reset_Setpoint,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_Sensor,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air +brick:Supply_Air_Flow_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate +brick:Supply_Air_Humidity_Sensor,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air +brick:Supply_Air_Humidity_Setpoint,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air +brick:Supply_Air_Integral_Gain_Parameter,,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, +brick:Supply_Air_Proportional_Gain_Parameter,,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, +brick:Supply_Air_Smoke_Detection_Alarm,,,,brick:Supply_Air,,,brick:Alarm,Smoke Detection, +brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air +brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Static_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system +brick:Supply_Air_Static_Pressure_Setpoint,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air +brick:Supply_Air_Static_Pressure_Step_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. +brick:Supply_Air_Temperature_Cooling_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Supply_Air_Temperature_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air +brick:Supply_Air_Temperature_Heating_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Supply_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Supply_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Supply_Air_Temperature_Sensor,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air +brick:Supply_Air_Temperature_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air +brick:Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Supply_Air_Temperature_Step_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Supply_Air_Velocity_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Switch_Status,,,brick:Switch,,,,brick:Status,,Status of a switch +brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a system +brick:System_Shutdown_Status,,,brick:System,,,,brick:Status,Shutdown,Indicates if a system has been shutdown +brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system +brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, +brick:Temperature_Adjust_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Adjust,Measures user-provided adjustment of temperature +brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. +brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a temperature alarm. +brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature +brick:Temperature_Differential_Reset_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_High_Reset_Setpoint,brick:High,,,,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_Low_Reset_Setpoint,brick:Low,,,,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_Parameter,,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points +brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold +brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature +brick:Temperature_Step_Parameter,,,,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Temperature_Tolerance_Parameter,,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. +brick:Temporary_Occupancy_Status,,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period +brick:Thermal_Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Thermostat_Status,,,brick:Thermostat,,,,brick:Status,,Status of a thermostat +brick:Time_Parameter,,,,,,,brick:Parameter,Time, +brick:Time_Setpoint,,,,,,,brick:Setpoint,Time, +brick:Tint_Command,,,,,,,brick:Command,Tint,The target level of window tint. +brick:Tint_Status,,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." +brick:Tolerance_Parameter,,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. +brick:Torque_Sensor,,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" +brick:TVOC_Level_Sensor,,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the level of all VOCs in air +brick:TVOC_Sensor,,,,brick:VOC,,,brick:Sensor,, +brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum +brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure +brick:Underfloor_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air +brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device +brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied +brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied +brick:Unoccupied_Cooling_Mode_Status,,brick:Unoccupied,brick:Cooling,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" +brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Cooling_Temperature_Setpoint,,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for cooling within a specific zone +brick:Unoccupied_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Discharge_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Mode_Status,,brick:Unoccupied,brick:Heating,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in an unoccupied heating mode" +brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Heating_Temperature_Setpoint,,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for heating within a specific zone +brick:Unoccupied_Humidity_Setpoint,,brick:Unoccupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is unoccupied. +brick:Unoccupied_Load_Shed_Command,,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,, +brick:Unoccupied_Mode_Status,,brick:Unoccupied,,,,,brick:Status,Mode, +brick:Unoccupied_Return_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Room_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Flow_Setpoint,,brick:Unoccupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Usage_Sensor,,,,,,,brick:Sensor,Usage,"Measures the amount of some substance that is consumed or used, over some period of time" +brick:Valve_Command,,,brick:Valve,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) +brick:Valve_Position_Alarm,,,brick:Valve,,,,brick:Alarm,Position,An alarm that indicates that the valve position is not in a normal state. +brick:Valve_Position_Command,,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve +brick:Valve_Position_Sensor,,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open +brick:Valve_Status,,,brick:Valve,,,,brick:Status,,The current status of the valve. +brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure +brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure +brick:Vent_Operating_Mode_Status,,,,,,,brick:Status,Vent Operating Mode,Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:VFD_Enable_Command,,,brick:VFD,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a variable frequency drive +brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. +brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system +brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer +brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object +brick:Warm_Cool_Adjust_Sensor,,,,,,,brick:Sensor,Warm Cool Adjust,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Waste_Amount_Sensor,,,,,,,brick:Sensor,Waste Amount,A metric used for measuring the quantity of waste generated in a building. +brick:Water_Alarm,,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" +brick:Water_Differential_Pressure_Sensor,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. +brick:Water_Differential_Pressure_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit +brick:Water_Differential_Temperature_Sensor,,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit +brick:Water_Differential_Temperature_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit +brick:Water_Flow_Sensor,,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water +brick:Water_Flow_Setpoint,,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water +brick:Water_Level_Alarm,,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin +brick:Water_Level_Sensor,,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container +brick:Water_Loss_Alarm,,,,brick:Water,,,brick:Loss_Alarm,,An alarm that indicates a loss of water e.g. during transport +brick:Water_Pressure_Sensor,,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. +brick:Water_Pressure_Setpoint,,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, +brick:Water_Temperature_Alarm,,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. +brick:Water_Temperature_Sensor,,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water +brick:Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water +brick:Water_Usage_Sensor,,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" +brick:Wind_Direction_Sensor,,,,,,,brick:Sensor,Wind Direction,Measures the direction of wind in degrees relative to North +brick:Wind_Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,Wind,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Zone_Air_Conditioning_Mode_Status,,,,brick:Zone_Air,,,brick:Status,Conditioning Mode,Indicates the mode of AC for a zone +brick:Zone_Air_Dewpoint_Sensor,,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air +brick:Zone_Air_Humidity_Sensor,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air +brick:Zone_Air_Humidity_Setpoint,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air +brick:Zone_Air_Temperature_Sensor,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone +brick:Zone_CO2_Level_Sensor,,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone +brick:Zone_Occupied_Load_Shed_Command,,brick:Occupied,brick:Load_Shed,,,,brick:Command,Zone, +brick:Zone_Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Zone Standby, +brick:Zone_Unoccupied_Load_Shed_Command,,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,Zone, From 097ff83267aa115db924066d54a18b6507455adb Mon Sep 17 00:00:00 2001 From: ektrah Date: Tue, 28 Oct 2025 18:41:39 +0100 Subject: [PATCH 12/31] Define all point attributes [no ci] --- bricksrc/points.csv | 98 ++++++++++++++++++++++----------------------- 1 file changed, 49 insertions(+), 49 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 0834d75c..ed17b038 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -30,7 +30,7 @@ brick:Air_Velocity_Pressure_Sensor,,,,brick:Air,,quantitykind:DynamicPressure,br brick:Air_Wet_Bulb_Temperature_Sensor,,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, brick:Alarm,,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action brick:Alarm_Delay_Parameter,,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met -brick:Alarm_Sensitivity_Parameter,,,,,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate an alarm. +brick:Alarm_Sensitivity_Parameter,,,,,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate an alarm. brick:Ammonia_Sensor,,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air brick:Angle_Sensor,,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon brick:Automatic_Mode_Command,,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" @@ -43,7 +43,7 @@ brick:Average_Supply_Air_Flow_Sensor,brick:Average,,,brick:Supply_Air,,quantityk brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" brick:Battery_Voltage_Sensor,,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery brick:Boiler_Command,,,brick:Boiler,,,,brick:Command,,A command to control a boiler -brick:Box_Mode_Command,,,,,,,brick:Command,Box Mode, +brick:Box_Mode_Command,,,,,,brick:EnumerationKind-Mode,brick:Command,Box, brick:Building_Air_Humidity_Setpoint,,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building brick:Building_Air_Static_Pressure_Sensor,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building brick:Building_Air_Static_Pressure_Setpoint,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building @@ -76,7 +76,7 @@ brick:CO_Differential_Sensor,,,,brick:CO,brick:Differential,,brick:Sensor,, brick:CO_Level_Sensor,,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO brick:CO_Sensor,,,,brick:CO,,,brick:Sensor,,Measures properties of CO brick:CO2_Alarm,,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. -brick:CO2_Alarm_Sensitivity_Parameter,,,,brick:CO2,,,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a CO2 alarm. +brick:CO2_Alarm_Sensitivity_Parameter,,,,brick:CO2,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a CO2 alarm. brick:CO2_Differential_Sensor,,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air brick:CO2_Level_Sensor,,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air brick:CO2_Sensor,,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air @@ -101,7 +101,7 @@ brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick: brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Cooling_Enable_Command,,,brick:Cooling,,,brick:EnumerationKind-Enable,brick:Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." -brick:Cooling_Mode_Status,,,brick:Cooling,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in a cooling mode" +brick:Cooling_Mode_Status,,,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" brick:Cooling_Start_Stop_Status,,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for cooling @@ -176,7 +176,7 @@ brick:Discharge_Air_Humidity_Sensor,,,,brick:Discharge_Air,,quantitykind:Relativ brick:Discharge_Air_Humidity_Setpoint,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air brick:Discharge_Air_Integral_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, brick:Discharge_Air_Proportional_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, -brick:Discharge_Air_Smoke_Detection_Alarm,,,,brick:Discharge_Air,,,brick:Alarm,Smoke Detection, +brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Smoke_Detection,brick:Discharge_Air,,,brick:Alarm,, brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, @@ -220,8 +220,8 @@ brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Emb brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, brick:Emergency_Alarm,,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems -brick:Emergency_Generator_Alarm,,,,,,,brick:Alarm,Emergency Generator,An alarm that indicates off-normal conditions associated with an emergency generator -brick:Emergency_Generator_Status,,,,,,,brick:Status,Emergency Generator,Indicates if an emergency generator is active +brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High,,brick:Emergency_Power_Off_System,,,quantitykind:Temperature,brick:Status,Activated By, brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, @@ -243,9 +243,9 @@ brick:Entering_Chilled_Water_Temperature_Setpoint,,,,brick:Entering_Chilled_Wate brick:Entering_Condenser_Water_Flow_Sensor,,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water brick:Entering_Condenser_Water_Temperature_Sensor,,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water brick:Entering_Condenser_Water_Temperature_Setpoint,,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water -brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering, -brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering, -brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering,Measures the temperature of high-temperature hot water enteringed to a hot water system +brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Entering_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water enteringed to a hot water system brick:Entering_Hot_Water_Flow_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water brick:Entering_Hot_Water_Flow_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, @@ -253,11 +253,11 @@ brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:En brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, brick:Entering_Hot_Water_Temperature_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system brick:Entering_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water -brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Entering, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,Entering, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Entering, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Entering,Measures the temperature of medium-temperature hot water entering a hot water system +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water entering a hot water system brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, @@ -321,7 +321,7 @@ brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressu brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger,,,brick:EnumerationKind-Enable,brick:Status,System,Indicates if the heat exchanger system has been enabled +brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if the heat exchanger system has been enabled brick:Heat_Sink_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton @@ -331,7 +331,7 @@ brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick: brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Heating_Enable_Command,,,brick:Heating,,,brick:EnumerationKind-Enable,brick:Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." -brick:Heating_Mode_Status,,,brick:Heating,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in a heating mode" +brick:Heating_Mode_Status,,,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" brick:Heating_Start_Stop_Status,,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for heating @@ -377,7 +377,7 @@ brick:Humidity_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Par brick:Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air brick:Humidity_Setpoint,,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity brick:Humidity_Tolerance_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. -brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,,brick:Tank,brick:Ice,,quantitykind:Temperature,brick:Sensor,Leaving Water,Measures the temperature of water leaving an ice tank +brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,,brick:Ice_Tank,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving an ice tank brick:Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" brick:Illuminance_Setpoint,,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. brick:Imbalance_Sensor,,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system @@ -398,9 +398,9 @@ brick:Leaving_Chilled_Water_Temperature_Setpoint,,,,brick:Leaving_Chilled_Water, brick:Leaving_Condenser_Water_Flow_Sensor,,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water brick:Leaving_Condenser_Water_Temperature_Sensor,,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water brick:Leaving_Condenser_Water_Temperature_Setpoint,,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water -brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of domestic water supplied by a hot water system -brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving,Sets temperature of leavinging part of domestic hot water -brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of high-temperature hot water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of domestic water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leavinging part of domestic hot water +brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Leaving_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water supplied by a hot water system brick:Leaving_Hot_Water_Flow_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water brick:Leaving_Hot_Water_Flow_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, @@ -408,11 +408,11 @@ brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Lea brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, brick:Leaving_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system brick:Leaving_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,Leaving, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,Leaving, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,Leaving, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,Leaving,Measures the temperature of medium-temperature hot water supplied by a hot water system +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water supplied by a hot water system brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, @@ -459,13 +459,13 @@ brick:Low_Supply_Air_Temperature_Alarm,brick:Low,,,brick:Supply_Air,,quantitykin brick:Low_Temperature_Alarm,brick:Low,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates low temperature. brick:Low_Temperature_Alarm_Parameter,brick:Low,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm brick:Low_Voltage_Alarm,brick:Low,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is lower than its normal state. -brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,Lowest,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,brick:Lowest,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time brick:Luminance_Alarm,,,,,,quantitykind:Luminance,brick:Alarm,, brick:Luminance_Command,,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system brick:Luminance_Sensor,,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance -brick:Maintenance_Mode_Command,,,,,,,brick:Command,Maintenance Mode,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" -brick:Maintenance_Required_Alarm,,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Maintenance_Mode_Command,,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" +brick:Maintenance_Required_Alarm,,,,,,brick:EnumerationKind-Maintenance_Required,brick:Alarm,,An alarm that indicates that repair/maintenance is required on an associated device or equipment brick:Manual_Auto_Status,,,,,,,brick:Status,Manual Auto,Indicates if a system is under manual or automatic operation brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. brick:Max_Air_Temperature_Setpoint,brick:Maximum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature @@ -540,8 +540,8 @@ brick:Mixed_Air_Humidity_Sensor,,,,brick:Mixed_Air,,quantitykind:RelativeHumidit brick:Mixed_Air_Humidity_Setpoint,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air brick:Mixed_Air_Temperature_Sensor,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air brick:Mixed_Air_Temperature_Setpoint,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air -brick:Mode_Command,,,,,,,brick:Command,Mode,Controls the operating mode of a device or controller -brick:Mode_Status,,,,,,,brick:Status,Mode,"Indicates which mode a system, device or control loop is currently in" +brick:Mode_Command,,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the operating mode of a device or controller +brick:Mode_Status,,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" brick:Motion_Sensor,,,,,,,brick:Sensor,Motion,Detects the presence of motion in some area brick:Motor_Current_Sensor,,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor brick:Motor_Direction_Status,,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" @@ -559,7 +559,7 @@ brick:Occupancy_Sensor,,,,,,,brick:Sensor,Occupancy,Detects occupancy of some sp brick:Occupancy_Status,,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied brick:Occupied_Air_Temperature_Setpoint,,brick:Occupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,, brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when occupied -brick:Occupied_Cooling_Mode_Status,,brick:Occupied,brick:Cooling,,,,brick:Status,Mode, +brick:Occupied_Cooling_Mode_Status,,brick:Occupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,, brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling when occupied brick:Occupied_Cooling_Temperature_Deadband_Setpoint,,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for cooling when occupied brick:Occupied_Cooling_Temperature_Setpoint,,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling when occupied @@ -567,14 +567,14 @@ brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,,brick:Occupied,brick:Cooli brick:Occupied_Discharge_Air_Flow_Setpoint,,brick:Occupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow when occupied brick:Occupied_Discharge_Air_Temperature_Setpoint,,brick:Occupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating when occupied -brick:Occupied_Heating_Mode_Status,,brick:Occupied,brick:Heating,,,,brick:Status,Mode, +brick:Occupied_Heating_Mode_Status,,brick:Occupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,, brick:Occupied_Heating_Supply_Air_Flow_Setpoint,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating when occupied brick:Occupied_Heating_Temperature_Deadband_Setpoint,,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for heating when occupied brick:Occupied_Heating_Temperature_Setpoint,,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating when occupied brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,,brick:Occupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air heating when occupied brick:Occupied_Humidity_Setpoint,,brick:Occupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is occupied. brick:Occupied_Load_Shed_Command,,brick:Occupied,brick:Load_Shed,,,,brick:Command,, -brick:Occupied_Mode_Status,,brick:Occupied,,,,,brick:Status,Mode,"Indicates if a system, device or control loop is in ""Occupied"" mode" +brick:Occupied_Mode_Status,,brick:Occupied,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates if a system, device or control loop is in ""Occupied"" mode" brick:Occupied_Return_Air_Temperature_Setpoint,,brick:Occupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Occupied_Room_Air_Temperature_Setpoint,,brick:Occupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Occupied_Supply_Air_Flow_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied @@ -590,7 +590,7 @@ brick:On_Timer_Sensor,,,,,,,brick:Sensor,On Timer,"Measures the duration for whi brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, -brick:Operating_Mode_Status,,,,,,,brick:Status,Operating Mode,"Indicates the current operating mode of a system, device or control loop" +brick:Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" brick:Output_Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,Output, brick:Output_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device brick:Outside_Air_CO_Sensor,,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air @@ -640,10 +640,10 @@ brick:Power_Factor_Sensor,,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors m brick:Power_Loss_Alarm,,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. brick:Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed brick:Pre_Filter_Status,,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced -brick:Preheat_Command,,,,,,,brick:Command,Preheat,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer -brick:Preheat_Demand_Setpoint,,,,,,,brick:Demand_Setpoint,Preheat,Sets the rate required for preheat -brick:Preheat_Discharge_Air_Temperature_Sensor,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of discharge air before heating is applied -brick:Preheat_Supply_Air_Temperature_Sensor,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,Preheat,Measures the temperature of supply air before it is heated +brick:Preheat_Command,,,brick:Preheat,,,,brick:Command,,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer +brick:Preheat_Demand_Setpoint,,,brick:Preheat,,,,brick:Demand_Setpoint,,Sets the rate required for preheat +brick:Preheat_Discharge_Air_Temperature_Sensor,,,brick:Preheat,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air before heating is applied +brick:Preheat_Supply_Air_Temperature_Sensor,,,brick:Preheat,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air before it is heated brick:Pressure_Alarm,,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. brick:Pressure_Sensor,,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area brick:Pressure_Setpoint,,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure @@ -698,13 +698,13 @@ brick:Sensor_Failure_Alarm,,,,,,,brick:Failure_Alarm,Sensor, brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set brick:Short_Cycle_Alarm,,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle brick:Smoke_Alarm,,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. -brick:Smoke_Detection_Alarm,,,,,,,brick:Alarm,Smoke Detection, +brick:Smoke_Detection_Alarm,,,brick:Smoke_Detection,,,,brick:Alarm,, brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun brick:Solar_Irradiance_Sensor,,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems brick:Solar_Zenith_Angle_Sensor,,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun brick:Speed_Command,,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. -brick:Speed_Mode_Status,,,,,,quantitykind:Speed,brick:Status,Mode,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Mode_Status,,,,,,brick:EnumerationKind-Speed_Mode,brick:Status,,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed @@ -744,7 +744,7 @@ brick:Supply_Air_Humidity_Sensor,,,,brick:Supply_Air,,quantitykind:RelativeHumid brick:Supply_Air_Humidity_Setpoint,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air brick:Supply_Air_Integral_Gain_Parameter,,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, brick:Supply_Air_Proportional_Gain_Parameter,,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, -brick:Supply_Air_Smoke_Detection_Alarm,,,,brick:Supply_Air,,,brick:Alarm,Smoke Detection, +brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Smoke_Detection,brick:Supply_Air,,,brick:Alarm,, brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, @@ -766,12 +766,12 @@ brick:Supply_Air_Temperature_Step_Parameter,,,,brick:Supply_Air,,quantitykind:Te brick:Supply_Air_Velocity_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Switch_Status,,,brick:Switch,,,,brick:Status,,Status of a switch brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a system -brick:System_Shutdown_Status,,,brick:System,,,,brick:Status,Shutdown,Indicates if a system has been shutdown +brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, brick:Temperature_Adjust_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Adjust,Measures user-provided adjustment of temperature brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. -brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Parameter,Alarm Sensitivity,A parameter indicates the sensitivity to activate a temperature alarm. +brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature brick:Temperature_Differential_Reset_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, brick:Temperature_High_Reset_Setpoint,brick:High,,,,,quantitykind:Temperature,brick:Reset_Setpoint,, @@ -799,7 +799,7 @@ brick:Underfloor_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,b brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied -brick:Unoccupied_Cooling_Mode_Status,,brick:Unoccupied,brick:Cooling,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" +brick:Unoccupied_Cooling_Mode_Status,,brick:Unoccupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,, brick:Unoccupied_Cooling_Temperature_Setpoint,,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,, @@ -807,14 +807,14 @@ brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,brick:C brick:Unoccupied_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Unoccupied_Discharge_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Unoccupied_Heating_Mode_Status,,brick:Unoccupied,brick:Heating,,,,brick:Status,Mode,"Indicates whether a system, device or control loop is in an unoccupied heating mode" +brick:Unoccupied_Heating_Mode_Status,,brick:Unoccupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied heating mode" brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,, brick:Unoccupied_Heating_Temperature_Setpoint,,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,, brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for heating within a specific zone brick:Unoccupied_Humidity_Setpoint,,brick:Unoccupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is unoccupied. brick:Unoccupied_Load_Shed_Command,,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,, -brick:Unoccupied_Mode_Status,,brick:Unoccupied,,,,,brick:Status,Mode, +brick:Unoccupied_Mode_Status,,brick:Unoccupied,,,,brick:EnumerationKind-Mode,brick:Status,, brick:Unoccupied_Return_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Unoccupied_Room_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Unoccupied_Supply_Air_Flow_Setpoint,,brick:Unoccupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, @@ -828,7 +828,7 @@ brick:Valve_Position_Sensor,,,brick:Valve,,,,brick:Sensor,Position,Measures the brick:Valve_Status,,,brick:Valve,,,,brick:Status,,The current status of the valve. brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,,brick:Status,Vent Operating Mode,Indicates the current operating mode of a vent +brick:Vent_Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,Vent,Indicates the current operating mode of a vent brick:Ventilation_Air_Flow_Ratio_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. brick:VFD_Enable_Command,,,brick:VFD,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. @@ -856,7 +856,7 @@ brick:Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick: brick:Water_Usage_Sensor,,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" brick:Wind_Direction_Sensor,,,,,,,brick:Sensor,Wind Direction,Measures the direction of wind in degrees relative to North brick:Wind_Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,Wind,"Measured speed of wind, caused by air moving from high to low pressure" -brick:Zone_Air_Conditioning_Mode_Status,,,,brick:Zone_Air,,,brick:Status,Conditioning Mode,Indicates the mode of AC for a zone +brick:Zone_Air_Conditioning_Mode_Status,,,,brick:Zone_Air,,brick:EnumerationKind-Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone brick:Zone_Air_Dewpoint_Sensor,,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air brick:Zone_Air_Humidity_Sensor,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air brick:Zone_Air_Humidity_Setpoint,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air From 8d398730a5f64d86ecadf63715d335acc3bc0ebc Mon Sep 17 00:00:00 2001 From: ektrah Date: Tue, 28 Oct 2025 18:59:00 +0100 Subject: [PATCH 13/31] Define all point attributes [no ci] --- bricksrc/points.csv | 32 ++++++++++++++++---------------- 1 file changed, 16 insertions(+), 16 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index ed17b038..a0ea50ce 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -2,7 +2,7 @@ brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity brick:Acceleration_Time_Setpoint,,,,,,,brick:Setpoint,Acceleration Time, brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" -brick:Adjust_Sensor,,,,,,,brick:Sensor,Adjust,Measures user-provided adjustment of some value +brick:Adjust_Sensor,,,,,,,brick:Adjust_Sensor,,Measures user-provided adjustment of some value brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, brick:Air_Differential_Pressure_Sensor,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air brick:Air_Differential_Pressure_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit @@ -29,7 +29,7 @@ brick:Air_Temperature_Step_Parameter,,,,brick:Air,,quantitykind:Temperature,bric brick:Air_Velocity_Pressure_Sensor,,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. brick:Air_Wet_Bulb_Temperature_Sensor,,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, brick:Alarm,,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action -brick:Alarm_Delay_Parameter,,,,,,,brick:Parameter,Alarm Delay,A parameter determining how long to delay an alarm after sufficient conditions have been met +brick:Alarm_Delay_Parameter,,,,,,,brick:Alarm_Delay_Parameter,,A parameter determining how long to delay an alarm after sufficient conditions have been met brick:Alarm_Sensitivity_Parameter,,,,,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate an alarm. brick:Ammonia_Sensor,,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air brick:Angle_Sensor,,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon @@ -43,7 +43,7 @@ brick:Average_Supply_Air_Flow_Sensor,brick:Average,,,brick:Supply_Air,,quantityk brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" brick:Battery_Voltage_Sensor,,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery brick:Boiler_Command,,,brick:Boiler,,,,brick:Command,,A command to control a boiler -brick:Box_Mode_Command,,,,,,brick:EnumerationKind-Mode,brick:Command,Box, +brick:Box_Mode_Command,,,,,,brick:EnumerationKind-Box_Mode,brick:Command,, brick:Building_Air_Humidity_Setpoint,,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building brick:Building_Air_Static_Pressure_Sensor,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building brick:Building_Air_Static_Pressure_Setpoint,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building @@ -131,11 +131,11 @@ brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidifi brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. brick:Deionized_Water_Conductivity_Sensor,,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water brick:Deionized_Water_Level_Sensor,,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container -brick:Delay_Parameter,,,,,,,brick:Parameter,Delay,A parameter determining how long to delay a subsequent action to take place after a received signal +brick:Delay_Parameter,,,,,,,brick:Delay_Parameter,,A parameter determining how long to delay a subsequent action to take place after a received signal brick:Demand_Sensor,,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Demand_Setpoint,,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process -brick:Derivative_Gain_Parameter,,,,,,,brick:Parameter,Derivative Gain, -brick:Derivative_Time_Parameter,,,,,,,brick:Parameter,Derivative Time, +brick:Derivative_Gain_Parameter,,,,,,,brick:Derivative_Gain_Parameter,, +brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air @@ -174,7 +174,7 @@ brick:Discharge_Air_Flow_Sensor,,,,brick:Discharge_Air,,quantitykind:VolumeFlowR brick:Discharge_Air_Flow_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow brick:Discharge_Air_Humidity_Sensor,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air brick:Discharge_Air_Humidity_Setpoint,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air -brick:Discharge_Air_Integral_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Parameter,Integral Gain, +brick:Discharge_Air_Integral_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Integral_Gain_Parameter,, brick:Discharge_Air_Proportional_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Smoke_Detection,brick:Discharge_Air,,,brick:Alarm,, brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air @@ -312,7 +312,7 @@ brick:Freeze_Status,,,,,,,brick:Status,Freeze,Indicates if a substance contained brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency -brick:Fresh_Air_Setpoint_Limit,,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood brick:Gain_Parameter,,,,,,,brick:Parameter,Gain, @@ -384,7 +384,7 @@ brick:Imbalance_Sensor,,,,,,,brick:Sensor,Imbalance,A sensor which measures diff brick:Inside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. brick:Intake_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Intake,Measures air at the interface between the building and the outside -brick:Integral_Gain_Parameter,,,,,,,brick:Parameter,Integral Gain, +brick:Integral_Gain_Parameter,,,,,,,brick:Integral_Gain_Parameter,, brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, brick:Last_Fault_Code_Status,,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation @@ -431,7 +431,7 @@ brick:Lighting_Correlated_Color_Temperature_Command,,,brick:Lighting,,,quantityk brick:Lighting_Correlated_Color_Temperature_Sensor,,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. brick:Lighting_Level_Command,,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. brick:Limit,,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point -brick:Liquid_Detection_Alarm,,,,brick:Liquid,,,brick:Alarm,Detection, +brick:Liquid_Detection_Alarm,,,brick:Liquid_Detection,,,,brick:Alarm,, brick:Load_Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load brick:Load_Parameter,,,,,,,brick:Parameter,Load, brick:Load_Setpoint,,,,,,,brick:Setpoint,Load, @@ -466,7 +466,7 @@ brick:Luminance_Sensor,,,,,,quantitykind:Luminance,brick:Sensor,,Measures the lu brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance brick:Maintenance_Mode_Command,,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" brick:Maintenance_Required_Alarm,,,,,,brick:EnumerationKind-Maintenance_Required,brick:Alarm,,An alarm that indicates that repair/maintenance is required on an associated device or equipment -brick:Manual_Auto_Status,,,,,,,brick:Status,Manual Auto,Indicates if a system is under manual or automatic operation +brick:Manual_Auto_Status,,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. brick:Max_Air_Temperature_Setpoint,brick:Maximum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. @@ -475,7 +475,7 @@ brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Cooling,br brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. brick:Max_Discharge_Air_Temperature_Setpoint_Limit,brick:Maximum,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. brick:Max_Frequency_Command,brick:Maximum,,,,,quantitykind:Frequency,brick:Command,,Sets the maximum permitted frequency -brick:Max_Fresh_Air_Setpoint_Limit,brick:Maximum,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Fresh_Air_Setpoint_Limit,brick:Maximum,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. @@ -512,7 +512,7 @@ brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Cooling,br brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. brick:Min_Discharge_Air_Temperature_Setpoint_Limit,brick:Minimum,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. brick:Min_Frequency_Command,brick:Minimum,,,,,quantitykind:Frequency,brick:Command,, -brick:Min_Fresh_Air_Setpoint_Limit,brick:Minimum,,,brick:Air,,,brick:Setpoint_Limit,Fresh,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Fresh_Air_Setpoint_Limit,brick:Minimum,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. @@ -742,7 +742,7 @@ brick:Supply_Air_Flow_Sensor,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,br brick:Supply_Air_Flow_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate brick:Supply_Air_Humidity_Sensor,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air brick:Supply_Air_Humidity_Setpoint,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air -brick:Supply_Air_Integral_Gain_Parameter,,,,brick:Supply_Air,,,brick:Parameter,Integral Gain, +brick:Supply_Air_Integral_Gain_Parameter,,,,brick:Supply_Air,,,brick:Integral_Gain_Parameter,, brick:Supply_Air_Proportional_Gain_Parameter,,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Smoke_Detection,brick:Supply_Air,,,brick:Alarm,, brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air @@ -769,7 +769,7 @@ brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick: brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, -brick:Temperature_Adjust_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Adjust,Measures user-provided adjustment of temperature +brick:Temperature_Adjust_Sensor,,,,,,quantitykind:Temperature,brick:Adjust_Sensor,,Measures user-provided adjustment of temperature brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature @@ -835,7 +835,7 @@ brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicat brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object -brick:Warm_Cool_Adjust_Sensor,,,,,,,brick:Sensor,Warm Cool Adjust,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warm_Cool_Adjust_Sensor,,,,,,,brick:Adjust_Sensor,Warm Cool,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' brick:Waste_Amount_Sensor,,,,,,,brick:Sensor,Waste Amount,A metric used for measuring the quantity of waste generated in a building. brick:Water_Alarm,,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" From cc41290b945c7c7e27749b2c91d87fa4baaabcaf Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 01:16:21 +0100 Subject: [PATCH 14/31] Define all point attributes [no ci] --- bricksrc/points.csv | 130 ++++++++++++++++++++++---------------------- 1 file changed, 65 insertions(+), 65 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index a0ea50ce..69af4721 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,8 +1,8 @@ @id,brick:isAggregated,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity -brick:Acceleration_Time_Setpoint,,,,,,,brick:Setpoint,Acceleration Time, +brick:Acceleration_Time_Setpoint,,,,,,,,,(deprecated) brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" -brick:Adjust_Sensor,,,,,,,brick:Adjust_Sensor,,Measures user-provided adjustment of some value +brick:Adjust_Sensor,,,,,,,,,(deprecated) brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, brick:Air_Differential_Pressure_Sensor,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air brick:Air_Differential_Pressure_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit @@ -43,13 +43,13 @@ brick:Average_Supply_Air_Flow_Sensor,brick:Average,,,brick:Supply_Air,,quantityk brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" brick:Battery_Voltage_Sensor,,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery brick:Boiler_Command,,,brick:Boiler,,,,brick:Command,,A command to control a boiler -brick:Box_Mode_Command,,,,,,brick:EnumerationKind-Box_Mode,brick:Command,, +brick:Box_Mode_Command,,,,,,,,,(deprecated) brick:Building_Air_Humidity_Setpoint,,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building brick:Building_Air_Static_Pressure_Sensor,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building brick:Building_Air_Static_Pressure_Setpoint,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building brick:Bypass_Air_Flow_Sensor,,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air brick:Bypass_Air_Humidity_Setpoint,,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air -brick:Bypass_Command,,,,,,,brick:Command,Bypass, +brick:Bypass_Command,,,,,,,,,(deprecated) brick:Bypass_Water_Flow_Sensor,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water brick:Bypass_Water_Flow_Setpoint,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water brick:Capacity_Sensor,,,,,,quantitykind:Capacity,brick:Sensor,, @@ -71,7 +71,7 @@ brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykin brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the chilled water system brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water -brick:Close_Limit,,,,,,,brick:Limit,Close,A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. +brick:Close_Limit,,,,,,,,,(deprecated) brick:CO_Differential_Sensor,,,,brick:CO,brick:Differential,,brick:Sensor,, brick:CO_Level_Sensor,,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO brick:CO_Sensor,,,,brick:CO,,,brick:Sensor,,Measures properties of CO @@ -92,7 +92,7 @@ brick:Condenser_Water_Flow_Sensor,,,,brick:Condenser_Water,,quantitykind:VolumeF brick:Condenser_Water_Flow_Setpoint,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Condenser_Water_Temperature_Sensor,,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water brick:Conductivity_Sensor,,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance -brick:Contact_Sensor,,,,,,,brick:Sensor,Contact,"Senses or detects contact, such as for determining if a door is closed." +brick:Contact_Sensor,,,,,,,,,(deprecated) brick:Cooling_Command,,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) brick:Cooling_Demand_Sensor,,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Cooling_Demand_Setpoint,,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling @@ -116,16 +116,16 @@ brick:Current_Limit,,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter t brick:Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device brick:Current_Ratio_Setpoint,,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer brick:Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor -brick:Curtailment_Override_Command,,,,,,,brick:Override_Command,Curtailment, -brick:Cycle_Alarm,,,,,,,brick:Alarm,Cycle,An alarm that indicates off-normal conditions associated with HVAC cycles +brick:Curtailment_Override_Command,,,,,,,,,(deprecated) +brick:Cycle_Alarm,,,,,,,,,(deprecated) brick:Damper_Command,,,brick:Damper,,,,brick:Command,,Controls properties of dampers brick:Damper_Position_Command,,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper brick:Damper_Position_Sensor,,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open brick:Damper_Position_Setpoint,,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, -brick:DC_Bus_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,DC Bus,Measures the voltage across a DC bus +brick:DC_Bus_Voltage_Sensor,,,,,,,,,(deprecated) brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband -brick:Deceleration_Time_Setpoint,,,,,,,brick:Setpoint,Deceleration Time, +brick:Deceleration_Time_Setpoint,,,,,,,,,(deprecated) brick:Dehumidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. @@ -139,7 +139,7 @@ brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,,(deprecated) brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, @@ -201,10 +201,10 @@ brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Wa brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the domestic hot water system brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water -brick:Drive_Ready_Status,,,,,,,brick:Status,Drive Ready,"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" +brick:Drive_Ready_Status,,,,,,,,,(deprecated) brick:Duct_Air_Static_Pressure_Setpoint,,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, brick:Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,EconCycle, +brick:EconCycle_Start_Stop_Status,,,,,,,,,(deprecated) brick:Effective_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. brick:Effective_Discharge_Air_Temperature_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, @@ -219,13 +219,13 @@ brick:Electrical_Energy_Usage_Sensor,,,,,,,brick:Sensor,Electrical Energy Usage, brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, -brick:Emergency_Alarm,,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Alarm,,,,,,,,,(deprecated) brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active -brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High,,brick:Emergency_Power_Off_System,,,quantitykind:Temperature,brick:Status,Activated By, -brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,,(deprecated) +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,,(deprecated) brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, -brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed +brick:Emergency_Push_Button_Status,,,,,,,,,(deprecated) brick:Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,,Commands that enable functionality brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Enthalpy,Enables the use of differential enthalpy control brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Temperature,Enables the use of differential temperature control @@ -272,7 +272,7 @@ brick:Entering_Water_Temperature_Sensor,,,,brick:Entering_Water,,quantitykind:Te brick:Entering_Water_Temperature_Setpoint,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water brick:Enthalpy_Sensor,,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance brick:Enthalpy_Setpoint,,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy -brick:Even_Month_Status,,,,,,,brick:Status,Even Month, +brick:Even_Month_Status,,,,,,,,,(deprecated) brick:Exhaust_Air_Dewpoint_Sensor,,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air brick:Exhaust_Air_Differential_Pressure_Sensor,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building brick:Exhaust_Air_Differential_Pressure_Setpoint,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit @@ -304,25 +304,25 @@ brick:Filter_Differential_Pressure_Sensor,,,brick:Filter,,brick:Differential,qua brick:Filter_Reset_Command,,,brick:Filter,,,,brick:Reset_Command,, brick:Filter_Status,,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced brick:Filter_Water_Differential_Pressure_Sensor,,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. -brick:Fire_Sensor,,,,,,,brick:Sensor,Fire,Measures the presence of fire +brick:Fire_Sensor,,,,,,,,,(deprecated) brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen +brick:Freeze_Status,,,,,,,,,(deprecated) brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency brick:Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood -brick:Gain_Parameter,,,,,,,brick:Parameter,Gain, +brick:Gain_Parameter,,,,,,,,,(deprecated) brick:Gas_Sensor,,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. +brick:Heat_Sink_Temperature_Sensor,,,,,,,,,(deprecated) brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Heating_Demand_Setpoint,,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating @@ -343,16 +343,16 @@ brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quan brick:High_Air_Flow_Alarm,brick:High,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is higher than normal. brick:High_CO2_Alarm,brick:High,,,brick:CO2,,,brick:Alarm,,A device that indicates high concentration of carbon dioxide. brick:High_Discharge_Air_Temperature_Alarm,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,brick:High,,,,,quantitykind:Pressure,brick:Alarm,Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Head_Pressure_Alarm,,,,,,,,,(deprecated) brick:High_Humidity_Alarm,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too high -brick:High_Static_Pressure_Cutout_Setpoint_Limit,brick:High,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,Cutout,A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,,(deprecated) brick:High_Supply_Air_Temperature_Alarm,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, brick:High_Temperature_Alarm,brick:High,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates high temperature. brick:High_Temperature_Alarm_Parameter,brick:High,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm -brick:Hold_Status,,,,,,,brick:Status,Hold, +brick:Hold_Status,,,,,,,,,(deprecated) brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, @@ -383,10 +383,10 @@ brick:Illuminance_Setpoint,,,,,,quantitykind:Illuminance,brick:Setpoint,,Target brick:Imbalance_Sensor,,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system brick:Inside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. -brick:Intake_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Intake,Measures air at the interface between the building and the outside +brick:Intake_Air_Temperature_Sensor,,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside brick:Integral_Gain_Parameter,,,,,,,brick:Integral_Gain_Parameter,, brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred +brick:Last_Fault_Code_Status,,,,,,,,,(deprecated) brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled brick:Lead_On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" @@ -439,21 +439,21 @@ brick:Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,,Controls load sheddi brick:Load_Shed_Differential_Pressure_Setpoint,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Load_Shed_Setpoint,,,brick:Load_Shed,,,,brick:Setpoint,, brick:Load_Shed_Status,,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Locally, +brick:Locally_On_Off_Status,,,,,,,,,(deprecated) brick:Lockout_Status,,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" brick:Lockout_Temperature_Differential_Parameter,,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Low_Air_Flow_Alarm,brick:Low,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is lower than normal. brick:Low_Battery_Alarm,brick:Low,,brick:Battery,,,,brick:Alarm,,An alarm that indicates the battery is low. brick:Low_Discharge_Air_Flow_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the discharge air flow is lower than normal. brick:Low_Discharge_Air_Temperature_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,, -brick:Low_Freeze_Protect_Temperature_Parameter,brick:Low,,,,,quantitykind:Temperature,brick:Parameter,Freeze Protect, +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,,(deprecated) brick:Low_Humidity_Alarm,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable, brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,brick:Low,,,,,quantitykind:Pressure,brick:Alarm,Suction,An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Suction_Pressure_Alarm,,,,,,,,,(deprecated) brick:Low_Supply_Air_Flow_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,, brick:Low_Supply_Air_Temperature_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, brick:Low_Temperature_Alarm,brick:Low,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates low temperature. @@ -542,7 +542,7 @@ brick:Mixed_Air_Temperature_Sensor,,,,brick:Mixed_Air,,quantitykind:Temperature, brick:Mixed_Air_Temperature_Setpoint,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air brick:Mode_Command,,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the operating mode of a device or controller brick:Mode_Status,,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" -brick:Motion_Sensor,,,,,,,brick:Sensor,Motion,Detects the presence of motion in some area +brick:Motion_Sensor,,,,,,brick:EnumerationKind-Motion,brick:Sensor,,Detects the presence of motion in some area brick:Motor_Current_Sensor,,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor brick:Motor_Direction_Status,,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" brick:Motor_On_Off_Status,,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, @@ -551,7 +551,7 @@ brick:Motor_Torque_Sensor,,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Mea brick:Natural_Gas_Flow_Sensor,,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas brick:Natural_Gas_Temperature_Sensor,,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas brick:Natural_Gas_Usage_Sensor,,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system +brick:No_Water_Alarm,,,,,,,,,(deprecated) brick:NO2_Level_Sensor,,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" brick:Occupancy_Count_Sensor,,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area @@ -580,16 +580,16 @@ brick:Occupied_Room_Air_Temperature_Setpoint,,brick:Occupied,,brick:Room_Air,,qu brick:Occupied_Supply_Air_Flow_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied brick:Occupied_Supply_Air_Temperature_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Occupied_Target_Zone_Air_Temperature_Setpoint,,brick:Occupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. -brick:Off_Command,,,,,,,brick:Command,Off,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" -brick:Off_Status,,,,,,,brick:Status,Off,"Indicates if a control loop, relay or equipment is off" -brick:On_Command,,,,,,,brick:Command,On,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" +brick:Off_Command,,,,,,brick:On_Off-Off,brick:Command,,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" +brick:Off_Status,,,,,,brick:On_Off-Off,brick:Status,,"Indicates if a control loop, relay or equipment is off" +brick:On_Command,,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" brick:On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" brick:On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" -brick:On_Status,,,,,,,brick:Status,On,"Indicates if a control loop, relay or equipment is on" -brick:On_Timer_Sensor,,,,,,,brick:Sensor,On Timer,"Measures the duration for which a device was in an active or ""on"" state" +brick:On_Status,,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" +brick:On_Timer_Sensor,,,,,,,,,(deprecated) brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve -brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,,,(deprecated) brick:Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" brick:Output_Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,Output, brick:Output_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device @@ -613,19 +613,19 @@ brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind brick:Outside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. brick:Outside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. brick:Outside_Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" -brick:Overload_Alarm,,,,,,,brick:Alarm,Overload,An alarm that can indicate when a full-load current is exceeded. -brick:Overridden_Off_Status,,,,,,,brick:Status,Overridden Off,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" -brick:Overridden_On_Status,,,,,,,brick:Status,Overridden On,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" +brick:Overload_Alarm,,,,,,,,,(deprecated) +brick:Overridden_Off_Status,,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" +brick:Overridden_On_Status,,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" brick:Overridden_Status,,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden brick:Override_Command,,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' brick:Ozone_Level_Sensor,,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air brick:Parameter,,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values brick:Particulate_Matter_Sensor,,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air brick:Peak_Demand_Sensor,brick:Peak,,,,,,brick:Demand_Sensor,,The peak power consumed by a process over some period of time -brick:Photovoltaic_Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Photovoltaic Output,Senses the amperes of electrical current produced as output by a photovoltaic device -brick:PID_Parameter,,,,,,,brick:Parameter,PID, -brick:Piezoelectric_Sensor,,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" -brick:PIR_Sensor,,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:Photovoltaic_Current_Output_Sensor,,,,,,,,,(deprecated) +brick:PID_Parameter,,,,,,,,,(deprecated) +brick:Piezoelectric_Sensor,,,,,,,,,(deprecated) +brick:PIR_Sensor,,,,,,,,,(deprecated) brick:PM1_Level_Sensor,,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns brick:PM1_Sensor,,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron brick:PM10_Level_Sensor,,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns @@ -653,20 +653,20 @@ brick:Proportional_Gain_Parameter,,,,,,,brick:Proportional_Gain_Parameter,, brick:Pump_Command,,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) brick:Pump_On_Off_Status,,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Pump_Status,,,brick:Pump,,,,brick:Status,,Status of a pump -brick:PV_Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,PV Output,See Photovoltaic_Current_Output_Sensor +brick:PV_Current_Output_Sensor,,,,,,,,,(deprecated) brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. brick:Radon_Concentration_Sensor,,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed +brick:Rated_Speed_Setpoint,,,,,,,,,(deprecated) brick:Reactive_Energy_Sensor,,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,,brick:Refrigerant,,,brick:Sensor,Level, -brick:Reheat_Command,,,,,,,brick:Command,Reheat,"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Reheat_Command,,,,,,,,,(deprecated) brick:Relative_Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Remotely, +brick:Remotely_On_Off_Status,,,,,,,,,(deprecated) brick:Reset_Command,,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" brick:Reset_Setpoint,,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies brick:Return_Air_CO_Sensor,,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air @@ -688,16 +688,16 @@ brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperat brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air brick:Run_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Run, -brick:Run_Request_Status,,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment +brick:Run_Request_Status,,,,,,,,,(deprecated) brick:Run_Status,,,,,,,brick:Status,Run, brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" -brick:Sash_Position_Sensor,,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open -brick:Schedule_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule +brick:Sash_Position_Sensor,,,,,,,,,(deprecated) +brick:Schedule_Temperature_Setpoint,,,,,,,,,(deprecated) brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). -brick:Sensor_Failure_Alarm,,,,,,,brick:Failure_Alarm,Sensor, +brick:Sensor_Failure_Alarm,,,,,,,,,(deprecated) brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set -brick:Short_Cycle_Alarm,,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle -brick:Smoke_Alarm,,,,,,,brick:Alarm,Smoke,An alarm that indicates the off-normal conditions associated with smoke. +brick:Short_Cycle_Alarm,,,,,,,,,(deprecated) +brick:Smoke_Alarm,,,,,,,,,(deprecated) brick:Smoke_Detection_Alarm,,,brick:Smoke_Detection,,,,brick:Alarm,, brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun @@ -709,10 +709,10 @@ brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed brick:Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. -brick:Stage_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Stage,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property -brick:Stages_Status,,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in +brick:Stage_Enable_Command,,,,,,,,,(deprecated) +brick:Stages_Status,,,,,,,,,(deprecated) brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Glycool Unit,Indicates the on/off status of a standby glycool unit +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,,(deprecated) brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, brick:Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Standby, brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, @@ -769,7 +769,7 @@ brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick: brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, -brick:Temperature_Adjust_Sensor,,,,,,quantitykind:Temperature,brick:Adjust_Sensor,,Measures user-provided adjustment of temperature +brick:Temperature_Adjust_Sensor,,,,,,,,,(deprecated) brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature @@ -781,7 +781,7 @@ brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures te brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature brick:Temperature_Step_Parameter,,,,,,quantitykind:Temperature,brick:Step_Parameter,, brick:Temperature_Tolerance_Parameter,,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. -brick:Temporary_Occupancy_Status,,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Temporary_Occupancy_Status,,,,,,,,,(deprecated) brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,,brick:Thermostat,,,,brick:Status,,Status of a thermostat @@ -795,7 +795,7 @@ brick:TVOC_Level_Sensor,,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the brick:TVOC_Sensor,,,,brick:VOC,,,brick:Sensor,, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure -brick:Underfloor_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air +brick:Underfloor_Air_Temperature_Sensor,,,,,,,,,(deprecated) brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied @@ -828,16 +828,16 @@ brick:Valve_Position_Sensor,,,brick:Valve,,,,brick:Sensor,Position,Measures the brick:Valve_Status,,,brick:Valve,,,,brick:Status,,The current status of the valve. brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,Vent,Indicates the current operating mode of a vent -brick:Ventilation_Air_Flow_Ratio_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:Vent_Operating_Mode_Status,,,,,,,,,(deprecated) +brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,,(deprecated) brick:VFD_Enable_Command,,,brick:VFD,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object -brick:Warm_Cool_Adjust_Sensor,,,,,,,brick:Adjust_Sensor,Warm Cool,"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warm_Cool_Adjust_Sensor,,,,,,,,,(deprecated) brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' -brick:Waste_Amount_Sensor,,,,,,,brick:Sensor,Waste Amount,A metric used for measuring the quantity of waste generated in a building. +brick:Waste_Amount_Sensor,,,,,,,,,(deprecated) brick:Water_Alarm,,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" brick:Water_Differential_Pressure_Sensor,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. brick:Water_Differential_Pressure_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit From a5d85c602e2b75c664a1965a06eb1a75ace39254 Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 01:30:43 +0100 Subject: [PATCH 15/31] Define all point attributes [no ci] --- bricksrc/points.csv | 114 ++++++++++++++++++++++---------------------- 1 file changed, 57 insertions(+), 57 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 69af4721..d8fe7e35 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,8 +1,8 @@ @id,brick:isAggregated,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity -brick:Acceleration_Time_Setpoint,,,,,,,,,(deprecated) +brick:Acceleration_Time_Setpoint,,,,,,,,(deprecated), brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" -brick:Adjust_Sensor,,,,,,,,,(deprecated) +brick:Adjust_Sensor,,,,,,,,(deprecated), brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, brick:Air_Differential_Pressure_Sensor,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air brick:Air_Differential_Pressure_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit @@ -43,13 +43,13 @@ brick:Average_Supply_Air_Flow_Sensor,brick:Average,,,brick:Supply_Air,,quantityk brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" brick:Battery_Voltage_Sensor,,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery brick:Boiler_Command,,,brick:Boiler,,,,brick:Command,,A command to control a boiler -brick:Box_Mode_Command,,,,,,,,,(deprecated) +brick:Box_Mode_Command,,,,,,,,(deprecated), brick:Building_Air_Humidity_Setpoint,,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building brick:Building_Air_Static_Pressure_Sensor,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building brick:Building_Air_Static_Pressure_Setpoint,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building brick:Bypass_Air_Flow_Sensor,,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air brick:Bypass_Air_Humidity_Setpoint,,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air -brick:Bypass_Command,,,,,,,,,(deprecated) +brick:Bypass_Command,,,,,,,,(deprecated), brick:Bypass_Water_Flow_Sensor,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water brick:Bypass_Water_Flow_Setpoint,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water brick:Capacity_Sensor,,,,,,quantitykind:Capacity,brick:Sensor,, @@ -71,7 +71,7 @@ brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykin brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the chilled water system brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water -brick:Close_Limit,,,,,,,,,(deprecated) +brick:Close_Limit,,,,,,,,(deprecated), brick:CO_Differential_Sensor,,,,brick:CO,brick:Differential,,brick:Sensor,, brick:CO_Level_Sensor,,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO brick:CO_Sensor,,,,brick:CO,,,brick:Sensor,,Measures properties of CO @@ -92,7 +92,7 @@ brick:Condenser_Water_Flow_Sensor,,,,brick:Condenser_Water,,quantitykind:VolumeF brick:Condenser_Water_Flow_Setpoint,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Condenser_Water_Temperature_Sensor,,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water brick:Conductivity_Sensor,,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance -brick:Contact_Sensor,,,,,,,,,(deprecated) +brick:Contact_Sensor,,,,,,,,(deprecated), brick:Cooling_Command,,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) brick:Cooling_Demand_Sensor,,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Cooling_Demand_Setpoint,,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling @@ -116,16 +116,16 @@ brick:Current_Limit,,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter t brick:Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device brick:Current_Ratio_Setpoint,,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer brick:Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor -brick:Curtailment_Override_Command,,,,,,,,,(deprecated) -brick:Cycle_Alarm,,,,,,,,,(deprecated) +brick:Curtailment_Override_Command,,,,,,,,(deprecated), +brick:Cycle_Alarm,,,,,,,,(deprecated), brick:Damper_Command,,,brick:Damper,,,,brick:Command,,Controls properties of dampers brick:Damper_Position_Command,,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper brick:Damper_Position_Sensor,,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open brick:Damper_Position_Setpoint,,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, -brick:DC_Bus_Voltage_Sensor,,,,,,,,,(deprecated) +brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated), brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband -brick:Deceleration_Time_Setpoint,,,,,,,,,(deprecated) +brick:Deceleration_Time_Setpoint,,,,,,,,(deprecated), brick:Dehumidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. @@ -139,7 +139,7 @@ brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,,(deprecated) +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,(deprecated), brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, @@ -201,10 +201,10 @@ brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Wa brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the domestic hot water system brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water -brick:Drive_Ready_Status,,,,,,,,,(deprecated) +brick:Drive_Ready_Status,,,,,,,,(deprecated), brick:Duct_Air_Static_Pressure_Setpoint,,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, brick:Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,,,,,(deprecated) +brick:EconCycle_Start_Stop_Status,,,,,,,,(deprecated), brick:Effective_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. brick:Effective_Discharge_Air_Temperature_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, @@ -219,13 +219,13 @@ brick:Electrical_Energy_Usage_Sensor,,,,,,,brick:Sensor,Electrical Energy Usage, brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, -brick:Emergency_Alarm,,,,,,,,,(deprecated) +brick:Emergency_Alarm,,,,,,,,(deprecated), brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active -brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,,(deprecated) -brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,,(deprecated) +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,(deprecated), brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, -brick:Emergency_Push_Button_Status,,,,,,,,,(deprecated) +brick:Emergency_Push_Button_Status,,,,,,,,(deprecated), brick:Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,,Commands that enable functionality brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Enthalpy,Enables the use of differential enthalpy control brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Temperature,Enables the use of differential temperature control @@ -272,7 +272,7 @@ brick:Entering_Water_Temperature_Sensor,,,,brick:Entering_Water,,quantitykind:Te brick:Entering_Water_Temperature_Setpoint,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water brick:Enthalpy_Sensor,,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance brick:Enthalpy_Setpoint,,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy -brick:Even_Month_Status,,,,,,,,,(deprecated) +brick:Even_Month_Status,,,,,,,,(deprecated), brick:Exhaust_Air_Dewpoint_Sensor,,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air brick:Exhaust_Air_Differential_Pressure_Sensor,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building brick:Exhaust_Air_Differential_Pressure_Setpoint,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit @@ -304,25 +304,25 @@ brick:Filter_Differential_Pressure_Sensor,,,brick:Filter,,brick:Differential,qua brick:Filter_Reset_Command,,,brick:Filter,,,,brick:Reset_Command,, brick:Filter_Status,,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced brick:Filter_Water_Differential_Pressure_Sensor,,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. -brick:Fire_Sensor,,,,,,,,,(deprecated) +brick:Fire_Sensor,,,,,,,,(deprecated), brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,,,,(deprecated) +brick:Freeze_Status,,,,,,,,(deprecated), brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency brick:Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood -brick:Gain_Parameter,,,,,,,,,(deprecated) +brick:Gain_Parameter,,,,,,,,(deprecated), brick:Gas_Sensor,,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,,,,,(deprecated) +brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated), brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Heating_Demand_Setpoint,,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating @@ -343,16 +343,16 @@ brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quan brick:High_Air_Flow_Alarm,brick:High,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is higher than normal. brick:High_CO2_Alarm,brick:High,,,brick:CO2,,,brick:Alarm,,A device that indicates high concentration of carbon dioxide. brick:High_Discharge_Air_Temperature_Alarm,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,,,,,,,,,(deprecated) +brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated), brick:High_Humidity_Alarm,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too high -brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,,(deprecated) +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated), brick:High_Supply_Air_Temperature_Alarm,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, brick:High_Temperature_Alarm,brick:High,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates high temperature. brick:High_Temperature_Alarm_Parameter,brick:High,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm -brick:Hold_Status,,,,,,,,,(deprecated) +brick:Hold_Status,,,,,,,,(deprecated), brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, @@ -386,7 +386,7 @@ brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,bri brick:Intake_Air_Temperature_Sensor,,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside brick:Integral_Gain_Parameter,,,,,,,brick:Integral_Gain_Parameter,, brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,,,,(deprecated) +brick:Last_Fault_Code_Status,,,,,,,,(deprecated), brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled brick:Lead_On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" @@ -439,21 +439,21 @@ brick:Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,,Controls load sheddi brick:Load_Shed_Differential_Pressure_Setpoint,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Load_Shed_Setpoint,,,brick:Load_Shed,,,,brick:Setpoint,, brick:Load_Shed_Status,,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,,,,,(deprecated) +brick:Locally_On_Off_Status,,,,,,,,(deprecated), brick:Lockout_Status,,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" brick:Lockout_Temperature_Differential_Parameter,,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Low_Air_Flow_Alarm,brick:Low,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is lower than normal. brick:Low_Battery_Alarm,brick:Low,,brick:Battery,,,,brick:Alarm,,An alarm that indicates the battery is low. brick:Low_Discharge_Air_Flow_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the discharge air flow is lower than normal. brick:Low_Discharge_Air_Temperature_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,, -brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,,(deprecated) +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,(deprecated), brick:Low_Humidity_Alarm,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable, brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,,,,,,,,,(deprecated) +brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated), brick:Low_Supply_Air_Flow_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,, brick:Low_Supply_Air_Temperature_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, brick:Low_Temperature_Alarm,brick:Low,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates low temperature. @@ -551,7 +551,7 @@ brick:Motor_Torque_Sensor,,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Mea brick:Natural_Gas_Flow_Sensor,,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas brick:Natural_Gas_Temperature_Sensor,,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas brick:Natural_Gas_Usage_Sensor,,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,,,,,,,(deprecated) +brick:No_Water_Alarm,,,,,,,,(deprecated), brick:NO2_Level_Sensor,,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" brick:Occupancy_Count_Sensor,,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area @@ -586,10 +586,10 @@ brick:On_Command,,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or brick:On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" brick:On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" brick:On_Status,,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" -brick:On_Timer_Sensor,,,,,,,,,(deprecated) +brick:On_Timer_Sensor,,,,,,,,(deprecated), brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve -brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,,,(deprecated) +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,,(deprecated), brick:Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" brick:Output_Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,Output, brick:Output_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device @@ -613,7 +613,7 @@ brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind brick:Outside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. brick:Outside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. brick:Outside_Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" -brick:Overload_Alarm,,,,,,,,,(deprecated) +brick:Overload_Alarm,,,,,,,,(deprecated), brick:Overridden_Off_Status,,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" brick:Overridden_On_Status,,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" brick:Overridden_Status,,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden @@ -622,10 +622,10 @@ brick:Ozone_Level_Sensor,,,,brick:O3,,,brick:Sensor,Level,Measures the concentra brick:Parameter,,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values brick:Particulate_Matter_Sensor,,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air brick:Peak_Demand_Sensor,brick:Peak,,,,,,brick:Demand_Sensor,,The peak power consumed by a process over some period of time -brick:Photovoltaic_Current_Output_Sensor,,,,,,,,,(deprecated) -brick:PID_Parameter,,,,,,,,,(deprecated) -brick:Piezoelectric_Sensor,,,,,,,,,(deprecated) -brick:PIR_Sensor,,,,,,,,,(deprecated) +brick:Photovoltaic_Current_Output_Sensor,,,,,,,,(deprecated), +brick:PID_Parameter,,,,,,,,(deprecated), +brick:Piezoelectric_Sensor,,,,,,,,(deprecated), +brick:PIR_Sensor,,,,,,,,(deprecated), brick:PM1_Level_Sensor,,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns brick:PM1_Sensor,,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron brick:PM10_Level_Sensor,,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns @@ -653,20 +653,20 @@ brick:Proportional_Gain_Parameter,,,,,,,brick:Proportional_Gain_Parameter,, brick:Pump_Command,,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) brick:Pump_On_Off_Status,,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Pump_Status,,,brick:Pump,,,,brick:Status,,Status of a pump -brick:PV_Current_Output_Sensor,,,,,,,,,(deprecated) +brick:PV_Current_Output_Sensor,,,,,,,,(deprecated), brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. brick:Radon_Concentration_Sensor,,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,,,,,(deprecated) +brick:Rated_Speed_Setpoint,,,,,,,,(deprecated), brick:Reactive_Energy_Sensor,,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,,brick:Refrigerant,,,brick:Sensor,Level, -brick:Reheat_Command,,,,,,,,,(deprecated) +brick:Reheat_Command,,,,,,,,(deprecated), brick:Relative_Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,,,,,(deprecated) +brick:Remotely_On_Off_Status,,,,,,,,(deprecated), brick:Reset_Command,,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" brick:Reset_Setpoint,,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies brick:Return_Air_CO_Sensor,,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air @@ -688,16 +688,16 @@ brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperat brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air brick:Run_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Run, -brick:Run_Request_Status,,,,,,,,,(deprecated) +brick:Run_Request_Status,,,,,,,,(deprecated), brick:Run_Status,,,,,,,brick:Status,Run, brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" -brick:Sash_Position_Sensor,,,,,,,,,(deprecated) -brick:Schedule_Temperature_Setpoint,,,,,,,,,(deprecated) +brick:Sash_Position_Sensor,,,,,,,,(deprecated), +brick:Schedule_Temperature_Setpoint,,,,,,,,(deprecated), brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). -brick:Sensor_Failure_Alarm,,,,,,,,,(deprecated) +brick:Sensor_Failure_Alarm,,,,,,,,(deprecated), brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set -brick:Short_Cycle_Alarm,,,,,,,,,(deprecated) -brick:Smoke_Alarm,,,,,,,,,(deprecated) +brick:Short_Cycle_Alarm,,,,,,,,(deprecated), +brick:Smoke_Alarm,,,,,,,,(deprecated), brick:Smoke_Detection_Alarm,,,brick:Smoke_Detection,,,,brick:Alarm,, brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun @@ -709,10 +709,10 @@ brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed brick:Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. -brick:Stage_Enable_Command,,,,,,,,,(deprecated) -brick:Stages_Status,,,,,,,,,(deprecated) +brick:Stage_Enable_Command,,,,,,,,(deprecated), +brick:Stages_Status,,,,,,,,(deprecated), brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,,(deprecated) +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,(deprecated), brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, brick:Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Standby, brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, @@ -769,7 +769,7 @@ brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick: brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, -brick:Temperature_Adjust_Sensor,,,,,,,,,(deprecated) +brick:Temperature_Adjust_Sensor,,,,,,,,(deprecated), brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature @@ -781,7 +781,7 @@ brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures te brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature brick:Temperature_Step_Parameter,,,,,,quantitykind:Temperature,brick:Step_Parameter,, brick:Temperature_Tolerance_Parameter,,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. -brick:Temporary_Occupancy_Status,,,,,,,,,(deprecated) +brick:Temporary_Occupancy_Status,,,,,,,,(deprecated), brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,,brick:Thermostat,,,,brick:Status,,Status of a thermostat @@ -795,7 +795,7 @@ brick:TVOC_Level_Sensor,,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the brick:TVOC_Sensor,,,,brick:VOC,,,brick:Sensor,, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure -brick:Underfloor_Air_Temperature_Sensor,,,,,,,,,(deprecated) +brick:Underfloor_Air_Temperature_Sensor,,,,,,,,(deprecated), brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied @@ -828,16 +828,16 @@ brick:Valve_Position_Sensor,,,brick:Valve,,,,brick:Sensor,Position,Measures the brick:Valve_Status,,,brick:Valve,,,,brick:Status,,The current status of the valve. brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,,,,(deprecated) -brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,,(deprecated) +brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated), +brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated), brick:VFD_Enable_Command,,,brick:VFD,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object -brick:Warm_Cool_Adjust_Sensor,,,,,,,,,(deprecated) +brick:Warm_Cool_Adjust_Sensor,,,,,,,,(deprecated), brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' -brick:Waste_Amount_Sensor,,,,,,,,,(deprecated) +brick:Waste_Amount_Sensor,,,,,,,,(deprecated), brick:Water_Alarm,,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" brick:Water_Differential_Pressure_Sensor,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. brick:Water_Differential_Pressure_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit From 338abddbd418ffbf07e33f2721b688c6d4988747 Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 01:32:39 +0100 Subject: [PATCH 16/31] Define all point attributes [no ci] --- bricksrc/points.csv | 80 ++++++++++++++++++++++----------------------- 1 file changed, 40 insertions(+), 40 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index d8fe7e35..8e2624a3 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -2,7 +2,7 @@ brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity brick:Acceleration_Time_Setpoint,,,,,,,,(deprecated), brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" -brick:Adjust_Sensor,,,,,,,,(deprecated), +brick:Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of some value brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, brick:Air_Differential_Pressure_Sensor,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air brick:Air_Differential_Pressure_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit @@ -71,7 +71,7 @@ brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykin brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the chilled water system brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water -brick:Close_Limit,,,,,,,,(deprecated), +brick:Close_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. brick:CO_Differential_Sensor,,,,brick:CO,brick:Differential,,brick:Sensor,, brick:CO_Level_Sensor,,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO brick:CO_Sensor,,,,brick:CO,,,brick:Sensor,,Measures properties of CO @@ -92,7 +92,7 @@ brick:Condenser_Water_Flow_Sensor,,,,brick:Condenser_Water,,quantitykind:VolumeF brick:Condenser_Water_Flow_Setpoint,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, brick:Condenser_Water_Temperature_Sensor,,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water brick:Conductivity_Sensor,,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance -brick:Contact_Sensor,,,,,,,,(deprecated), +brick:Contact_Sensor,,,,,,,,(deprecated),"Senses or detects contact, such as for determining if a door is closed." brick:Cooling_Command,,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) brick:Cooling_Demand_Sensor,,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Cooling_Demand_Setpoint,,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling @@ -117,13 +117,13 @@ brick:Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Outpu brick:Current_Ratio_Setpoint,,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer brick:Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor brick:Curtailment_Override_Command,,,,,,,,(deprecated), -brick:Cycle_Alarm,,,,,,,,(deprecated), +brick:Cycle_Alarm,,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with HVAC cycles brick:Damper_Command,,,brick:Damper,,,,brick:Command,,Controls properties of dampers brick:Damper_Position_Command,,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper brick:Damper_Position_Sensor,,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open brick:Damper_Position_Setpoint,,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, -brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated), +brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated),Measures the voltage across a DC bus brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband brick:Deceleration_Time_Setpoint,,,,,,,,(deprecated), brick:Dehumidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, @@ -139,7 +139,7 @@ brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,(deprecated), +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,(deprecated),Measures the difference in temperature between entering and leaving water of water a circuit brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, @@ -201,7 +201,7 @@ brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Wa brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the domestic hot water system brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water -brick:Drive_Ready_Status,,,,,,,,(deprecated), +brick:Drive_Ready_Status,,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" brick:Duct_Air_Static_Pressure_Setpoint,,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, brick:Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event brick:EconCycle_Start_Stop_Status,,,,,,,,(deprecated), @@ -219,13 +219,13 @@ brick:Electrical_Energy_Usage_Sensor,,,,,,,brick:Sensor,Electrical Energy Usage, brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, -brick:Emergency_Alarm,,,,,,,,(deprecated), +brick:Emergency_Alarm,,,,,,,,(deprecated),Alarms that indicate off-normal conditions associated with emergency systems brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,(deprecated), brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,(deprecated), brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, -brick:Emergency_Push_Button_Status,,,,,,,,(deprecated), +brick:Emergency_Push_Button_Status,,,,,,,,(deprecated),Indicates if an emergency button has been pushed brick:Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,,Commands that enable functionality brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Enthalpy,Enables the use of differential enthalpy control brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Temperature,Enables the use of differential temperature control @@ -304,11 +304,11 @@ brick:Filter_Differential_Pressure_Sensor,,,brick:Filter,,brick:Differential,qua brick:Filter_Reset_Command,,,brick:Filter,,,,brick:Reset_Command,, brick:Filter_Status,,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced brick:Filter_Water_Differential_Pressure_Sensor,,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. -brick:Fire_Sensor,,,,,,,,(deprecated), +brick:Fire_Sensor,,,,,,,,(deprecated),Measures the presence of fire brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,,,(deprecated), +brick:Freeze_Status,,,,,,,,(deprecated),Indicates if a substance contained within a vessel has frozen brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency @@ -322,7 +322,7 @@ brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how muc brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated), +brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Heating_Demand_Setpoint,,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating @@ -343,12 +343,12 @@ brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quan brick:High_Air_Flow_Alarm,brick:High,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is higher than normal. brick:High_CO2_Alarm,brick:High,,,brick:CO2,,,brick:Alarm,,A device that indicates high concentration of carbon dioxide. brick:High_Discharge_Air_Temperature_Alarm,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated), +brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. brick:High_Humidity_Alarm,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too high -brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated), +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. brick:High_Supply_Air_Temperature_Alarm,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, brick:High_Temperature_Alarm,brick:High,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates high temperature. brick:High_Temperature_Alarm_Parameter,brick:High,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm @@ -386,7 +386,7 @@ brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,bri brick:Intake_Air_Temperature_Sensor,,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside brick:Integral_Gain_Parameter,,,,,,,brick:Integral_Gain_Parameter,, brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,,,(deprecated), +brick:Last_Fault_Code_Status,,,,,,,,(deprecated),Indicates the last fault code that occurred brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled brick:Lead_On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" @@ -453,7 +453,7 @@ brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,,bri brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable, brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated), +brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. brick:Low_Supply_Air_Flow_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,, brick:Low_Supply_Air_Temperature_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, brick:Low_Temperature_Alarm,brick:Low,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates low temperature. @@ -551,7 +551,7 @@ brick:Motor_Torque_Sensor,,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Mea brick:Natural_Gas_Flow_Sensor,,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas brick:Natural_Gas_Temperature_Sensor,,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas brick:Natural_Gas_Usage_Sensor,,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,,,,,,(deprecated), +brick:No_Water_Alarm,,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system brick:NO2_Level_Sensor,,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" brick:Occupancy_Count_Sensor,,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area @@ -586,7 +586,7 @@ brick:On_Command,,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or brick:On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" brick:On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" brick:On_Status,,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" -brick:On_Timer_Sensor,,,,,,,,(deprecated), +brick:On_Timer_Sensor,,,,,,,,(deprecated),"Measures the duration for which a device was in an active or ""on"" state" brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,,(deprecated), @@ -613,7 +613,7 @@ brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind brick:Outside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. brick:Outside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. brick:Outside_Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" -brick:Overload_Alarm,,,,,,,,(deprecated), +brick:Overload_Alarm,,,,,,,,(deprecated),An alarm that can indicate when a full-load current is exceeded. brick:Overridden_Off_Status,,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" brick:Overridden_On_Status,,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" brick:Overridden_Status,,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden @@ -622,10 +622,10 @@ brick:Ozone_Level_Sensor,,,,brick:O3,,,brick:Sensor,Level,Measures the concentra brick:Parameter,,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values brick:Particulate_Matter_Sensor,,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air brick:Peak_Demand_Sensor,brick:Peak,,,,,,brick:Demand_Sensor,,The peak power consumed by a process over some period of time -brick:Photovoltaic_Current_Output_Sensor,,,,,,,,(deprecated), +brick:Photovoltaic_Current_Output_Sensor,,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device brick:PID_Parameter,,,,,,,,(deprecated), -brick:Piezoelectric_Sensor,,,,,,,,(deprecated), -brick:PIR_Sensor,,,,,,,,(deprecated), +brick:Piezoelectric_Sensor,,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors brick:PM1_Level_Sensor,,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns brick:PM1_Sensor,,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron brick:PM10_Level_Sensor,,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns @@ -653,17 +653,17 @@ brick:Proportional_Gain_Parameter,,,,,,,brick:Proportional_Gain_Parameter,, brick:Pump_Command,,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) brick:Pump_On_Off_Status,,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Pump_Status,,,brick:Pump,,,,brick:Status,,Status of a pump -brick:PV_Current_Output_Sensor,,,,,,,,(deprecated), +brick:PV_Current_Output_Sensor,,,,,,,,(deprecated),See Photovoltaic_Current_Output_Sensor brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. brick:Radon_Concentration_Sensor,,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,,,,(deprecated), +brick:Rated_Speed_Setpoint,,,,,,,,(deprecated),Sets rated speed brick:Reactive_Energy_Sensor,,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,,brick:Refrigerant,,,brick:Sensor,Level, -brick:Reheat_Command,,,,,,,,(deprecated), +brick:Reheat_Command,,,,,,,,(deprecated),"A command to activate reheating, which is used for either heating or for dehumidification purposes" brick:Relative_Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,,brick:Relay,,,,brick:Command,,Commands to switch the relay brick:Remotely_On_Off_Status,,,,,,,,(deprecated), @@ -688,16 +688,16 @@ brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperat brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air brick:Run_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Run, -brick:Run_Request_Status,,,,,,,,(deprecated), +brick:Run_Request_Status,,,,,,,,(deprecated),Indicates if a request has been filed to start a device or equipment brick:Run_Status,,,,,,,brick:Status,Run, brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" -brick:Sash_Position_Sensor,,,,,,,,(deprecated), -brick:Schedule_Temperature_Setpoint,,,,,,,,(deprecated), +brick:Sash_Position_Sensor,,,,,,,,(deprecated),Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,,,,(deprecated),The current setpoint as indicated by the schedule brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). brick:Sensor_Failure_Alarm,,,,,,,,(deprecated), brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set -brick:Short_Cycle_Alarm,,,,,,,,(deprecated), -brick:Smoke_Alarm,,,,,,,,(deprecated), +brick:Short_Cycle_Alarm,,,,,,,,(deprecated),An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Smoke_Alarm,,,,,,,,(deprecated),An alarm that indicates the off-normal conditions associated with smoke. brick:Smoke_Detection_Alarm,,,brick:Smoke_Detection,,,,brick:Alarm,, brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun @@ -709,10 +709,10 @@ brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed brick:Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. -brick:Stage_Enable_Command,,,,,,,,(deprecated), -brick:Stages_Status,,,,,,,,(deprecated), +brick:Stage_Enable_Command,,,,,,,,(deprecated),A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,,,(deprecated),Indicates which stage a control loop or equipment is in brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,(deprecated), +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, brick:Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Standby, brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, @@ -769,7 +769,7 @@ brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick: brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, -brick:Temperature_Adjust_Sensor,,,,,,,,(deprecated), +brick:Temperature_Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of temperature brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature @@ -781,7 +781,7 @@ brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures te brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature brick:Temperature_Step_Parameter,,,,,,quantitykind:Temperature,brick:Step_Parameter,, brick:Temperature_Tolerance_Parameter,,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. -brick:Temporary_Occupancy_Status,,,,,,,,(deprecated), +brick:Temporary_Occupancy_Status,,,,,,,,(deprecated),"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,,brick:Thermostat,,,,brick:Status,,Status of a thermostat @@ -795,7 +795,7 @@ brick:TVOC_Level_Sensor,,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the brick:TVOC_Sensor,,,,brick:VOC,,,brick:Sensor,, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure -brick:Underfloor_Air_Temperature_Sensor,,,,,,,,(deprecated), +brick:Underfloor_Air_Temperature_Sensor,,,,,,,,(deprecated),Measures the temperature of underfloor air brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied @@ -828,16 +828,16 @@ brick:Valve_Position_Sensor,,,brick:Valve,,,,brick:Sensor,Position,Measures the brick:Valve_Status,,,brick:Valve,,,,brick:Status,,The current status of the valve. brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated), -brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated), +brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated),Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. brick:VFD_Enable_Command,,,brick:VFD,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object -brick:Warm_Cool_Adjust_Sensor,,,,,,,,(deprecated), +brick:Warm_Cool_Adjust_Sensor,,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' -brick:Waste_Amount_Sensor,,,,,,,,(deprecated), +brick:Waste_Amount_Sensor,,,,,,,,(deprecated),A metric used for measuring the quantity of waste generated in a building. brick:Water_Alarm,,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" brick:Water_Differential_Pressure_Sensor,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. brick:Water_Differential_Pressure_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit From 482b4368faf03ba17aee4f5ef054cdec02af07af Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 01:43:26 +0100 Subject: [PATCH 17/31] Define all point attributes [no ci] --- bricksrc/points.csv | 24 ++++++++++++------------ 1 file changed, 12 insertions(+), 12 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 8e2624a3..d4f367f5 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -126,7 +126,7 @@ brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated),Measures the voltage across a DC bus brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband brick:Deceleration_Time_Setpoint,,,,,,,,(deprecated), -brick:Dehumidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Dehumidification, +brick:Dehumidification_Start_Stop_Status,,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. brick:Deionized_Water_Conductivity_Sensor,,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water @@ -219,13 +219,13 @@ brick:Electrical_Energy_Usage_Sensor,,,,,,,brick:Sensor,Electrical Energy Usage, brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, -brick:Emergency_Alarm,,,,,,,,(deprecated),Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Alarm,,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active -brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,(deprecated), -brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High,,brick:Emergency_Power_Off_System,,,quantitykind:Temperature,brick:Status,Activated By, +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, -brick:Emergency_Push_Button_Status,,,,,,,,(deprecated),Indicates if an emergency button has been pushed +brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed brick:Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,,Commands that enable functionality brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Enthalpy,Enables the use of differential enthalpy control brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Temperature,Enables the use of differential temperature control @@ -308,14 +308,14 @@ brick:Fire_Sensor,,,,,,,,(deprecated),Measures the presence of fire brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,,,(deprecated),Indicates if a substance contained within a vessel has frozen +brick:Freeze_Status,,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency brick:Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood -brick:Gain_Parameter,,,,,,,,(deprecated), +brick:Gain_Parameter,,,,,,,brick:Parameter,Gain, brick:Gas_Sensor,,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. @@ -368,7 +368,7 @@ brick:Hot_Water_Static_Pressure_Setpoint,,,,brick:Hot_Water,,quantitykind:Static brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the hot water system brick:Hot_Water_Temperature_Setpoint,,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water brick:Hot_Water_Usage_Sensor,,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" -brick:Humidification_Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,Humidification, +brick:Humidification_Start_Stop_Status,,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Humidifier_Fault_Status,,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier brick:Humidify_Command,,,,,,,brick:Command,Humidify, brick:Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. @@ -688,11 +688,11 @@ brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperat brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air brick:Run_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Run, -brick:Run_Request_Status,,,,,,,,(deprecated),Indicates if a request has been filed to start a device or equipment +brick:Run_Request_Status,,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment brick:Run_Status,,,,,,,brick:Status,Run, brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" -brick:Sash_Position_Sensor,,,,,,,,(deprecated),Measures the current position of a sash in terms of the percent of fully open -brick:Schedule_Temperature_Setpoint,,,,,,,,(deprecated),The current setpoint as indicated by the schedule +brick:Sash_Position_Sensor,,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). brick:Sensor_Failure_Alarm,,,,,,,,(deprecated), brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set @@ -795,7 +795,7 @@ brick:TVOC_Level_Sensor,,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the brick:TVOC_Sensor,,,,brick:VOC,,,brick:Sensor,, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure -brick:Underfloor_Air_Temperature_Sensor,,,,,,,,(deprecated),Measures the temperature of underfloor air +brick:Underfloor_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied From 1c83aa19f95884cf1a697caf058b899ce036d070 Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 01:50:40 +0100 Subject: [PATCH 18/31] Define all point attributes [no ci] --- bricksrc/points.csv | 44 ++++++++++++++++++++++---------------------- 1 file changed, 22 insertions(+), 22 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index d4f367f5..b868dd38 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -167,8 +167,8 @@ brick:Discharge_Air_Differential_Pressure_Sensor,,,,brick:Discharge_Air,brick:Di brick:Discharge_Air_Differential_Pressure_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Discharge_Air_Duct_Pressure_Status,,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds brick:Discharge_Air_Flow_Demand_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of discharge air flow required for a process -brick:Discharge_Air_Flow_High_Reset_Setpoint,brick:High,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, -brick:Discharge_Air_Flow_Low_Reset_Setpoint,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Discharge_Air_Flow_High_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, brick:Discharge_Air_Flow_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies brick:Discharge_Air_Flow_Sensor,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air brick:Discharge_Air_Flow_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow @@ -187,8 +187,8 @@ brick:Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Tempe brick:Discharge_Air_Temperature_Cooling_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for cooling brick:Discharge_Air_Temperature_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air brick:Discharge_Air_Temperature_Heating_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for heating -brick:Discharge_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Discharge_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, brick:Discharge_Air_Temperature_Sensor,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air @@ -248,15 +248,15 @@ brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Domesti brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Entering_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water enteringed to a hot water system brick:Entering_Hot_Water_Flow_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water brick:Entering_Hot_Water_Flow_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water -brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Entering_Hot_Water_Temperature_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system brick:Entering_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water -brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water entering a hot water system brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, @@ -403,15 +403,15 @@ brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Domestic_ brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Leaving_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water supplied by a hot water system brick:Leaving_Hot_Water_Flow_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water brick:Leaving_Hot_Water_Flow_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water -brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Leaving_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system brick:Leaving_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,brick:High,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water supplied by a hot water system brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, @@ -605,8 +605,8 @@ brick:Outside_Air_Humidity_Setpoint,,,,brick:Outside_Air,,quantitykind:RelativeH brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Outside_Air_Lockout_Temperature_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, -brick:Outside_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Outside_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Outside_Air_Temperature_High_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Outside_Air_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air brick:Outside_Air_Temperature_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air @@ -681,8 +681,8 @@ brick:Return_Air_Grains_Sensor,,,,brick:Return_Air,,,brick:Sensor,Grains,Measure brick:Return_Air_Humidity_Sensor,,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air brick:Return_Air_Humidity_Setpoint,,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air brick:Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. -brick:Return_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Return_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Return_Air_Temperature_High_Reset_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Return_Air_Temperature_Low_Reset_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Return_Air_Temperature_Sensor,,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, @@ -735,8 +735,8 @@ brick:Supply_Air_Differential_Pressure_Sensor,,,,brick:Supply_Air,brick:Differen brick:Supply_Air_Differential_Pressure_Setpoint,,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit brick:Supply_Air_Duct_Pressure_Status,,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds brick:Supply_Air_Flow_Demand_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process -brick:Supply_Air_Flow_High_Reset_Setpoint,brick:High,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, -brick:Supply_Air_Flow_Low_Reset_Setpoint,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_High_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Supply_Air_Flow_Low_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, brick:Supply_Air_Flow_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, brick:Supply_Air_Flow_Sensor,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air brick:Supply_Air_Flow_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate @@ -755,8 +755,8 @@ brick:Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature brick:Supply_Air_Temperature_Cooling_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Supply_Air_Temperature_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air brick:Supply_Air_Temperature_Heating_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Supply_Air_Temperature_High_Reset_Setpoint,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Supply_Air_Temperature_Low_Reset_Setpoint,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Supply_Air_Temperature_High_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, brick:Supply_Air_Temperature_Sensor,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air @@ -774,8 +774,8 @@ brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature brick:Temperature_Differential_Reset_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Temperature_High_Reset_Setpoint,brick:High,,,,,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Temperature_Low_Reset_Setpoint,brick:Low,,,,,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_High_Reset_Setpoint,,,,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Temperature_Low_Reset_Setpoint,,,,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Temperature_Parameter,,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature From 6298f10e3e3eadeb84f78c18d1b9e9bd14c35ce3 Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 19:57:34 +0100 Subject: [PATCH 19/31] Define all point attributes [no ci] --- bricksrc/points.csv | 42 +++++++++++++++++++++--------------------- 1 file changed, 21 insertions(+), 21 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index b868dd38..616ba8f5 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,6 +1,6 @@ @id,brick:isAggregated,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity -brick:Acceleration_Time_Setpoint,,,,,,,,(deprecated), +brick:Acceleration_Time_Setpoint,,,brick:Acceleration,,,,brick:Time_Setpoint,, brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" brick:Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of some value brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, @@ -125,7 +125,7 @@ brick:Damper_Position_Setpoint,,,brick:Damper,,,,brick:Setpoint,Position,Sets th brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated),Measures the voltage across a DC bus brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband -brick:Deceleration_Time_Setpoint,,,,,,,,(deprecated), +brick:Deceleration_Time_Setpoint,,,brick:Deceleration,,,,brick:Time_Setpoint,, brick:Dehumidification_Start_Stop_Status,,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. @@ -139,7 +139,7 @@ brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,(deprecated),Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, @@ -304,7 +304,7 @@ brick:Filter_Differential_Pressure_Sensor,,,brick:Filter,,brick:Differential,qua brick:Filter_Reset_Command,,,brick:Filter,,,,brick:Reset_Command,, brick:Filter_Status,,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced brick:Filter_Water_Differential_Pressure_Sensor,,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. -brick:Fire_Sensor,,,,,,,,(deprecated),Measures the presence of fire +brick:Fire_Sensor,,,,brick:Fire,,,brick:Sensor,,Measures the presence of fire brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air @@ -346,7 +346,7 @@ brick:High_Discharge_Air_Temperature_Alarm,brick:High,,,brick:Discharge_Air,,qua brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. brick:High_Humidity_Alarm,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm -brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The upper bound of the outside air temperature lockout range +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,,The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too high brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. brick:High_Supply_Air_Temperature_Alarm,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, @@ -440,8 +440,8 @@ brick:Load_Shed_Differential_Pressure_Setpoint,,,brick:Load_Shed,,brick:Differen brick:Load_Shed_Setpoint,,,brick:Load_Shed,,,,brick:Setpoint,, brick:Load_Shed_Status,,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect brick:Locally_On_Off_Status,,,,,,,,(deprecated), -brick:Lockout_Status,,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" -brick:Lockout_Temperature_Differential_Parameter,,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Lockout_Status,,,brick:Lockout,,,,brick:Status,,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,brick:Lockout,,brick:Differential,quantitykind:Temperature,brick:Parameter,, brick:Low_Air_Flow_Alarm,brick:Low,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is lower than normal. brick:Low_Battery_Alarm,brick:Low,,brick:Battery,,,,brick:Alarm,,An alarm that indicates the battery is low. brick:Low_Discharge_Air_Flow_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the discharge air flow is lower than normal. @@ -449,7 +449,7 @@ brick:Low_Discharge_Air_Temperature_Alarm,brick:Low,,,brick:Discharge_Air,,quant brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,(deprecated), brick:Low_Humidity_Alarm,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm -brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,,The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable, brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low @@ -465,7 +465,7 @@ brick:Luminance_Command,,,,,,quantitykind:Luminance,brick:Command,,Controls the brick:Luminance_Sensor,,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance brick:Maintenance_Mode_Command,,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" -brick:Maintenance_Required_Alarm,,,,,,brick:EnumerationKind-Maintenance_Required,brick:Alarm,,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Maintenance_Required_Alarm,,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment brick:Manual_Auto_Status,,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. brick:Max_Air_Temperature_Setpoint,brick:Maximum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature @@ -602,8 +602,8 @@ brick:Outside_Air_Flow_Setpoint,,,,brick:Outside_Air,,quantitykind:VolumeFlowRat brick:Outside_Air_Grains_Sensor,,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air brick:Outside_Air_Humidity_Sensor,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air brick:Outside_Air_Humidity_Setpoint,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air -brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, -brick:Outside_Air_Lockout_Temperature_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,, +brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Lockout,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,, brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, brick:Outside_Air_Temperature_High_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, @@ -626,10 +626,10 @@ brick:Photovoltaic_Current_Output_Sensor,,,,,,,,(deprecated),Senses the amperes brick:PID_Parameter,,,,,,,,(deprecated), brick:Piezoelectric_Sensor,,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" brick:PIR_Sensor,,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors -brick:PM1_Level_Sensor,,,,brick:PM1,,,brick:Sensor,Level,Detects level of particulates of size 1 microns -brick:PM1_Sensor,,,,brick:PM1,,,brick:Sensor,,Detects matter of size 1 micron -brick:PM10_Level_Sensor,,,,brick:PM10,,,brick:Sensor,Level,Detects level of particulates of size 10 microns -brick:PM10_Sensor,,,,brick:PM10,,,brick:Sensor,,Detects matter of size 10 microns +brick:PM1_Level_Sensor,,,,brick:PM1.0,,,brick:Sensor,Level,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,,brick:PM1.0,,,brick:Sensor,,Detects matter of size 1 micron +brick:PM10_Level_Sensor,,,,brick:PM10.0,,,brick:Sensor,Level,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,,brick:PM10.0,,,brick:Sensor,,Detects matter of size 10 microns brick:PM2.5_Level_Sensor,,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns brick:PM2.5_Sensor,,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns brick:Position_Command,,,,,,,brick:Command,Position,Controls or reports the position of some object @@ -657,8 +657,8 @@ brick:PV_Current_Output_Sensor,,,,,,,,(deprecated),See Photovoltaic_Current_Outp brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. brick:Radon_Concentration_Sensor,,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon -brick:Rain_Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,Rain,Measures the duration of precipitation within some time frame -brick:Rain_Level_Sensor,,,,,,,brick:Sensor,Rain Level,Measures the amount of precipitation fallen +brick:Rain_Duration_Sensor,,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame +brick:Rain_Level_Sensor,,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen brick:Rated_Speed_Setpoint,,,,,,,,(deprecated),Sets rated speed brick:Reactive_Energy_Sensor,,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" @@ -697,7 +697,7 @@ brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the brick:Sensor_Failure_Alarm,,,,,,,,(deprecated), brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set brick:Short_Cycle_Alarm,,,,,,,,(deprecated),An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle -brick:Smoke_Alarm,,,,,,,,(deprecated),An alarm that indicates the off-normal conditions associated with smoke. +brick:Smoke_Alarm,,,,brick:Smoke,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with smoke. brick:Smoke_Detection_Alarm,,,brick:Smoke_Detection,,,,brick:Alarm,, brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun @@ -786,7 +786,7 @@ brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Sensor,U brick:Thermal_Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,,brick:Thermostat,,,,brick:Status,,Status of a thermostat brick:Time_Parameter,,,,,,,brick:Parameter,Time, -brick:Time_Setpoint,,,,,,,brick:Setpoint,Time, +brick:Time_Setpoint,,,,,,,brick:Time_Setpoint,, brick:Tint_Command,,,,,,,brick:Command,Tint,The target level of window tint. brick:Tint_Status,,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." brick:Tolerance_Parameter,,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. @@ -854,8 +854,8 @@ brick:Water_Temperature_Alarm,,,,brick:Water,,quantitykind:Temperature,brick:Ala brick:Water_Temperature_Sensor,,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water brick:Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water brick:Water_Usage_Sensor,,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" -brick:Wind_Direction_Sensor,,,,,,,brick:Sensor,Wind Direction,Measures the direction of wind in degrees relative to North -brick:Wind_Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,Wind,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Wind_Direction_Sensor,,,,brick:Wind,,,brick:Sensor,Direction,Measures the direction of wind in degrees relative to North +brick:Wind_Speed_Sensor,,,,brick:Wind,,quantitykind:Speed,brick:Sensor,,"Measured speed of wind, caused by air moving from high to low pressure" brick:Zone_Air_Conditioning_Mode_Status,,,,brick:Zone_Air,,brick:EnumerationKind-Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone brick:Zone_Air_Dewpoint_Sensor,,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air brick:Zone_Air_Humidity_Sensor,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air From a822c7b54662c04fe336270a6d353baac2a10650 Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 20:12:26 +0100 Subject: [PATCH 20/31] Define all point attributes [no ci] --- bricksrc/points.csv | 34 +++++++++++++++++----------------- 1 file changed, 17 insertions(+), 17 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 616ba8f5..c049eb07 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -68,7 +68,7 @@ brick:Chilled_Water_Flow_Sensor,,,,brick:Chilled_Water,,quantitykind:VolumeFlowR brick:Chilled_Water_Flow_Setpoint,,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water brick:Chilled_Water_Gauge_Pressure_Sensor,,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water -brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the chilled water system +brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,,brick:Command,Enable,Enables operation of the chilled water system brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water brick:Close_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. @@ -100,7 +100,7 @@ brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Cooling,brick:Discharge_Air,,q brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of cooling discharge air brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Cooling_Enable_Command,,,brick:Cooling,,,brick:EnumerationKind-Enable,brick:Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Enable_Command,,,brick:Cooling,,,,brick:Command,Enable,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." brick:Cooling_Mode_Status,,,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" brick:Cooling_Start_Stop_Status,,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling @@ -198,7 +198,7 @@ brick:Discharge_Air_Temperature_Step_Parameter,,,,brick:Discharge_Air,,quantityk brick:Discharge_Air_Velocity_Pressure_Sensor,,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water -brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,,brick:Command,Enable,Enables operation of the domestic hot water system brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water brick:Drive_Ready_Status,,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" @@ -226,13 +226,13 @@ brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed -brick:Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,,Commands that enable functionality -brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Enthalpy,Enables the use of differential enthalpy control -brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,brick:EnumerationKind-Enable,brick:Command,Temperature,Enables the use of differential temperature control -brick:Enable_Fixed_Enthalpy_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Fixed Enthalpy,Enables the use of fixed enthalpy control -brick:Enable_Fixed_Temperature_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Fixed Temperature,Enables the use of fixed temperature control -brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,brick:EnumerationKind-Enable,brick:Setpoint,Temperature,Enables hot water system when outside air temperature reaches the indicated value -brick:Enable_Status,,,,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if a system or piece of functionality has been enabled +brick:Enable_Command,,,,,,,brick:Command,Enable,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Enable,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Command,Enable,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Command,Enable Fixed,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Command,Enable Fixed,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable,Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,,brick:Status,Enable,Indicates if a system or piece of functionality has been enabled brick:Energy_Generation_Sensor,,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. brick:Energy_Sensor,,,,,,,brick:Sensor,Energy,Measures energy consumption brick:Energy_Usage_Sensor,,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time @@ -315,13 +315,13 @@ brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets freque brick:Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood -brick:Gain_Parameter,,,,,,,brick:Parameter,Gain, +brick:Gain_Parameter,,,,,,,brick:Gain_Parameter,, brick:Gas_Sensor,,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,brick:EnumerationKind-Enable,brick:Status,,Indicates if the heat exchanger system has been enabled +brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,,brick:Status,Enable,Indicates if the heat exchanger system has been enabled brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton @@ -330,7 +330,7 @@ brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Heating,brick:Discharge_Air,,q brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of heating discharge air brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Heating_Enable_Command,,,brick:Heating,,,brick:EnumerationKind-Enable,brick:Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Enable_Command,,,brick:Heating,,,,brick:Command,Enable,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." brick:Heating_Mode_Status,,,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" brick:Heating_Start_Stop_Status,,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating @@ -365,7 +365,7 @@ brick:Hot_Water_Flow_Sensor,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,bric brick:Hot_Water_Flow_Setpoint,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water brick:Hot_Water_Gauge_Pressure_Sensor,,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water brick:Hot_Water_Static_Pressure_Setpoint,,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air -brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of the hot water system +brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,,brick:Command,Enable,Enables operation of the hot water system brick:Hot_Water_Temperature_Setpoint,,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water brick:Hot_Water_Usage_Sensor,,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" brick:Humidification_Start_Stop_Status,,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, @@ -687,7 +687,7 @@ brick:Return_Air_Temperature_Sensor,,,,brick:Return_Air,,quantitykind:Temperatur brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air -brick:Run_Enable_Command,,,,,,brick:EnumerationKind-Enable,brick:Command,Run, +brick:Run_Enable_Command,,,,,,,brick:Command,Run Enable, brick:Run_Request_Status,,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment brick:Run_Status,,,,,,,brick:Status,Run, brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" @@ -765,7 +765,7 @@ brick:Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Te brick:Supply_Air_Temperature_Step_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, brick:Supply_Air_Velocity_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Switch_Status,,,brick:Switch,,,,brick:Status,,Status of a switch -brick:System_Enable_Command,,,brick:System,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a system +brick:System_Enable_Command,,,brick:System,,,,brick:Command,Enable,Enables operation of a system brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, @@ -830,7 +830,7 @@ brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,M brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated),Indicates the current operating mode of a vent brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. -brick:VFD_Enable_Command,,,brick:VFD,,,brick:EnumerationKind-Enable,brick:Command,,Enables operation of a variable frequency drive +brick:VFD_Enable_Command,,,brick:VFD,,,,brick:Command,Enable,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer From 7fbc959180fabaaabd8b7b3d71b2c072962f19db Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 20:18:34 +0100 Subject: [PATCH 21/31] Define all point attributes [no ci] --- bricksrc/points.csv | 52 ++++++++++++++++++++++----------------------- 1 file changed, 26 insertions(+), 26 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index c049eb07..000d4cce 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -68,7 +68,7 @@ brick:Chilled_Water_Flow_Sensor,,,,brick:Chilled_Water,,quantitykind:VolumeFlowR brick:Chilled_Water_Flow_Setpoint,,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water brick:Chilled_Water_Gauge_Pressure_Sensor,,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water -brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,,brick:Command,Enable,Enables operation of the chilled water system +brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,,brick:Enable_Command,,Enables operation of the chilled water system brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water brick:Close_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. @@ -100,7 +100,7 @@ brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Cooling,brick:Discharge_Air,,q brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of cooling discharge air brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Cooling_Enable_Command,,,brick:Cooling,,,,brick:Command,Enable,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Enable_Command,,,brick:Cooling,,,,brick:Enable_Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." brick:Cooling_Mode_Status,,,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" brick:Cooling_Start_Stop_Status,,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling @@ -155,13 +155,13 @@ brick:Differential_Temperature_Setpoint,,,,,brick:Differential,quantitykind:Temp brick:Direction_Command,,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon brick:Direction_Sensor,,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring brick:Direction_Status,,,,,,,brick:Status,Direction,Indicates which direction a device is operating in -brick:Disable_Command,,,,,,,brick:Command,Disable,Commands that disable functionality -brick:Disable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Disable,Disables the use of differential enthalpy control -brick:Disable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Command,Disable,Disables the use of differential temperature control -brick:Disable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Command,Disable Fixed,Disables the use of fixed enthalpy control -brick:Disable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Command,Disable Fixed,Disables the use of fixed temperature temperature -brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Disable,Disables hot water system when outside air temperature reaches the indicated value -brick:Disable_Status,,,,,,,brick:Status,Disable,Indicates if functionality has been disabled +brick:Disable_Command,,,,,,,brick:Disable_Command,,Commands that disable functionality +brick:Disable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Disable_Command,,Disables the use of differential enthalpy control +brick:Disable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Disable_Command,,Disables the use of differential temperature control +brick:Disable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Disable_Command,Fixed,Disables the use of fixed enthalpy control +brick:Disable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Disable_Command,Fixed,Disables the use of fixed temperature temperature +brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Disable_Setpoint,,Disables hot water system when outside air temperature reaches the indicated value +brick:Disable_Status,,,,,,,brick:Disable_Status,,Indicates if functionality has been disabled brick:Discharge_Air_Dewpoint_Sensor,,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air brick:Discharge_Air_Differential_Pressure_Sensor,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, brick:Discharge_Air_Differential_Pressure_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, @@ -198,7 +198,7 @@ brick:Discharge_Air_Temperature_Step_Parameter,,,,brick:Discharge_Air,,quantityk brick:Discharge_Air_Velocity_Pressure_Sensor,,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water -brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,,brick:Command,Enable,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the domestic hot water system brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water brick:Drive_Ready_Status,,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" @@ -226,13 +226,13 @@ brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed -brick:Enable_Command,,,,,,,brick:Command,Enable,Commands that enable functionality -brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Command,Enable,Enables the use of differential enthalpy control -brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Command,Enable,Enables the use of differential temperature control -brick:Enable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Command,Enable Fixed,Enables the use of fixed enthalpy control -brick:Enable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Command,Enable Fixed,Enables the use of fixed temperature control -brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable,Enables hot water system when outside air temperature reaches the indicated value -brick:Enable_Status,,,,,,,brick:Status,Enable,Indicates if a system or piece of functionality has been enabled +brick:Enable_Command,,,,,,,brick:Enable_Command,,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Enable_Command,,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Enable_Command,,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Enable_Command,Fixed,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Enable_Command,Fixed,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,,Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,,brick:Enable_Status,,Indicates if a system or piece of functionality has been enabled brick:Energy_Generation_Sensor,,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. brick:Energy_Sensor,,,,,,,brick:Sensor,Energy,Measures energy consumption brick:Energy_Usage_Sensor,,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time @@ -321,7 +321,7 @@ brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressu brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,,brick:Status,Enable,Indicates if the heat exchanger system has been enabled +brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton @@ -330,7 +330,7 @@ brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Heating,brick:Discharge_Air,,q brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of heating discharge air brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Heating_Enable_Command,,,brick:Heating,,,,brick:Command,Enable,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Enable_Command,,,brick:Heating,,,,brick:Enable_Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." brick:Heating_Mode_Status,,,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" brick:Heating_Start_Stop_Status,,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating @@ -365,7 +365,7 @@ brick:Hot_Water_Flow_Sensor,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,bric brick:Hot_Water_Flow_Setpoint,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water brick:Hot_Water_Gauge_Pressure_Sensor,,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water brick:Hot_Water_Static_Pressure_Setpoint,,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air -brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,,brick:Command,Enable,Enables operation of the hot water system +brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the hot water system brick:Hot_Water_Temperature_Setpoint,,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water brick:Hot_Water_Usage_Sensor,,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" brick:Humidification_Start_Stop_Status,,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, @@ -450,8 +450,8 @@ brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,(deprecated), brick:Low_Humidity_Alarm,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,,The lower bound of the outside air temperature lockout range -brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, -brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Enable, +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Enable_Sensor,, +brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,, brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. brick:Low_Supply_Air_Flow_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,, @@ -604,7 +604,7 @@ brick:Outside_Air_Humidity_Sensor,,,,brick:Outside_Air,,quantitykind:RelativeHum brick:Outside_Air_Humidity_Setpoint,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,, brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Lockout,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Sensor,Enable, +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Enable_Sensor,, brick:Outside_Air_Temperature_High_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Outside_Air_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air @@ -687,7 +687,7 @@ brick:Return_Air_Temperature_Sensor,,,,brick:Return_Air,,quantitykind:Temperatur brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air -brick:Run_Enable_Command,,,,,,,brick:Command,Run Enable, +brick:Run_Enable_Command,,,,,,,brick:Enable_Command,Run, brick:Run_Request_Status,,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment brick:Run_Status,,,,,,,brick:Status,Run, brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" @@ -765,7 +765,7 @@ brick:Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Te brick:Supply_Air_Temperature_Step_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, brick:Supply_Air_Velocity_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, brick:Switch_Status,,,brick:Switch,,,,brick:Status,,Status of a switch -brick:System_Enable_Command,,,brick:System,,,,brick:Command,Enable,Enables operation of a system +brick:System_Enable_Command,,,brick:System,,,,brick:Enable_Command,,Enables operation of a system brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, @@ -830,7 +830,7 @@ brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,M brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated),Indicates the current operating mode of a vent brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. -brick:VFD_Enable_Command,,,brick:VFD,,,,brick:Command,Enable,Enables operation of a variable frequency drive +brick:VFD_Enable_Command,,,brick:VFD,,,,brick:Enable_Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer From 5dbeed8096dfa4275361f527f2fcb75494c1b58f Mon Sep 17 00:00:00 2001 From: ektrah Date: Wed, 29 Oct 2025 20:25:56 +0100 Subject: [PATCH 22/31] Define all point attributes [no ci] --- bricksrc/points.csv | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 000d4cce..45578ed1 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -656,7 +656,7 @@ brick:Pump_Status,,,brick:Pump,,,,brick:Status,,Status of a pump brick:PV_Current_Output_Sensor,,,,,,,,(deprecated),See Photovoltaic_Current_Output_Sensor brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. -brick:Radon_Concentration_Sensor,,,,brick:Rn,,,brick:Sensor,Concentration,Measures the concentration of radioactivity due to radon +brick:Radon_Concentration_Sensor,,,,brick:Rn,,quantitykind:ActivityConcentration,brick:Sensor,,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen brick:Rated_Speed_Setpoint,,,,,,,,(deprecated),Sets rated speed From 4e9ff2a33ff49a9e3c94880d75f09becac5141cf Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 30 Oct 2025 13:29:58 +0100 Subject: [PATCH 23/31] Define all point attributes [no ci] --- bricksrc/points.csv | 124 ++++++++++++++++++++++---------------------- 1 file changed, 62 insertions(+), 62 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 45578ed1..a1c045b6 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -467,74 +467,74 @@ brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets lumina brick:Maintenance_Mode_Command,,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" brick:Maintenance_Required_Alarm,,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment brick:Manual_Auto_Status,,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation -brick:Max_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Max_Air_Temperature_Setpoint,brick:Maximum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for maximum air temperature -brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. -brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. -brick:Max_Discharge_Air_Temperature_Setpoint_Limit,brick:Maximum,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Max_Frequency_Command,brick:Maximum,,,,,quantitykind:Frequency,brick:Command,,Sets the maximum permitted frequency -brick:Max_Fresh_Air_Setpoint_Limit,brick:Maximum,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. -brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. -brick:Max_Limit,brick:Maximum,,,,,,brick:Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. -brick:Max_Load_Setpoint,brick:Maximum,,,,,,brick:Setpoint,Load, -brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. -brick:Max_Outside_Air_Flow_Setpoint_Limit,brick:Maximum,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. -brick:Max_Position_Setpoint_Limit,brick:Maximum,,,,,,brick:Setpoint_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. -brick:Max_Speed_Setpoint_Limit,brick:Maximum,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. -brick:Max_Static_Pressure_Setpoint_Limit,brick:Maximum,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Maximum,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. -brick:Max_Supply_Air_Temperature_Setpoint_Limit,brick:Maximum,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Max_Temperature_Setpoint_Limit,brick:Maximum,,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. -brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Maximum,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. -brick:Max_Water_Level_Alarm,brick:Maximum,,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the maximum water level was reached -brick:Max_Water_Temperature_Setpoint,brick:Maximum,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for max water temperature +brick:Max_Air_Flow_Setpoint_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Max_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for maximum air temperature +brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Max_Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Max_Frequency_Command,,,,,,quantitykind:Frequency,brick:Max_Command,,Sets the maximum permitted frequency +brick:Max_Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Max_Limit,,,,,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. +brick:Max_Load_Setpoint,,,,,,,brick:Max_Setpoint,Load, +brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Outside_Air_Flow_Setpoint_Limit,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Max_Position_Setpoint_Limit,,,,,,,brick:Max_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. +brick:Max_Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Max_Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Max_Temperature_Setpoint_Limit,,,,,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. +brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Water_Level_Alarm,,,,brick:Water,,,brick:Max_Alarm,Level,Alarm indicating that the maximum water level was reached +brick:Max_Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for max water temperature brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between sections of a medium temperature hot water system brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Methane_Level_Sensor,,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air -brick:Min_Air_Flow_Setpoint_Limit,brick:Minimum,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Min_Air_Temperature_Setpoint,brick:Minimum,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Setpoint for minimum air temperature -brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. -brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. -brick:Min_Discharge_Air_Temperature_Setpoint_Limit,brick:Minimum,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Min_Frequency_Command,brick:Minimum,,,,,quantitykind:Frequency,brick:Command,, -brick:Min_Fresh_Air_Setpoint_Limit,brick:Minimum,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. -brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. -brick:Min_Limit,brick:Minimum,,,,,,brick:Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. -brick:Min_Load_Setpoint,brick:Minimum,,,,,,brick:Setpoint,Load, -brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. -brick:Min_Outside_Air_Flow_Setpoint_Limit,brick:Minimum,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. -brick:Min_Position_Setpoint_Limit,brick:Minimum,,,,,,brick:Setpoint_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. -brick:Min_Speed_Setpoint_Limit,brick:Minimum,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. -brick:Min_Static_Pressure_Setpoint_Limit,brick:Minimum,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,brick:Minimum,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. -brick:Min_Supply_Air_Temperature_Setpoint_Limit,brick:Minimum,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Min_Temperature_Setpoint_Limit,brick:Minimum,,,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. -brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Minimum,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. -brick:Min_Water_Level_Alarm,brick:Minimum,,,brick:Water,,,brick:Alarm,Level,Alarm indicating that the minimum water level was reached -brick:Min_Water_Temperature_Setpoint,brick:Minimum,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Setpoint for min water temperature +brick:Min_Air_Flow_Setpoint_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Min_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for minimum air temperature +brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Min_Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Min_Frequency_Command,,,,,,quantitykind:Frequency,,, +brick:Min_Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Min_Limit,,,,,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. +brick:Min_Load_Setpoint,,,,,,,brick:Min_Setpoint,Load, +brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Outside_Air_Flow_Setpoint_Limit,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Min_Position_Setpoint_Limit,,,,,,,brick:Min_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. +brick:Min_Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Min_Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Min_Temperature_Setpoint_Limit,,,,,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. +brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Water_Level_Alarm,,,,brick:Water,,,brick:Min_Alarm,Level,Alarm indicating that the minimum water level was reached +brick:Min_Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for min water temperature brick:Mixed_Air_Flow_Sensor,,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air brick:Mixed_Air_Humidity_Sensor,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air brick:Mixed_Air_Humidity_Setpoint,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air From 5231543e668f98a3f4658076368e3ff362449650 Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 30 Oct 2025 14:18:29 +0100 Subject: [PATCH 24/31] Define all point attributes [no ci] --- bricksrc/points.csv | 58 ++++++++++++++++++++++----------------------- 1 file changed, 29 insertions(+), 29 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index a1c045b6..f39871a9 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -222,8 +222,8 @@ brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,bric brick:Emergency_Alarm,,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active -brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,brick:High,,brick:Emergency_Power_Off_System,,,quantitykind:Temperature,brick:Status,Activated By, -brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,Activated By Leak Detection System, +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,(deprecated), brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed brick:Enable_Command,,,,,,,brick:Enable_Command,,Commands that enable functionality @@ -340,18 +340,18 @@ brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating brick:Heating_Temperature_Setpoint,,,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating brick:Heating_Thermal_Power_Sensor,,,brick:Heating,,,quantitykind:Power,brick:Sensor,Thermal, brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The heating setpoint for a specific zone in a building. -brick:High_Air_Flow_Alarm,brick:High,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is higher than normal. -brick:High_CO2_Alarm,brick:High,,,brick:CO2,,,brick:Alarm,,A device that indicates high concentration of carbon dioxide. -brick:High_Discharge_Air_Temperature_Alarm,brick:High,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that discharge air temperature is too high +brick:High_Air_Flow_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. +brick:High_CO2_Alarm,,,,brick:CO2,,,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. +brick:High_Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that discharge air temperature is too high brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. -brick:High_Humidity_Alarm,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates high concentration of water vapor in the air. -brick:High_Humidity_Alarm_Parameter,brick:High,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm -brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:High,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,,The upper bound of the outside air temperature lockout range -brick:High_Return_Air_Temperature_Alarm,brick:High,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too high +brick:High_Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,,The upper bound of the outside air temperature lockout range +brick:High_Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. -brick:High_Supply_Air_Temperature_Alarm,brick:High,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, -brick:High_Temperature_Alarm,brick:High,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates high temperature. -brick:High_Temperature_Alarm_Parameter,brick:High,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm +brick:High_Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, +brick:High_Temperature_Alarm,,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. +brick:High_Temperature_Alarm_Parameter,,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm brick:Hold_Status,,,,,,,,(deprecated), brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, @@ -442,23 +442,23 @@ brick:Load_Shed_Status,,,brick:Load_Shed,,,,brick:Status,,Indicates if a load sh brick:Locally_On_Off_Status,,,,,,,,(deprecated), brick:Lockout_Status,,,brick:Lockout,,,,brick:Status,,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" brick:Lockout_Temperature_Differential_Parameter,,,brick:Lockout,,brick:Differential,quantitykind:Temperature,brick:Parameter,, -brick:Low_Air_Flow_Alarm,brick:Low,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the air flow is lower than normal. -brick:Low_Battery_Alarm,brick:Low,,brick:Battery,,,,brick:Alarm,,An alarm that indicates the battery is low. -brick:Low_Discharge_Air_Flow_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm that indicates that the discharge air flow is lower than normal. -brick:Low_Discharge_Air_Temperature_Alarm,brick:Low,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,, +brick:Low_Air_Flow_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. +brick:Low_Battery_Alarm,,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. +brick:Low_Discharge_Air_Flow_Alarm,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. +brick:Low_Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Alarm,, brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,(deprecated), -brick:Low_Humidity_Alarm,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates low concentration of water vapor in the air. -brick:Low_Humidity_Alarm_Parameter,brick:Low,,,,,quantitykind:RelativeHumidity,brick:Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm -brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,brick:Low,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,,The lower bound of the outside air temperature lockout range -brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,brick:Low,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Enable_Sensor,, -brick:Low_Outside_Air_Temperature_Enable_Setpoint,brick:Low,,,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,, -brick:Low_Return_Air_Temperature_Alarm,brick:Low,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates that return air temperature is too low +brick:Low_Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,,(deprecated), +brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,,(deprecated), +brick:Low_Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. -brick:Low_Supply_Air_Flow_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Alarm,, -brick:Low_Supply_Air_Temperature_Alarm,brick:Low,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,, -brick:Low_Temperature_Alarm,brick:Low,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates low temperature. -brick:Low_Temperature_Alarm_Parameter,brick:Low,,,,,quantitykind:Temperature,brick:Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm -brick:Low_Voltage_Alarm,brick:Low,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is lower than its normal state. +brick:Low_Supply_Air_Flow_Alarm,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,, +brick:Low_Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Alarm,, +brick:Low_Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. +brick:Low_Temperature_Alarm_Parameter,,,,,,quantitykind:Temperature,brick:Low_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm +brick:Low_Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Low_Alarm,,An alarm that indicates the voltage is lower than its normal state. brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,brick:Lowest,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time brick:Luminance_Alarm,,,,,,quantitykind:Luminance,brick:Alarm,, brick:Luminance_Command,,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system @@ -511,7 +511,7 @@ brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Discha brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. brick:Min_Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Min_Frequency_Command,,,,,,quantitykind:Frequency,,, +brick:Min_Frequency_Command,,,,,,quantitykind:Frequency,brick:Min_Command,, brick:Min_Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. @@ -604,7 +604,7 @@ brick:Outside_Air_Humidity_Sensor,,,,brick:Outside_Air,,quantitykind:RelativeHum brick:Outside_Air_Humidity_Setpoint,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,, brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Lockout,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Enable_Sensor,, +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,,(deprecated), brick:Outside_Air_Temperature_High_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Outside_Air_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air From 94581242d27f610109948c78605d2f0178dda7c2 Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 30 Oct 2025 14:24:24 +0100 Subject: [PATCH 25/31] Define all point attributes [no ci] --- bricksrc/points.csv | 1734 +++++++++++++++++++++---------------------- 1 file changed, 867 insertions(+), 867 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index f39871a9..d89ccbf4 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,867 +1,867 @@ -@id,brick:isAggregated,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition -brick:Absolute_Humidity_Sensor,,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity -brick:Acceleration_Time_Setpoint,,,brick:Acceleration,,,,brick:Time_Setpoint,, -brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" -brick:Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of some value -brick:Air_Alarm,,,,brick:Air,,,brick:Alarm,, -brick:Air_Differential_Pressure_Sensor,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air -brick:Air_Differential_Pressure_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit -brick:Air_Enthalpy_Sensor,,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air -brick:Air_Flow_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. -brick:Air_Flow_Deadband_Setpoint,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow -brick:Air_Flow_Demand_Setpoint,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of air flow required for a process -brick:Air_Flow_Loss_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. -brick:Air_Flow_Sensor,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air -brick:Air_Flow_Setpoint,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow -brick:Air_Flow_Setpoint_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Air_Grains_Sensor,,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air -brick:Air_Pressure_Sensor,,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. -brick:Air_Pressure_Setpoint,,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, -brick:Air_Quality_Sensor,,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality -brick:Air_Static_Pressure_Sensor,,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." -brick:Air_Static_Pressure_Step_Parameter,,,,brick:Air,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Air_Temperature_Alarm,,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. -brick:Air_Temperature_Integral_Time_Parameter,,,,brick:Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air -brick:Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air -brick:Air_Temperature_Setpoint_Limit,,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. -brick:Air_Temperature_Step_Parameter,,,,brick:Air,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Air_Velocity_Pressure_Sensor,,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. -brick:Air_Wet_Bulb_Temperature_Sensor,,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, -brick:Alarm,,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action -brick:Alarm_Delay_Parameter,,,,,,,brick:Alarm_Delay_Parameter,,A parameter determining how long to delay an alarm after sufficient conditions have been met -brick:Alarm_Sensitivity_Parameter,,,,,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate an alarm. -brick:Ammonia_Sensor,,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air -brick:Angle_Sensor,,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon -brick:Automatic_Mode_Command,,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" -brick:Availability_Status,,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" -brick:Average_Cooling_Demand_Sensor,brick:Average,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the average power consumed by a cooling process as the amount of power consumed over some interval -brick:Average_Discharge_Air_Flow_Sensor,brick:Average,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of discharge air over some interval -brick:Average_Exhaust_Air_Static_Pressure_Sensor,brick:Average,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time -brick:Average_Heating_Demand_Sensor,brick:Average,,brick:Heating,,,,brick:Demand_Sensor,,Measures the average power consumed by a heating process as the amount of power consumed over some interval -brick:Average_Supply_Air_Flow_Sensor,brick:Average,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,The computed average flow of supply air over some interval -brick:Average_Zone_Air_Temperature_Sensor,brick:Average,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,"The computed average temperature of air in a zone, over some period of time" -brick:Battery_Voltage_Sensor,,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery -brick:Boiler_Command,,,brick:Boiler,,,,brick:Command,,A command to control a boiler -brick:Box_Mode_Command,,,,,,,,(deprecated), -brick:Building_Air_Humidity_Setpoint,,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building -brick:Building_Air_Static_Pressure_Sensor,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building -brick:Building_Air_Static_Pressure_Setpoint,,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building -brick:Bypass_Air_Flow_Sensor,,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air -brick:Bypass_Air_Humidity_Setpoint,,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air -brick:Bypass_Command,,,,,,,,(deprecated), -brick:Bypass_Water_Flow_Sensor,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water -brick:Bypass_Water_Flow_Setpoint,,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water -brick:Capacity_Sensor,,,,,,quantitykind:Capacity,brick:Sensor,, -brick:Change_Filter_Alarm,,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed -brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water -brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, -brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,, -brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Chilled_Water_Differential_Pressure_Sensor,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve -brick:Chilled_Water_Differential_Pressure_Setpoint,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water -brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, -brick:Chilled_Water_Differential_Temperature_Sensor,,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device -brick:Chilled_Water_Flow_Sensor,,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit -brick:Chilled_Water_Flow_Setpoint,,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water -brick:Chilled_Water_Gauge_Pressure_Sensor,,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water -brick:Chilled_Water_Static_Pressure_Setpoint,,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water -brick:Chilled_Water_System_Enable_Command,,,brick:Chilled_Water_System,,,,brick:Enable_Command,,Enables operation of the chilled water system -brick:Chilled_Water_Temperature_Sensor,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water -brick:Chilled_Water_Temperature_Setpoint,,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water -brick:Close_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. -brick:CO_Differential_Sensor,,,,brick:CO,brick:Differential,,brick:Sensor,, -brick:CO_Level_Sensor,,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO -brick:CO_Sensor,,,,brick:CO,,,brick:Sensor,,Measures properties of CO -brick:CO2_Alarm,,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. -brick:CO2_Alarm_Sensitivity_Parameter,,,,brick:CO2,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a CO2 alarm. -brick:CO2_Differential_Sensor,,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air -brick:CO2_Level_Sensor,,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air -brick:CO2_Sensor,,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air -brick:CO2_Setpoint,,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 -brick:Coldest_Zone_Air_Temperature_Sensor,brick:Coldest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' -brick:Collection_Basin_Water_Level_Alarm,,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" -brick:Collection_Basin_Water_Level_Sensor,,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" -brick:Collection_Basin_Water_Temperature_Sensor,,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" -brick:Command,,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. -brick:Communication_Loss_Alarm,,,,,,brick:EnumerationKind-CommunicationState,brick:Loss_Alarm,,An alarm that indicates a loss of communication e.g. with a device or controller -brick:Condensate_Leak_Alarm,,,,brick:Condensate,,,brick:Leak_Alarm,,An alarm that indicates a leak of condensate from a cooling system -brick:Condenser_Water_Flow_Sensor,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water -brick:Condenser_Water_Flow_Setpoint,,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Condenser_Water_Temperature_Sensor,,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water -brick:Conductivity_Sensor,,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance -brick:Contact_Sensor,,,,,,,,(deprecated),"Senses or detects contact, such as for determining if a door is closed." -brick:Cooling_Command,,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) -brick:Cooling_Demand_Sensor,,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton -brick:Cooling_Demand_Setpoint,,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling -brick:Cooling_Discharge_Air_Flow_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling -brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of cooling discharge air -brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Cooling_Enable_Command,,,brick:Cooling,,,,brick:Enable_Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." -brick:Cooling_Mode_Status,,,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" -brick:Cooling_Start_Stop_Status,,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, -brick:Cooling_Supply_Air_Flow_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling -brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for cooling -brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Cooling_Temperature_Setpoint,,,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling -brick:Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The cooling setpoint for a specific zone in a building. -brick:Core_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. -brick:Core_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." -brick:Current_Imbalance_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system -brick:Current_Limit,,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. -brick:Current_Output_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device -brick:Current_Ratio_Setpoint,,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer -brick:Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor -brick:Curtailment_Override_Command,,,,,,,,(deprecated), -brick:Cycle_Alarm,,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with HVAC cycles -brick:Damper_Command,,,brick:Damper,,,,brick:Command,,Controls properties of dampers -brick:Damper_Position_Command,,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper -brick:Damper_Position_Sensor,,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open -brick:Damper_Position_Setpoint,,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper -brick:Damper_Position_Status,,,brick:Damper,,,,brick:Status,Position, -brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated),Measures the voltage across a DC bus -brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband -brick:Deceleration_Time_Setpoint,,,brick:Deceleration,,,,brick:Time_Setpoint,, -brick:Dehumidification_Start_Stop_Status,,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, -brick:Dehumidify_Command,,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" -brick:Deionized_Water_Alarm,,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. -brick:Deionized_Water_Conductivity_Sensor,,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water -brick:Deionized_Water_Level_Sensor,,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container -brick:Delay_Parameter,,,,,,,brick:Delay_Parameter,,A parameter determining how long to delay a subsequent action to take place after a received signal -brick:Demand_Sensor,,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton -brick:Demand_Setpoint,,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process -brick:Derivative_Gain_Parameter,,,,,,,brick:Derivative_Gain_Parameter,, -brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, -brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor -brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point -brick:Differential_Air_Temperature_Setpoint,,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit -brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure -brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, -brick:Differential_Pressure_Proportional_Band_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Differential_Pressure_Sensor,,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures -brick:Differential_Pressure_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure -brick:Differential_Pressure_Setpoint_Limit,,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. -brick:Differential_Pressure_Step_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, -brick:Differential_Setpoint,,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements -brick:Differential_Speed_Sensor,,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, -brick:Differential_Speed_Setpoint,,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed -brick:Differential_Temperature_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements -brick:Direction_Command,,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon -brick:Direction_Sensor,,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring -brick:Direction_Status,,,,,,,brick:Status,Direction,Indicates which direction a device is operating in -brick:Disable_Command,,,,,,,brick:Disable_Command,,Commands that disable functionality -brick:Disable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Disable_Command,,Disables the use of differential enthalpy control -brick:Disable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Disable_Command,,Disables the use of differential temperature control -brick:Disable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Disable_Command,Fixed,Disables the use of fixed enthalpy control -brick:Disable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Disable_Command,Fixed,Disables the use of fixed temperature temperature -brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Disable_Setpoint,,Disables hot water system when outside air temperature reaches the indicated value -brick:Disable_Status,,,,,,,brick:Disable_Status,,Indicates if functionality has been disabled -brick:Discharge_Air_Dewpoint_Sensor,,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air -brick:Discharge_Air_Differential_Pressure_Sensor,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, -brick:Discharge_Air_Differential_Pressure_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Discharge_Air_Duct_Pressure_Status,,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds -brick:Discharge_Air_Flow_Demand_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of discharge air flow required for a process -brick:Discharge_Air_Flow_High_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, -brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, -brick:Discharge_Air_Flow_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies -brick:Discharge_Air_Flow_Sensor,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air -brick:Discharge_Air_Flow_Setpoint,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow -brick:Discharge_Air_Humidity_Sensor,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air -brick:Discharge_Air_Humidity_Setpoint,,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air -brick:Discharge_Air_Integral_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Integral_Gain_Parameter,, -brick:Discharge_Air_Proportional_Gain_Parameter,,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, -brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Smoke_Detection,brick:Discharge_Air,,,brick:Alarm,, -brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air -brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, -brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Discharge_Air_Static_Pressure_Sensor,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system -brick:Discharge_Air_Static_Pressure_Setpoint,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air -brick:Discharge_Air_Static_Pressure_Step_Parameter,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. -brick:Discharge_Air_Temperature_Cooling_Setpoint,,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for cooling -brick:Discharge_Air_Temperature_Deadband_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air -brick:Discharge_Air_Temperature_Heating_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for heating -brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, -brick:Discharge_Air_Temperature_Sensor,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air -brick:Discharge_Air_Temperature_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air -brick:Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Discharge_Air_Temperature_Step_Parameter,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Discharge_Air_Velocity_Pressure_Sensor,,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, -brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. -brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water -brick:Domestic_Hot_Water_System_Enable_Command,,,brick:Domestic_Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the domestic hot water system -brick:Domestic_Hot_Water_Temperature_Sensor,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water -brick:Drive_Ready_Status,,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" -brick:Duct_Air_Static_Pressure_Setpoint,,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, -brick:Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,,,,(deprecated), -brick:Effective_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, -brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. -brick:Effective_Discharge_Air_Temperature_Setpoint,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, -brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective heating setpoint for a specific zone in a building. -brick:Effective_Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, -brick:Effective_Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, -brick:Effective_Supply_Air_Temperature_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, -brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width -brick:Electric_Energy_Sensor,,,,,,,brick:Sensor,Electric Energy, -brick:Electric_Power_Sensor,,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed -brick:Electrical_Energy_Usage_Sensor,,,,,,,brick:Sensor,Electrical Energy Usage,A sensor that records the quantity of electrical energy consumed in a given period -brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. -brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." -brick:Emergency_Air_Flow_System_Status,,,brick:Emergency_Air_Flow_System,,,,brick:Status,, -brick:Emergency_Alarm,,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems -brick:Emergency_Generator_Alarm,,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator -brick:Emergency_Generator_Status,,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active -brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,(deprecated), -brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,(deprecated), -brick:Emergency_Power_Off_System_Status,,,brick:Emergency_Power_Off_System,,,,brick:Status,, -brick:Emergency_Push_Button_Status,,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed -brick:Enable_Command,,,,,,,brick:Enable_Command,,Commands that enable functionality -brick:Enable_Differential_Enthalpy_Command,,,,,brick:Differential,quantitykind:Enthalpy,brick:Enable_Command,,Enables the use of differential enthalpy control -brick:Enable_Differential_Temperature_Command,,,,,brick:Differential,quantitykind:Temperature,brick:Enable_Command,,Enables the use of differential temperature control -brick:Enable_Fixed_Enthalpy_Command,,,,,,quantitykind:Enthalpy,brick:Enable_Command,Fixed,Enables the use of fixed enthalpy control -brick:Enable_Fixed_Temperature_Command,,,,,,quantitykind:Temperature,brick:Enable_Command,Fixed,Enables the use of fixed temperature control -brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,,Enables hot water system when outside air temperature reaches the indicated value -brick:Enable_Status,,,,,,,brick:Enable_Status,,Indicates if a system or piece of functionality has been enabled -brick:Energy_Generation_Sensor,,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. -brick:Energy_Sensor,,,,,,,brick:Sensor,Energy,Measures energy consumption -brick:Energy_Usage_Sensor,,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time -brick:Entering_Chilled_Water_Flow_Sensor,,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water -brick:Entering_Chilled_Water_Flow_Setpoint,,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water -brick:Entering_Chilled_Water_Temperature_Sensor,,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower -brick:Entering_Chilled_Water_Temperature_Setpoint,,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water -brick:Entering_Condenser_Water_Flow_Sensor,,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water -brick:Entering_Condenser_Water_Temperature_Sensor,,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water -brick:Entering_Condenser_Water_Temperature_Setpoint,,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water -brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, -brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Entering_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water enteringed to a hot water system -brick:Entering_Hot_Water_Flow_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water -brick:Entering_Hot_Water_Flow_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water -brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Entering_Hot_Water_Temperature_Sensor,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system -brick:Entering_Hot_Water_Temperature_Setpoint,,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water -brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water entering a hot water system -brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water -brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Entering_Water_Flow_Sensor,,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system -brick:Entering_Water_Flow_Setpoint,,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water -brick:Entering_Water_Pressure_Sensor,,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. -brick:Entering_Water_Temperature_Alarm,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. -brick:Entering_Water_Temperature_Deadband_Setpoint,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water -brick:Entering_Water_Temperature_Integral_Time_Parameter,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Entering_Water_Temperature_Sensor,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water -brick:Entering_Water_Temperature_Setpoint,,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water -brick:Enthalpy_Sensor,,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance -brick:Enthalpy_Setpoint,,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy -brick:Even_Month_Status,,,,,,,,(deprecated), -brick:Exhaust_Air_Dewpoint_Sensor,,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air -brick:Exhaust_Air_Differential_Pressure_Sensor,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building -brick:Exhaust_Air_Differential_Pressure_Setpoint,,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit -brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, -brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, -brick:Exhaust_Air_Flow_Sensor,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air -brick:Exhaust_Air_Flow_Setpoint,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate -brick:Exhaust_Air_Humidity_Sensor,,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air -brick:Exhaust_Air_Humidity_Setpoint,,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air -brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow -brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, -brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, -brick:Exhaust_Air_Stack_Flow_Sensor,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack -brick:Exhaust_Air_Stack_Flow_Setpoint,,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate -brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Exhaust_Air_Static_Pressure_Sensor,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system -brick:Exhaust_Air_Static_Pressure_Setpoint,,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air -brick:Exhaust_Air_Temperature_Sensor,,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air -brick:Exhaust_Air_Velocity_Pressure_Sensor,,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, -brick:Failure_Alarm,,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" -brick:Fan_Command,,,brick:Fan,,,,brick:Command,,Controls properties of fans -brick:Fan_On_Off_Status,,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, -brick:Fan_Speed_Command,,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans -brick:Fan_Status,,,brick:Fan,,,,brick:Status,,Indicates properties of fans -brick:Fault_Reset_Command,,,,,,,brick:Reset_Command,Fault,Clears a fault status -brick:Fault_Status,,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" -brick:Filter_Air_Differential_Pressure_Sensor,,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. -brick:Filter_Differential_Pressure_Sensor,,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter -brick:Filter_Reset_Command,,,brick:Filter,,,,brick:Reset_Command,, -brick:Filter_Status,,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced -brick:Filter_Water_Differential_Pressure_Sensor,,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. -brick:Fire_Sensor,,,,brick:Fire,,,brick:Sensor,,Measures the presence of fire -brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance -brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow -brick:Formaldehyde_Level_Sensor,,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen -brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) -brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" -brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency -brick:Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Frost_Sensor,,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost -brick:Fume_Hood_Air_Flow_Sensor,,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood -brick:Gain_Parameter,,,,,,,brick:Gain_Parameter,, -brick:Gas_Sensor,,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) -brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure -brick:Generation_Sensor,,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. -brick:Hail_Sensor,,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential -brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, -brick:Heat_Exchanger_System_Enable_Status,,,brick:Heat_Exchanger_System,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. -brick:Heating_Command,,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) -brick:Heating_Demand_Sensor,,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton -brick:Heating_Demand_Setpoint,,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating -brick:Heating_Discharge_Air_Flow_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating -brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of heating discharge air -brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Heating_Enable_Command,,,brick:Heating,,,,brick:Enable_Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." -brick:Heating_Mode_Status,,,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" -brick:Heating_Start_Stop_Status,,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, -brick:Heating_Supply_Air_Flow_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating -brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for heating -brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Heating_Temperature_Setpoint,,,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating -brick:Heating_Thermal_Power_Sensor,,,brick:Heating,,,quantitykind:Power,brick:Sensor,Thermal, -brick:Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The heating setpoint for a specific zone in a building. -brick:High_Air_Flow_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. -brick:High_CO2_Alarm,,,,brick:CO2,,,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. -brick:High_Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. -brick:High_Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. -brick:High_Humidity_Alarm_Parameter,,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm -brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,,The upper bound of the outside air temperature lockout range -brick:High_Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high -brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. -brick:High_Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, -brick:High_Temperature_Alarm,,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. -brick:High_Temperature_Alarm_Parameter,,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm -brick:Hold_Status,,,,,,,,(deprecated), -brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water -brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, -brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, -brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Hot_Water_Differential_Pressure_Sensor,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve -brick:Hot_Water_Differential_Pressure_Setpoint,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water -brick:Hot_Water_Differential_Temperature_Sensor,,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device -brick:Hot_Water_Flow_Sensor,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit -brick:Hot_Water_Flow_Setpoint,,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water -brick:Hot_Water_Gauge_Pressure_Sensor,,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water -brick:Hot_Water_Static_Pressure_Setpoint,,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air -brick:Hot_Water_System_Enable_Command,,,brick:Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the hot water system -brick:Hot_Water_Temperature_Setpoint,,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water -brick:Hot_Water_Usage_Sensor,,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" -brick:Humidification_Start_Stop_Status,,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, -brick:Humidifier_Fault_Status,,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier -brick:Humidify_Command,,,,,,,brick:Command,Humidify, -brick:Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. -brick:Humidity_Deadband_Setpoint,,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity -brick:Humidity_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points -brick:Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air -brick:Humidity_Setpoint,,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity -brick:Humidity_Tolerance_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. -brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,,brick:Ice_Tank,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving an ice tank -brick:Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" -brick:Illuminance_Setpoint,,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. -brick:Imbalance_Sensor,,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system -brick:Inside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. -brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. -brick:Intake_Air_Temperature_Sensor,,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside -brick:Integral_Gain_Parameter,,,,,,,brick:Integral_Gain_Parameter,, -brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,,,(deprecated),Indicates the last fault code that occurred -brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation -brick:Lead_Lag_Status,,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled -brick:Lead_On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" -brick:Leak_Alarm,,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids -brick:Leaving_Chilled_Water_Flow_Sensor,,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water -brick:Leaving_Chilled_Water_Flow_Setpoint,,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water -brick:Leaving_Chilled_Water_Temperature_Sensor,,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller -brick:Leaving_Chilled_Water_Temperature_Setpoint,,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water -brick:Leaving_Condenser_Water_Flow_Sensor,,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water -brick:Leaving_Condenser_Water_Temperature_Sensor,,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water -brick:Leaving_Condenser_Water_Temperature_Setpoint,,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water -brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of domestic water supplied by a hot water system -brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leavinging part of domestic hot water -brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Leaving_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water supplied by a hot water system -brick:Leaving_Hot_Water_Flow_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water -brick:Leaving_Hot_Water_Flow_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water -brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Leaving_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system -brick:Leaving_Hot_Water_Temperature_Setpoint,,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water supplied by a hot water system -brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water -brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, -brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, -brick:Leaving_Water_Flow_Sensor,,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system -brick:Leaving_Water_Flow_Setpoint,,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water -brick:Leaving_Water_Pressure_Sensor,,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. -brick:Leaving_Water_Temperature_Alarm,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. -brick:Leaving_Water_Temperature_Deadband_Setpoint,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water -brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, -brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Leaving_Water_Temperature_Sensor,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system -brick:Leaving_Water_Temperature_Setpoint,,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water -brick:Level_Command,,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. -brick:Level_Status,,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. -brick:Lighting_Correlated_Color_Temperature_Command,,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. -brick:Lighting_Correlated_Color_Temperature_Sensor,,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. -brick:Lighting_Level_Command,,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. -brick:Limit,,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point -brick:Liquid_Detection_Alarm,,,brick:Liquid_Detection,,,,brick:Alarm,, -brick:Load_Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load -brick:Load_Parameter,,,,,,,brick:Parameter,Load, -brick:Load_Setpoint,,,,,,,brick:Setpoint,Load, -brick:Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,,Controls load shedding behavior provided by a control system -brick:Load_Shed_Differential_Pressure_Setpoint,,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Load_Shed_Setpoint,,,brick:Load_Shed,,,,brick:Setpoint,, -brick:Load_Shed_Status,,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,,,,(deprecated), -brick:Lockout_Status,,,brick:Lockout,,,,brick:Status,,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" -brick:Lockout_Temperature_Differential_Parameter,,,brick:Lockout,,brick:Differential,quantitykind:Temperature,brick:Parameter,, -brick:Low_Air_Flow_Alarm,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. -brick:Low_Battery_Alarm,,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. -brick:Low_Discharge_Air_Flow_Alarm,,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. -brick:Low_Discharge_Air_Temperature_Alarm,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Alarm,, -brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,(deprecated), -brick:Low_Humidity_Alarm,,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. -brick:Low_Humidity_Alarm_Parameter,,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm -brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,,The lower bound of the outside air temperature lockout range -brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,,(deprecated), -brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,,(deprecated), -brick:Low_Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. -brick:Low_Supply_Air_Flow_Alarm,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,, -brick:Low_Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Alarm,, -brick:Low_Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. -brick:Low_Temperature_Alarm_Parameter,,,,,,quantitykind:Temperature,brick:Low_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm -brick:Low_Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Low_Alarm,,An alarm that indicates the voltage is lower than its normal state. -brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,brick:Lowest,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time -brick:Luminance_Alarm,,,,,,quantitykind:Luminance,brick:Alarm,, -brick:Luminance_Command,,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system -brick:Luminance_Sensor,,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction -brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance -brick:Maintenance_Mode_Command,,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" -brick:Maintenance_Required_Alarm,,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment -brick:Manual_Auto_Status,,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation -brick:Max_Air_Flow_Setpoint_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Max_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for maximum air temperature -brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. -brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. -brick:Max_Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Max_Frequency_Command,,,,,,quantitykind:Frequency,brick:Max_Command,,Sets the maximum permitted frequency -brick:Max_Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. -brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. -brick:Max_Limit,,,,,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. -brick:Max_Load_Setpoint,,,,,,,brick:Max_Setpoint,Load, -brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. -brick:Max_Outside_Air_Flow_Setpoint_Limit,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. -brick:Max_Position_Setpoint_Limit,,,,,,,brick:Max_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. -brick:Max_Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. -brick:Max_Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. -brick:Max_Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Max_Temperature_Setpoint_Limit,,,,,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. -brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. -brick:Max_Water_Level_Alarm,,,,brick:Water,,,brick:Max_Alarm,Level,Alarm indicating that the maximum water level was reached -brick:Max_Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for max water temperature -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between sections of a medium temperature hot water system -brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Methane_Level_Sensor,,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air -brick:Min_Air_Flow_Setpoint_Limit,,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. -brick:Min_Air_Temperature_Setpoint,,,,brick:Air,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for minimum air temperature -brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. -brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. -brick:Min_Discharge_Air_Temperature_Setpoint_Limit,,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. -brick:Min_Frequency_Command,,,,,,quantitykind:Frequency,brick:Min_Command,, -brick:Min_Fresh_Air_Setpoint_Limit,,,,brick:Fresh_Air,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. -brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. -brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. -brick:Min_Limit,,,,,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. -brick:Min_Load_Setpoint,,,,,,,brick:Min_Setpoint,Load, -brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. -brick:Min_Outside_Air_Flow_Setpoint_Limit,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. -brick:Min_Position_Setpoint_Limit,,,,,,,brick:Min_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. -brick:Min_Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. -brick:Min_Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. -brick:Min_Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Min_Temperature_Setpoint_Limit,,,,,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. -brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. -brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. -brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. -brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. -brick:Min_Water_Level_Alarm,,,,brick:Water,,,brick:Min_Alarm,Level,Alarm indicating that the minimum water level was reached -brick:Min_Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for min water temperature -brick:Mixed_Air_Flow_Sensor,,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air -brick:Mixed_Air_Humidity_Sensor,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air -brick:Mixed_Air_Humidity_Setpoint,,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air -brick:Mixed_Air_Temperature_Sensor,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air -brick:Mixed_Air_Temperature_Setpoint,,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air -brick:Mode_Command,,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the operating mode of a device or controller -brick:Mode_Status,,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" -brick:Motion_Sensor,,,,,,brick:EnumerationKind-Motion,brick:Sensor,,Detects the presence of motion in some area -brick:Motor_Current_Sensor,,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor -brick:Motor_Direction_Status,,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" -brick:Motor_On_Off_Status,,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, -brick:Motor_Speed_Sensor,,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, -brick:Motor_Torque_Sensor,,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" -brick:Natural_Gas_Flow_Sensor,,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas -brick:Natural_Gas_Temperature_Sensor,,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas -brick:Natural_Gas_Usage_Sensor,,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system -brick:NO2_Level_Sensor,,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air -brick:Occupancy_Command,,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" -brick:Occupancy_Count_Sensor,,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area -brick:Occupancy_Sensor,,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area -brick:Occupancy_Status,,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied -brick:Occupied_Air_Temperature_Setpoint,,brick:Occupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when occupied -brick:Occupied_Cooling_Mode_Status,,brick:Occupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,, -brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling when occupied -brick:Occupied_Cooling_Temperature_Deadband_Setpoint,,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for cooling when occupied -brick:Occupied_Cooling_Temperature_Setpoint,,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling when occupied -brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,,brick:Occupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air cooling when occupied -brick:Occupied_Discharge_Air_Flow_Setpoint,,brick:Occupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow when occupied -brick:Occupied_Discharge_Air_Temperature_Setpoint,,brick:Occupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating when occupied -brick:Occupied_Heating_Mode_Status,,brick:Occupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,, -brick:Occupied_Heating_Supply_Air_Flow_Setpoint,,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating when occupied -brick:Occupied_Heating_Temperature_Deadband_Setpoint,,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for heating when occupied -brick:Occupied_Heating_Temperature_Setpoint,,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating when occupied -brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,,brick:Occupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air heating when occupied -brick:Occupied_Humidity_Setpoint,,brick:Occupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is occupied. -brick:Occupied_Load_Shed_Command,,brick:Occupied,brick:Load_Shed,,,,brick:Command,, -brick:Occupied_Mode_Status,,brick:Occupied,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates if a system, device or control loop is in ""Occupied"" mode" -brick:Occupied_Return_Air_Temperature_Setpoint,,brick:Occupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Occupied_Room_Air_Temperature_Setpoint,,brick:Occupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Occupied_Supply_Air_Flow_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied -brick:Occupied_Supply_Air_Temperature_Setpoint,,brick:Occupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Occupied_Target_Zone_Air_Temperature_Setpoint,,brick:Occupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. -brick:Off_Command,,,,,,brick:On_Off-Off,brick:Command,,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" -brick:Off_Status,,,,,,brick:On_Off-Off,brick:Status,,"Indicates if a control loop, relay or equipment is off" -brick:On_Command,,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" -brick:On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" -brick:On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" -brick:On_Status,,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" -brick:On_Timer_Sensor,,,,,,,,(deprecated),"Measures the duration for which a device was in an active or ""on"" state" -brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" -brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve -brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,,(deprecated), -brick:Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" -brick:Output_Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,Output, -brick:Output_Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device -brick:Outside_Air_CO_Sensor,,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air -brick:Outside_Air_CO2_Sensor,,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air -brick:Outside_Air_Dewpoint_Sensor,,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air -brick:Outside_Air_Enthalpy_Sensor,,,,brick:Outside_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air -brick:Outside_Air_Flow_Sensor,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system -brick:Outside_Air_Flow_Setpoint,,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate -brick:Outside_Air_Grains_Sensor,,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air -brick:Outside_Air_Humidity_Sensor,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air -brick:Outside_Air_Humidity_Setpoint,,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air -brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,, -brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Lockout,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,,(deprecated), -brick:Outside_Air_Temperature_High_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Outside_Air_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air -brick:Outside_Air_Temperature_Setpoint,,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air -brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air -brick:Outside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. -brick:Outside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. -brick:Outside_Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" -brick:Overload_Alarm,,,,,,,,(deprecated),An alarm that can indicate when a full-load current is exceeded. -brick:Overridden_Off_Status,,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" -brick:Overridden_On_Status,,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" -brick:Overridden_Status,,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden -brick:Override_Command,,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' -brick:Ozone_Level_Sensor,,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air -brick:Parameter,,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values -brick:Particulate_Matter_Sensor,,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air -brick:Peak_Demand_Sensor,brick:Peak,,,,,,brick:Demand_Sensor,,The peak power consumed by a process over some period of time -brick:Photovoltaic_Current_Output_Sensor,,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device -brick:PID_Parameter,,,,,,,,(deprecated), -brick:Piezoelectric_Sensor,,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" -brick:PIR_Sensor,,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors -brick:PM1_Level_Sensor,,,,brick:PM1.0,,,brick:Sensor,Level,Detects level of particulates of size 1 microns -brick:PM1_Sensor,,,,brick:PM1.0,,,brick:Sensor,,Detects matter of size 1 micron -brick:PM10_Level_Sensor,,,,brick:PM10.0,,,brick:Sensor,Level,Detects level of particulates of size 10 microns -brick:PM10_Sensor,,,,brick:PM10.0,,,brick:Sensor,,Detects matter of size 10 microns -brick:PM2.5_Level_Sensor,,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns -brick:PM2.5_Sensor,,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns -brick:Position_Command,,,,,,,brick:Command,Position,Controls or reports the position of some object -brick:Position_Limit,,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. -brick:Position_Sensor,,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion -brick:Power_Alarm,,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. -brick:Power_Factor_Sensor,,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." -brick:Power_Loss_Alarm,,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. -brick:Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed -brick:Pre_Filter_Status,,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced -brick:Preheat_Command,,,brick:Preheat,,,,brick:Command,,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer -brick:Preheat_Demand_Setpoint,,,brick:Preheat,,,,brick:Demand_Setpoint,,Sets the rate required for preheat -brick:Preheat_Discharge_Air_Temperature_Sensor,,,brick:Preheat,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air before heating is applied -brick:Preheat_Supply_Air_Temperature_Sensor,,,brick:Preheat,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air before it is heated -brick:Pressure_Alarm,,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. -brick:Pressure_Sensor,,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area -brick:Pressure_Setpoint,,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure -brick:Pressure_Status,,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds -brick:Proportional_Band_Parameter,,,,,,,brick:Proportional_Band_Parameter,, -brick:Proportional_Gain_Parameter,,,,,,,brick:Proportional_Gain_Parameter,, -brick:Pump_Command,,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) -brick:Pump_On_Off_Status,,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, -brick:Pump_Status,,,brick:Pump,,,,brick:Status,,Status of a pump -brick:PV_Current_Output_Sensor,,,,,,,,(deprecated),See Photovoltaic_Current_Output_Sensor -brick:Radiant_Panel_Temperature_Sensor,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. -brick:Radiant_Panel_Temperature_Setpoint,,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. -brick:Radon_Concentration_Sensor,,,,brick:Rn,,quantitykind:ActivityConcentration,brick:Sensor,,Measures the concentration of radioactivity due to radon -brick:Rain_Duration_Sensor,,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame -brick:Rain_Level_Sensor,,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,,,,(deprecated),Sets rated speed -brick:Reactive_Energy_Sensor,,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power -brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" -brick:Refrigerant_Level_Sensor,,,,brick:Refrigerant,,,brick:Sensor,Level, -brick:Reheat_Command,,,,,,,,(deprecated),"A command to activate reheating, which is used for either heating or for dehumidification purposes" -brick:Relative_Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature -brick:Relay_Command,,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,,,,(deprecated), -brick:Reset_Command,,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" -brick:Reset_Setpoint,,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies -brick:Return_Air_CO_Sensor,,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air -brick:Return_Air_CO2_Sensor,,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air -brick:Return_Air_CO2_Setpoint,,,,brick:Return_Air,,,brick:Setpoint,CO2,Sets some property of CO2 in Return Air -brick:Return_Air_Dewpoint_Sensor,,,,brick:Return_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air -brick:Return_Air_Differential_Pressure_Sensor,,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side -brick:Return_Air_Differential_Pressure_Setpoint,,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit -brick:Return_Air_Enthalpy_Sensor,,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air -brick:Return_Air_Flow_Sensor,,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air -brick:Return_Air_Grains_Sensor,,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air -brick:Return_Air_Humidity_Sensor,,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air -brick:Return_Air_Humidity_Setpoint,,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air -brick:Return_Air_Temperature_Alarm,,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. -brick:Return_Air_Temperature_High_Reset_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Return_Air_Temperature_Low_Reset_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Return_Air_Temperature_Sensor,,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air -brick:Return_Air_Temperature_Setpoint,,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" -brick:Room_Air_Temperature_Sensor,,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, -brick:Room_Air_Temperature_Setpoint,,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air -brick:Run_Enable_Command,,,,,,,brick:Enable_Command,Run, -brick:Run_Request_Status,,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment -brick:Run_Status,,,,,,,brick:Status,Run, -brick:Run_Time_Sensor,,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" -brick:Sash_Position_Sensor,,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open -brick:Schedule_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule -brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). -brick:Sensor_Failure_Alarm,,,,,,,,(deprecated), -brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set -brick:Short_Cycle_Alarm,,,,,,,,(deprecated),An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle -brick:Smoke_Alarm,,,,brick:Smoke,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with smoke. -brick:Smoke_Detection_Alarm,,,brick:Smoke_Detection,,,,brick:Alarm,, -brick:Soil_Temperature_Sensor,,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil -brick:Solar_Azimuth_Angle_Sensor,,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun -brick:Solar_Irradiance_Sensor,,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems -brick:Solar_Zenith_Angle_Sensor,,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun -brick:Speed_Command,,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. -brick:Speed_Mode_Status,,,,,,brick:EnumerationKind-Speed_Mode,brick:Status,,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." -brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, -brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement -brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed -brick:Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. -brick:Stage_Enable_Command,,,,,,,,(deprecated),A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property -brick:Stages_Status,,,,,,,,(deprecated),Indicates which stage a control loop or equipment is in -brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit -brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Standby, -brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, -brick:Standby_Unit_On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Unit,Indicates the on/off status of a standby unit -brick:Start_Stop_Command,,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence -brick:Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) -brick:Static_Pressure_Deadband_Setpoint,,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure -brick:Static_Pressure_Integral_Time_Parameter,,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, -brick:Static_Pressure_Proportional_Band_Parameter,,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Static_Pressure_Sensor,,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work -brick:Static_Pressure_Setpoint,,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure -brick:Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. -brick:Static_Pressure_Step_Parameter,,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Status,,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" -brick:Steam_On_Off_Command,,,,brick:Steam,,brick:EnumerationKind-On_Off,brick:Command,, -brick:Steam_Usage_Sensor,,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" -brick:Step_Parameter,,,,,,,brick:Step_Parameter,, -brick:Supply_Air_Dewpoint_Sensor,,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, -brick:Supply_Air_Differential_Pressure_Sensor,,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building -brick:Supply_Air_Differential_Pressure_Setpoint,,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit -brick:Supply_Air_Duct_Pressure_Status,,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds -brick:Supply_Air_Flow_Demand_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process -brick:Supply_Air_Flow_High_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, -brick:Supply_Air_Flow_Low_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, -brick:Supply_Air_Flow_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, -brick:Supply_Air_Flow_Sensor,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air -brick:Supply_Air_Flow_Setpoint,,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate -brick:Supply_Air_Humidity_Sensor,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air -brick:Supply_Air_Humidity_Setpoint,,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air -brick:Supply_Air_Integral_Gain_Parameter,,,,brick:Supply_Air,,,brick:Integral_Gain_Parameter,, -brick:Supply_Air_Proportional_Gain_Parameter,,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, -brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Smoke_Detection,brick:Supply_Air,,,brick:Alarm,, -brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air -brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, -brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, -brick:Supply_Air_Static_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system -brick:Supply_Air_Static_Pressure_Setpoint,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air -brick:Supply_Air_Static_Pressure_Step_Parameter,,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, -brick:Supply_Air_Temperature_Alarm,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. -brick:Supply_Air_Temperature_Cooling_Setpoint,,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Supply_Air_Temperature_Deadband_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air -brick:Supply_Air_Temperature_Heating_Setpoint,,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Supply_Air_Temperature_High_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, -brick:Supply_Air_Temperature_Sensor,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air -brick:Supply_Air_Temperature_Setpoint,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air -brick:Supply_Air_Temperature_Setpoint_Limit,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. -brick:Supply_Air_Temperature_Step_Parameter,,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Supply_Air_Velocity_Pressure_Sensor,,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, -brick:Switch_Status,,,brick:Switch,,,,brick:Status,,Status of a switch -brick:System_Enable_Command,,,brick:System,,,,brick:Enable_Command,,Enables operation of a system -brick:System_Shutdown_Status,,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown -brick:System_Status,,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system -brick:Target_Zone_Air_Temperature_Setpoint,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, -brick:Temperature_Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of temperature -brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. -brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. -brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature -brick:Temperature_Differential_Reset_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, -brick:Temperature_High_Reset_Setpoint,,,,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, -brick:Temperature_Low_Reset_Setpoint,,,,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, -brick:Temperature_Parameter,,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points -brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold -brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature -brick:Temperature_Step_Parameter,,,,,,quantitykind:Temperature,brick:Step_Parameter,, -brick:Temperature_Tolerance_Parameter,,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. -brick:Temporary_Occupancy_Status,,,,,,,,(deprecated),"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" -brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period -brick:Thermal_Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,Thermal, -brick:Thermostat_Status,,,brick:Thermostat,,,,brick:Status,,Status of a thermostat -brick:Time_Parameter,,,,,,,brick:Parameter,Time, -brick:Time_Setpoint,,,,,,,brick:Time_Setpoint,, -brick:Tint_Command,,,,,,,brick:Command,Tint,The target level of window tint. -brick:Tint_Status,,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." -brick:Tolerance_Parameter,,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. -brick:Torque_Sensor,,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" -brick:TVOC_Level_Sensor,,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the level of all VOCs in air -brick:TVOC_Sensor,,,,brick:VOC,,,brick:Sensor,, -brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum -brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure -brick:Underfloor_Air_Temperature_Sensor,,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air -brick:Unit_Failure_Alarm,,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device -brick:Unoccupied_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied -brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied -brick:Unoccupied_Cooling_Mode_Status,,brick:Unoccupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" -brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,, -brick:Unoccupied_Cooling_Temperature_Setpoint,,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,, -brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for cooling within a specific zone -brick:Unoccupied_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Unoccupied_Discharge_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Unoccupied_Heating_Mode_Status,,brick:Unoccupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied heating mode" -brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,, -brick:Unoccupied_Heating_Temperature_Setpoint,,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,, -brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for heating within a specific zone -brick:Unoccupied_Humidity_Setpoint,,brick:Unoccupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is unoccupied. -brick:Unoccupied_Load_Shed_Command,,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,, -brick:Unoccupied_Mode_Status,,brick:Unoccupied,,,,brick:EnumerationKind-Mode,brick:Status,, -brick:Unoccupied_Return_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Unoccupied_Room_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Unoccupied_Supply_Air_Flow_Setpoint,,brick:Unoccupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, -brick:Unoccupied_Supply_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, -brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,,brick:Unoccupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. -brick:Usage_Sensor,,,,,,,brick:Sensor,Usage,"Measures the amount of some substance that is consumed or used, over some period of time" -brick:Valve_Command,,,brick:Valve,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) -brick:Valve_Position_Alarm,,,brick:Valve,,,,brick:Alarm,Position,An alarm that indicates that the valve position is not in a normal state. -brick:Valve_Position_Command,,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve -brick:Valve_Position_Sensor,,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open -brick:Valve_Status,,,brick:Valve,,,,brick:Status,,The current status of the valve. -brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure -brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated),Indicates the current operating mode of a vent -brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. -brick:VFD_Enable_Command,,,brick:VFD,,,,brick:Enable_Command,,Enables operation of a variable frequency drive -brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. -brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system -brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer -brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object -brick:Warm_Cool_Adjust_Sensor,,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" -brick:Warmest_Zone_Air_Temperature_Sensor,brick:Warmest,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' -brick:Waste_Amount_Sensor,,,,,,,,(deprecated),A metric used for measuring the quantity of waste generated in a building. -brick:Water_Alarm,,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" -brick:Water_Differential_Pressure_Sensor,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. -brick:Water_Differential_Pressure_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit -brick:Water_Differential_Temperature_Sensor,,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit -brick:Water_Differential_Temperature_Setpoint,,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit -brick:Water_Flow_Sensor,,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water -brick:Water_Flow_Setpoint,,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water -brick:Water_Level_Alarm,,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin -brick:Water_Level_Sensor,,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container -brick:Water_Loss_Alarm,,,,brick:Water,,,brick:Loss_Alarm,,An alarm that indicates a loss of water e.g. during transport -brick:Water_Pressure_Sensor,,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. -brick:Water_Pressure_Setpoint,,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, -brick:Water_Temperature_Alarm,,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. -brick:Water_Temperature_Sensor,,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water -brick:Water_Temperature_Setpoint,,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water -brick:Water_Usage_Sensor,,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" -brick:Wind_Direction_Sensor,,,,brick:Wind,,,brick:Sensor,Direction,Measures the direction of wind in degrees relative to North -brick:Wind_Speed_Sensor,,,,brick:Wind,,quantitykind:Speed,brick:Sensor,,"Measured speed of wind, caused by air moving from high to low pressure" -brick:Zone_Air_Conditioning_Mode_Status,,,,brick:Zone_Air,,brick:EnumerationKind-Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone -brick:Zone_Air_Dewpoint_Sensor,,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air -brick:Zone_Air_Humidity_Sensor,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air -brick:Zone_Air_Humidity_Setpoint,,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air -brick:Zone_Air_Temperature_Sensor,,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone -brick:Zone_CO2_Level_Sensor,,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone -brick:Zone_Occupied_Load_Shed_Command,,brick:Occupied,brick:Load_Shed,,,,brick:Command,Zone, -brick:Zone_Standby_Load_Shed_Command,,,brick:Load_Shed,,,,brick:Command,Zone Standby, -brick:Zone_Unoccupied_Load_Shed_Command,,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,Zone, +@id,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition +brick:Absolute_Humidity_Sensor,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity +brick:Acceleration_Time_Setpoint,,brick:Acceleration,,,,brick:Time_Setpoint,, +brick:Active_Power_Sensor,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" +brick:Adjust_Sensor,,,,,,,(deprecated),Measures user-provided adjustment of some value +brick:Air_Alarm,,,brick:Air,,,brick:Alarm,, +brick:Air_Differential_Pressure_Sensor,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air +brick:Air_Differential_Pressure_Setpoint,,,brick:Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit +brick:Air_Enthalpy_Sensor,,,brick:Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air +brick:Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. +brick:Air_Flow_Deadband_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow +brick:Air_Flow_Demand_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of air flow required for a process +brick:Air_Flow_Loss_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. +brick:Air_Flow_Sensor,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air +brick:Air_Flow_Setpoint,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow +brick:Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Air_Grains_Sensor,,,brick:Air,,,brick:Sensor,Grains,Measures the mass of water vapor in air +brick:Air_Pressure_Sensor,,,brick:Air,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. +brick:Air_Pressure_Setpoint,,,brick:Air,,quantitykind:Pressure,brick:Setpoint,, +brick:Air_Quality_Sensor,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality +brick:Air_Static_Pressure_Sensor,,,brick:Air,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." +brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Air_Temperature_Alarm,,,brick:Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. +brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air +brick:Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air +brick:Air_Temperature_Setpoint_Limit,,,brick:Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. +brick:Air_Temperature_Step_Parameter,,,brick:Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. +brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,quantitykind:WetBulbTemperature,brick:Sensor,, +brick:Alarm,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action +brick:Alarm_Delay_Parameter,,,,,,brick:Alarm_Delay_Parameter,,A parameter determining how long to delay an alarm after sufficient conditions have been met +brick:Alarm_Sensitivity_Parameter,,,,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate an alarm. +brick:Ammonia_Sensor,,,brick:NH3,,,brick:Sensor,,Measures the concentration of ammonia in air +brick:Angle_Sensor,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon +brick:Automatic_Mode_Command,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" +brick:Availability_Status,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" +brick:Average_Cooling_Demand_Sensor,,brick:Cooling,,,,brick:Average_Demand_Sensor,,Measures the average power consumed by a cooling process as the amount of power consumed over some interval +brick:Average_Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Average_Sensor,,The computed average flow of discharge air over some interval +brick:Average_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Average_Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Average_Heating_Demand_Sensor,,brick:Heating,,,,brick:Average_Demand_Sensor,,Measures the average power consumed by a heating process as the amount of power consumed over some interval +brick:Average_Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Average_Sensor,,The computed average flow of supply air over some interval +brick:Average_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Average_Sensor,,"The computed average temperature of air in a zone, over some period of time" +brick:Battery_Voltage_Sensor,,brick:Battery,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery +brick:Boiler_Command,,brick:Boiler,,,,brick:Command,,A command to control a boiler +brick:Box_Mode_Command,,,,,,,(deprecated), +brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building +brick:Building_Air_Static_Pressure_Sensor,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building +brick:Building_Air_Static_Pressure_Setpoint,,,brick:Building_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building +brick:Bypass_Air_Flow_Sensor,,,brick:Bypass_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air +brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air +brick:Bypass_Command,,,,,,,(deprecated), +brick:Bypass_Water_Flow_Sensor,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water +brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water +brick:Capacity_Sensor,,,,,quantitykind:Capacity,brick:Sensor,, +brick:Change_Filter_Alarm,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed +brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water +brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Chilled_Water_Differential_Pressure_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve +brick:Chilled_Water_Differential_Pressure_Setpoint,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water +brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Chilled_Water_Differential_Temperature_Sensor,,,brick:Chilled_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device +brick:Chilled_Water_Flow_Sensor,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit +brick:Chilled_Water_Flow_Setpoint,,,brick:Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water +brick:Chilled_Water_Gauge_Pressure_Sensor,,,brick:Chilled_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water +brick:Chilled_Water_Static_Pressure_Setpoint,,,brick:Chilled_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water +brick:Chilled_Water_System_Enable_Command,,brick:Chilled_Water_System,,,,brick:Enable_Command,,Enables operation of the chilled water system +brick:Chilled_Water_Temperature_Sensor,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water +brick:Chilled_Water_Temperature_Setpoint,,,brick:Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water +brick:Close_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. +brick:CO_Differential_Sensor,,,brick:CO,brick:Differential,,brick:Sensor,, +brick:CO_Level_Sensor,,,brick:CO,,,brick:Sensor,Level,Measures the concentration of CO +brick:CO_Sensor,,,brick:CO,,,brick:Sensor,,Measures properties of CO +brick:CO2_Alarm,,,brick:CO2,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. +brick:CO2_Alarm_Sensitivity_Parameter,,,brick:CO2,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a CO2 alarm. +brick:CO2_Differential_Sensor,,,brick:CO2,brick:Differential,,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air +brick:CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air +brick:CO2_Sensor,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air +brick:CO2_Setpoint,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 +brick:Coldest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Coldest,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Command,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. +brick:Communication_Loss_Alarm,,,,,brick:EnumerationKind-CommunicationState,brick:Loss_Alarm,,An alarm that indicates a loss of communication e.g. with a device or controller +brick:Condensate_Leak_Alarm,,,brick:Condensate,,,brick:Leak_Alarm,,An alarm that indicates a leak of condensate from a cooling system +brick:Condenser_Water_Flow_Sensor,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water +brick:Condenser_Water_Flow_Setpoint,,,brick:Condenser_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Condenser_Water_Temperature_Sensor,,,brick:Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water +brick:Conductivity_Sensor,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance +brick:Contact_Sensor,,,,,,,(deprecated),"Senses or detects contact, such as for determining if a door is closed." +brick:Cooling_Command,,brick:Cooling,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) +brick:Cooling_Demand_Sensor,,brick:Cooling,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Cooling_Demand_Setpoint,,brick:Cooling,,,,brick:Demand_Setpoint,,Sets the rate required for cooling +brick:Cooling_Discharge_Air_Flow_Setpoint,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling +brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of cooling discharge air +brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Enable_Command,,brick:Cooling,,,,brick:Enable_Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Mode_Status,,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" +brick:Cooling_Start_Stop_Status,,brick:Cooling,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Cooling_Supply_Air_Flow_Setpoint,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling +brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for cooling +brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Temperature_Setpoint,,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling +brick:Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The cooling setpoint for a specific zone in a building. +brick:Core_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. +brick:Core_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." +brick:Current_Imbalance_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system +brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. +brick:Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device +brick:Current_Ratio_Setpoint,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer +brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor +brick:Curtailment_Override_Command,,,,,,,(deprecated), +brick:Cycle_Alarm,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with HVAC cycles +brick:Damper_Command,,brick:Damper,,,,brick:Command,,Controls properties of dampers +brick:Damper_Position_Command,,brick:Damper,,,,brick:Command,Position,Controls the position (the degree of openness) of a damper +brick:Damper_Position_Sensor,,brick:Damper,,,,brick:Sensor,Position,Measures the current position of a damper in terms of the percent of fully open +brick:Damper_Position_Setpoint,,brick:Damper,,,,brick:Setpoint,Position,Sets the position of damper +brick:Damper_Position_Status,,brick:Damper,,,,brick:Status,Position, +brick:DC_Bus_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage across a DC bus +brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband +brick:Deceleration_Time_Setpoint,,brick:Deceleration,,,,brick:Time_Setpoint,, +brick:Dehumidification_Start_Stop_Status,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. +brick:Deionized_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water +brick:Deionized_Water_Level_Sensor,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container +brick:Delay_Parameter,,,,,,brick:Delay_Parameter,,A parameter determining how long to delay a subsequent action to take place after a received signal +brick:Demand_Sensor,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Demand_Setpoint,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process +brick:Derivative_Gain_Parameter,,,,,,brick:Derivative_Gain_Parameter,, +brick:Derivative_Time_Parameter,,,,,,brick:Derivative_Time_Parameter,, +brick:Dewpoint_Sensor,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor +brick:Dewpoint_Setpoint,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point +brick:Differential_Air_Temperature_Setpoint,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure +brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Differential_Pressure_Proportional_Band_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures +brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure +brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. +brick:Differential_Pressure_Step_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements +brick:Differential_Speed_Sensor,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, +brick:Differential_Speed_Setpoint,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed +brick:Differential_Temperature_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements +brick:Direction_Command,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon +brick:Direction_Sensor,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring +brick:Direction_Status,,,,,,brick:Status,Direction,Indicates which direction a device is operating in +brick:Disable_Command,,,,,,brick:Disable_Command,,Commands that disable functionality +brick:Disable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Disable_Command,,Disables the use of differential enthalpy control +brick:Disable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Disable_Command,,Disables the use of differential temperature control +brick:Disable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Disable_Command,Fixed,Disables the use of fixed enthalpy control +brick:Disable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Disable_Command,Fixed,Disables the use of fixed temperature temperature +brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Disable_Setpoint,,Disables hot water system when outside air temperature reaches the indicated value +brick:Disable_Status,,,,,,brick:Disable_Status,,Indicates if functionality has been disabled +brick:Discharge_Air_Dewpoint_Sensor,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air +brick:Discharge_Air_Differential_Pressure_Sensor,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, +brick:Discharge_Air_Differential_Pressure_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Discharge_Air_Duct_Pressure_Status,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds +brick:Discharge_Air_Flow_Demand_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of discharge air flow required for a process +brick:Discharge_Air_Flow_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, +brick:Discharge_Air_Flow_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies +brick:Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of discharge air +brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow +brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of discharge air +brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for discharge air +brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,brick:Integral_Gain_Parameter,, +brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,brick:Proportional_Gain_Parameter,, +brick:Discharge_Air_Smoke_Detection_Alarm,,brick:Smoke_Detection,brick:Discharge_Air,,,brick:Alarm,, +brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Discharge_Air_Static_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within discharge regions of an HVAC system +brick:Discharge_Air_Static_Pressure_Setpoint,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of discharge air +brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of discharge air. +brick:Discharge_Air_Temperature_Cooling_Setpoint,,brick:Cooling,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for cooling +brick:Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of discharge air +brick:Discharge_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air for heating +brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air +brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. +brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,brick:Domestic_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water +brick:Domestic_Hot_Water_System_Enable_Command,,brick:Domestic_Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water +brick:Drive_Ready_Status,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" +brick:Duct_Air_Static_Pressure_Setpoint,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, +brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event +brick:EconCycle_Start_Stop_Status,,,,,,,(deprecated), +brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. +brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective heating setpoint for a specific zone in a building. +brick:Effective_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Room_Air_Temperature_Setpoint,,,brick:Room_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width +brick:Electric_Energy_Sensor,,,,,,brick:Sensor,Electric Energy, +brick:Electric_Power_Sensor,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed +brick:Electrical_Energy_Usage_Sensor,,,,,,brick:Sensor,Electrical Energy Usage,A sensor that records the quantity of electrical energy consumed in a given period +brick:Embedded_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. +brick:Embedded_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." +brick:Emergency_Air_Flow_System_Status,,brick:Emergency_Air_Flow_System,,,,brick:Status,, +brick:Emergency_Alarm,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Generator_Alarm,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Status,,brick:Emergency_Power_Off_System,,,,brick:Status,, +brick:Emergency_Push_Button_Status,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed +brick:Enable_Command,,,,,,brick:Enable_Command,,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Enable_Command,,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Enable_Command,,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Enable_Command,Fixed,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Enable_Command,Fixed,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,,Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,brick:Enable_Status,,Indicates if a system or piece of functionality has been enabled +brick:Energy_Generation_Sensor,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. +brick:Energy_Sensor,,,,,,brick:Sensor,Energy,Measures energy consumption +brick:Energy_Usage_Sensor,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time +brick:Entering_Chilled_Water_Flow_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water +brick:Entering_Chilled_Water_Flow_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water +brick:Entering_Chilled_Water_Temperature_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower +brick:Entering_Chilled_Water_Temperature_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water +brick:Entering_Condenser_Water_Flow_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Sensor,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Setpoint,,,brick:Entering_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water +brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Entering_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Entering_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water enteringed to a hot water system +brick:Entering_Hot_Water_Flow_Sensor,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water +brick:Entering_Hot_Water_Flow_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water +brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Sensor,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water enteringed to a hot water system +brick:Entering_Hot_Water_Temperature_Setpoint,,,brick:Entering_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Entering_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water entering a hot water system +brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water +brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Flow_Sensor,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system +brick:Entering_Water_Flow_Setpoint,,,brick:Entering_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water +brick:Entering_Water_Pressure_Sensor,,,brick:Entering_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. +brick:Entering_Water_Temperature_Alarm,,,brick:Entering_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. +brick:Entering_Water_Temperature_Deadband_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water +brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water +brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water +brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance +brick:Enthalpy_Setpoint,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy +brick:Even_Month_Status,,,,,,,(deprecated), +brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air +brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building +brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit +brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air +brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate +brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air +brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air +brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, +brick:Exhaust_Air_Stack_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack +brick:Exhaust_Air_Stack_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate +brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system +brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air +brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air +brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Failure_Alarm,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" +brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans +brick:Fan_On_Off_Status,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans +brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans +brick:Fault_Reset_Command,,,,,,brick:Reset_Command,Fault,Clears a fault status +brick:Fault_Status,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" +brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. +brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter +brick:Filter_Reset_Command,,brick:Filter,,,,brick:Reset_Command,, +brick:Filter_Status,,brick:Filter,,,,brick:Status,,Indicates if a filter needs to be replaced +brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. +brick:Fire_Sensor,,,brick:Fire,,,brick:Sensor,,Measures the presence of fire +brick:Flow_Sensor,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance +brick:Flow_Setpoint,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow +brick:Formaldehyde_Level_Sensor,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air +brick:Freeze_Status,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen +brick:Frequency_Command,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) +brick:Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" +brick:Frequency_Setpoint,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency +brick:Fresh_Air_Setpoint_Limit,,,brick:Fresh_Air,,,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Frost_Sensor,,,brick:Frost,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost +brick:Fume_Hood_Air_Flow_Sensor,,brick:Fume_Hood,brick:Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood +brick:Gain_Parameter,,,,,,brick:Gain_Parameter,, +brick:Gas_Sensor,,,brick:Gas,,,brick:Sensor,,Measures gas concentration (other than CO2) +brick:Gauge_Pressure_Sensor,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure +brick:Generation_Sensor,,,,,,brick:Sensor,Generation,A sensor measuring how much something has been generated. +brick:Hail_Sensor,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential +brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, +brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger_System,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled +brick:Heat_Sink_Temperature_Sensor,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. +brick:Heating_Command,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) +brick:Heating_Demand_Sensor,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Heating_Demand_Setpoint,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating +brick:Heating_Discharge_Air_Flow_Setpoint,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating +brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of heating discharge air +brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,brick:Heating,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Enable_Command,,brick:Heating,,,,brick:Enable_Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Mode_Status,,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" +brick:Heating_Start_Stop_Status,,brick:Heating,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Heating_Supply_Air_Flow_Setpoint,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating +brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for heating +brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Temperature_Setpoint,,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating +brick:Heating_Thermal_Power_Sensor,,brick:Heating,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,The heating setpoint for a specific zone in a building. +brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. +brick:High_CO2_Alarm,,,brick:CO2,,,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. +brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that discharge air temperature is too high +brick:High_Head_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,,The upper bound of the outside air temperature lockout range +brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. +brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, +brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. +brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm +brick:Hold_Status,,,,,,,(deprecated), +brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water +brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve +brick:Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water +brick:Hot_Water_Differential_Temperature_Sensor,,,brick:Hot_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device +brick:Hot_Water_Flow_Sensor,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit +brick:Hot_Water_Flow_Setpoint,,,brick:Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water +brick:Hot_Water_Gauge_Pressure_Sensor,,,brick:Hot_Water,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water +brick:Hot_Water_Static_Pressure_Setpoint,,,brick:Hot_Water,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air +brick:Hot_Water_System_Enable_Command,,brick:Hot_Water_System,,,,brick:Enable_Command,,Enables operation of the hot water system +brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water +brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" +brick:Humidification_Start_Stop_Status,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier +brick:Humidify_Command,,,,,,brick:Command,Humidify, +brick:Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. +brick:Humidity_Deadband_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity +brick:Humidity_Parameter,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points +brick:Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air +brick:Humidity_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity +brick:Humidity_Tolerance_Parameter,,,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. +brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Ice_Tank,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving an ice tank +brick:Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" +brick:Illuminance_Setpoint,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. +brick:Imbalance_Sensor,,,,,,brick:Sensor,Imbalance,A sensor which measures difference (imbalance) between phases of an electrical system +brick:Inside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. +brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. +brick:Intake_Air_Temperature_Sensor,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside +brick:Integral_Gain_Parameter,,,,,,brick:Integral_Gain_Parameter,, +brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, +brick:Last_Fault_Code_Status,,,,,,,(deprecated),Indicates the last fault code that occurred +brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation +brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled +brick:Lead_On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" +brick:Leak_Alarm,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids +brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water +brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water +brick:Leaving_Chilled_Water_Temperature_Sensor,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller +brick:Leaving_Chilled_Water_Temperature_Setpoint,,,brick:Leaving_Chilled_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water +brick:Leaving_Condenser_Water_Flow_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Sensor,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Setpoint,,,brick:Leaving_Condenser_Water,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water +brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of domestic water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leavinging part of domestic hot water +brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Leaving_High_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water supplied by a hot water system +brick:Leaving_Hot_Water_Flow_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water +brick:Leaving_Hot_Water_Flow_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water +brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Sensor,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system +brick:Leaving_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,brick:Load_Shed,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Status,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Leaving_Medium_Temperature_Hot_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water supplied by a hot water system +brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water +brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Flow_Sensor,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system +brick:Leaving_Water_Flow_Setpoint,,,brick:Leaving_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water +brick:Leaving_Water_Pressure_Sensor,,,brick:Leaving_Water,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. +brick:Leaving_Water_Temperature_Alarm,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. +brick:Leaving_Water_Temperature_Deadband_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water +brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system +brick:Leaving_Water_Temperature_Setpoint,,,brick:Leaving_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water +brick:Level_Command,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. +brick:Level_Status,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. +brick:Lighting_Correlated_Color_Temperature_Command,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Correlated_Color_Temperature_Sensor,,brick:Lighting,,,quantitykind:CorrelatedColorTemperature,brick:Sensor,,A sensor to measure correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Level_Command,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. +brick:Limit,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point +brick:Liquid_Detection_Alarm,,brick:Liquid_Detection,,,,brick:Alarm,, +brick:Load_Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load +brick:Load_Parameter,,,,,,brick:Parameter,Load, +brick:Load_Setpoint,,,,,,brick:Setpoint,Load, +brick:Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,,Controls load shedding behavior provided by a control system +brick:Load_Shed_Differential_Pressure_Setpoint,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Load_Shed_Setpoint,,brick:Load_Shed,,,,brick:Setpoint,, +brick:Load_Shed_Status,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect +brick:Locally_On_Off_Status,,,,,,,(deprecated), +brick:Lockout_Status,,brick:Lockout,,,,brick:Status,,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,brick:Lockout,,brick:Differential,quantitykind:Temperature,brick:Parameter,, +brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. +brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. +brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. +brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Alarm,, +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,(deprecated), +brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), +brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,(deprecated), +brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low +brick:Low_Suction_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,, +brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Alarm,, +brick:Low_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. +brick:Low_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Low_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm +brick:Low_Voltage_Alarm,,,,,quantitykind:Voltage,brick:Low_Alarm,,An alarm that indicates the voltage is lower than its normal state. +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,Lowest,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Luminance_Alarm,,,,,quantitykind:Luminance,brick:Alarm,, +brick:Luminance_Command,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system +brick:Luminance_Sensor,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction +brick:Luminance_Setpoint,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance +brick:Maintenance_Mode_Command,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" +brick:Maintenance_Required_Alarm,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Manual_Auto_Status,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation +brick:Max_Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Max_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for maximum air temperature +brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Max_Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Max_Frequency_Command,,,,,quantitykind:Frequency,brick:Max_Command,,Sets the maximum permitted frequency +brick:Max_Fresh_Air_Setpoint_Limit,,,brick:Fresh_Air,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Max_Limit,,,,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. +brick:Max_Load_Setpoint,,,,,,brick:Max_Setpoint,Load, +brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Outside_Air_Flow_Setpoint_Limit,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Max_Position_Setpoint_Limit,,,,,,brick:Max_Limit,Position,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. +brick:Max_Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Max_Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Max_Temperature_Setpoint_Limit,,,,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. +brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Water_Level_Alarm,,,brick:Water,,,brick:Max_Alarm,Level,Alarm indicating that the maximum water level was reached +brick:Max_Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for max water temperature +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between sections of a medium temperature hot water system +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,brick:Medium_Temperature_Hot_Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Methane_Level_Sensor,,,brick:CH4,,,brick:Sensor,Level,Measures the concentration of methane in air +brick:Min_Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Min_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for minimum air temperature +brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,brick:Chilled_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint. +brick:Min_Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. +brick:Min_Frequency_Command,,,,,quantitykind:Frequency,brick:Min_Command,, +brick:Min_Fresh_Air_Setpoint_Limit,,,brick:Fresh_Air,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Min_Limit,,,,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. +brick:Min_Load_Setpoint,,,,,,brick:Min_Setpoint,Load, +brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Outside_Air_Flow_Setpoint_Limit,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Min_Position_Setpoint_Limit,,,,,,brick:Min_Limit,Position,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. +brick:Min_Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Min_Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Min_Temperature_Setpoint_Limit,,,,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. +brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Water_Level_Alarm,,,brick:Water,,,brick:Min_Alarm,Level,Alarm indicating that the minimum water level was reached +brick:Min_Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Min_Setpoint,,Setpoint for min water temperature +brick:Mixed_Air_Flow_Sensor,,,brick:Mixed_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air +brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air +brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air +brick:Mixed_Air_Temperature_Sensor,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air +brick:Mixed_Air_Temperature_Setpoint,,,brick:Mixed_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air +brick:Mode_Command,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the operating mode of a device or controller +brick:Mode_Status,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" +brick:Motion_Sensor,,,,,brick:EnumerationKind-Motion,brick:Sensor,,Detects the presence of motion in some area +brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor +brick:Motor_Direction_Status,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" +brick:Motor_On_Off_Status,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Motor_Speed_Sensor,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, +brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" +brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas +brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas +brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" +brick:No_Water_Alarm,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system +brick:NO2_Level_Sensor,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air +brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" +brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area +brick:Occupancy_Sensor,,,,,,brick:Sensor,Occupancy,Detects occupancy of some space or area +brick:Occupancy_Status,,,,,,brick:Status,Occupancy,Indicates if a room or space is occupied +brick:Occupied_Air_Temperature_Setpoint,brick:Occupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when occupied +brick:Occupied_Cooling_Mode_Status,brick:Occupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling when occupied +brick:Occupied_Cooling_Temperature_Deadband_Setpoint,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for cooling when occupied +brick:Occupied_Cooling_Temperature_Setpoint,brick:Occupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling when occupied +brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,brick:Occupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air cooling when occupied +brick:Occupied_Discharge_Air_Flow_Setpoint,brick:Occupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow when occupied +brick:Occupied_Discharge_Air_Temperature_Setpoint,brick:Occupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for heating when occupied +brick:Occupied_Heating_Mode_Status,brick:Occupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Occupied_Heating_Supply_Air_Flow_Setpoint,brick:Occupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating when occupied +brick:Occupied_Heating_Temperature_Deadband_Setpoint,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for heating when occupied +brick:Occupied_Heating_Temperature_Setpoint,brick:Occupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating when occupied +brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,brick:Occupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air heating when occupied +brick:Occupied_Humidity_Setpoint,brick:Occupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is occupied. +brick:Occupied_Load_Shed_Command,brick:Occupied,brick:Load_Shed,,,,brick:Command,, +brick:Occupied_Mode_Status,brick:Occupied,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates if a system, device or control loop is in ""Occupied"" mode" +brick:Occupied_Return_Air_Temperature_Setpoint,brick:Occupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Room_Air_Temperature_Setpoint,brick:Occupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Supply_Air_Flow_Setpoint,brick:Occupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied +brick:Occupied_Supply_Air_Temperature_Setpoint,brick:Occupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Target_Zone_Air_Temperature_Setpoint,brick:Occupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Off_Command,,,,,brick:On_Off-Off,brick:Command,,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" +brick:Off_Status,,,,,brick:On_Off-Off,brick:Status,,"Indicates if a control loop, relay or equipment is off" +brick:On_Command,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" +brick:On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" +brick:On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" +brick:On_Status,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" +brick:On_Timer_Sensor,,,,,,,(deprecated),"Measures the duration for which a device was in an active or ""on"" state" +brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" +brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" +brick:Output_Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,Output, +brick:Output_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device +brick:Outside_Air_CO_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air +brick:Outside_Air_CO2_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air +brick:Outside_Air_Dewpoint_Sensor,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air +brick:Outside_Air_Enthalpy_Sensor,,,brick:Outside_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air +brick:Outside_Air_Flow_Sensor,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system +brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate +brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air +brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air +brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,, +brick:Outside_Air_Lockout_Temperature_Setpoint,,brick:Lockout,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), +brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air +brick:Outside_Air_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air +brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air +brick:Outside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. +brick:Outside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. +brick:Outside_Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" +brick:Overload_Alarm,,,,,,,(deprecated),An alarm that can indicate when a full-load current is exceeded. +brick:Overridden_Off_Status,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" +brick:Overridden_On_Status,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" +brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden +brick:Override_Command,,,,,,brick:Override_Command,,Controls or reports whether or not a device or control loop is in 'override' +brick:Ozone_Level_Sensor,,,brick:O3,,,brick:Sensor,Level,Measures the concentration of ozone in air +brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values +brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air +brick:Peak_Demand_Sensor,,,,,,brick:Demand_Sensor,Peak,The peak power consumed by a process over some period of time +brick:Photovoltaic_Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device +brick:PID_Parameter,,,,,,,(deprecated), +brick:Piezoelectric_Sensor,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:PM1_Level_Sensor,,,brick:PM1.0,,,brick:Sensor,Level,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,brick:PM1.0,,,brick:Sensor,,Detects matter of size 1 micron +brick:PM10_Level_Sensor,,,brick:PM10.0,,,brick:Sensor,Level,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,brick:PM10.0,,,brick:Sensor,,Detects matter of size 10 microns +brick:PM2.5_Level_Sensor,,,brick:PM2.5,,,brick:Sensor,Level,Detects level of particulates of size 2.5 microns +brick:PM2.5_Sensor,,,brick:PM2.5,,,brick:Sensor,,Detects matter of size 2.5 microns +brick:Position_Command,,,,,,brick:Command,Position,Controls or reports the position of some object +brick:Position_Limit,,,,,,brick:Limit,Position,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. +brick:Position_Sensor,,,,,,brick:Sensor,Position,Measures the current position of a component in terms of a fraction of its full range of motion +brick:Power_Alarm,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. +brick:Power_Factor_Sensor,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." +brick:Power_Loss_Alarm,,,,,quantitykind:Power,brick:Loss_Alarm,,An alarm that indicates a power failure. +brick:Power_Sensor,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed +brick:Pre_Filter_Status,,brick:Pre_Filter,,,,brick:Status,,Indicates if a prefilter needs to be replaced +brick:Preheat_Command,,brick:Preheat,,,,brick:Command,,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer +brick:Preheat_Demand_Setpoint,,brick:Preheat,,,,brick:Demand_Setpoint,,Sets the rate required for preheat +brick:Preheat_Discharge_Air_Temperature_Sensor,,brick:Preheat,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air before heating is applied +brick:Preheat_Supply_Air_Temperature_Sensor,,brick:Preheat,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air before it is heated +brick:Pressure_Alarm,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. +brick:Pressure_Sensor,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area +brick:Pressure_Setpoint,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure +brick:Pressure_Status,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds +brick:Proportional_Band_Parameter,,,,,,brick:Proportional_Band_Parameter,, +brick:Proportional_Gain_Parameter,,,,,,brick:Proportional_Gain_Parameter,, +brick:Pump_Command,,brick:Pump,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) +brick:Pump_On_Off_Status,,brick:Pump,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Pump_Status,,brick:Pump,,,,brick:Status,,Status of a pump +brick:PV_Current_Output_Sensor,,,,,,,(deprecated),See Photovoltaic_Current_Output_Sensor +brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. +brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. +brick:Radon_Concentration_Sensor,,,brick:Rn,,quantitykind:ActivityConcentration,brick:Sensor,,Measures the concentration of radioactivity due to radon +brick:Rain_Duration_Sensor,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame +brick:Rain_Level_Sensor,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen +brick:Rated_Speed_Setpoint,,,,,,,(deprecated),Sets rated speed +brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power +brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" +brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, +brick:Reheat_Command,,,,,,,(deprecated),"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature +brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay +brick:Remotely_On_Off_Status,,,,,,,(deprecated), +brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" +brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies +brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air +brick:Return_Air_CO2_Sensor,,,brick:Return_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in return air +brick:Return_Air_CO2_Setpoint,,,brick:Return_Air,,,brick:Setpoint,CO2,Sets some property of CO2 in Return Air +brick:Return_Air_Dewpoint_Sensor,,,brick:Return_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air +brick:Return_Air_Differential_Pressure_Sensor,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side +brick:Return_Air_Differential_Pressure_Setpoint,,,brick:Return_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit +brick:Return_Air_Enthalpy_Sensor,,,brick:Return_Air,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air +brick:Return_Air_Flow_Sensor,,,brick:Return_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air +brick:Return_Air_Grains_Sensor,,,brick:Return_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in return air +brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air +brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air +brick:Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. +brick:Return_Air_Temperature_High_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Return_Air_Temperature_Low_Reset_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Return_Air_Temperature_Sensor,,,brick:Return_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air +brick:Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" +brick:Room_Air_Temperature_Sensor,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, +brick:Room_Air_Temperature_Setpoint,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air +brick:Run_Enable_Command,,,,,,brick:Enable_Command,Run, +brick:Run_Request_Status,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment +brick:Run_Status,,,,,,brick:Status,Run, +brick:Run_Time_Sensor,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" +brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule +brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). +brick:Sensor_Failure_Alarm,,,,,,,(deprecated), +brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set +brick:Short_Cycle_Alarm,,,,,,,(deprecated),An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Smoke_Alarm,,,brick:Smoke,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with smoke. +brick:Smoke_Detection_Alarm,,brick:Smoke_Detection,,,,brick:Alarm,, +brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil +brick:Solar_Azimuth_Angle_Sensor,,,brick:Solar,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun +brick:Solar_Irradiance_Sensor,,,brick:Solar,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems +brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun +brick:Speed_Command,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. +brick:Speed_Mode_Status,,,,,brick:EnumerationKind-Speed_Mode,brick:Status,,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Reset_Command,, +brick:Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement +brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed +brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. +brick:Stage_Enable_Command,,,,,,,(deprecated),A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,,(deprecated),Indicates which stage a control loop or equipment is in +brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit +brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, +brick:Standby_Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,Standby, +brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, +brick:Standby_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Unit,Indicates the on/off status of a standby unit +brick:Start_Stop_Command,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence +brick:Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) +brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure +brick:Static_Pressure_Integral_Time_Parameter,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Static_Pressure_Proportional_Band_Parameter,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Static_Pressure_Sensor,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work +brick:Static_Pressure_Setpoint,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure +brick:Static_Pressure_Setpoint_Limit,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Static_Pressure_Step_Parameter,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Status,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" +brick:Steam_On_Off_Command,,,brick:Steam,,brick:EnumerationKind-On_Off,brick:Command,, +brick:Steam_Usage_Sensor,,,brick:Steam,,,brick:Sensor,Usage,"Measures the amount of steam that is consumed or used, over some period of time" +brick:Step_Parameter,,,,,,brick:Step_Parameter,, +brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, +brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building +brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit +brick:Supply_Air_Duct_Pressure_Status,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds +brick:Supply_Air_Flow_Demand_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process +brick:Supply_Air_Flow_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, +brick:Supply_Air_Flow_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,, +brick:Supply_Air_Flow_Sensor,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air +brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate +brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air +brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air +brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,brick:Integral_Gain_Parameter,, +brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,brick:Proportional_Gain_Parameter,, +brick:Supply_Air_Smoke_Detection_Alarm,,brick:Smoke_Detection,brick:Supply_Air,,,brick:Alarm,, +brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air +brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Static_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system +brick:Supply_Air_Static_Pressure_Setpoint,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air +brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. +brick:Supply_Air_Temperature_Cooling_Setpoint,,brick:Cooling,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air +brick:Supply_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air +brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air +brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Switch_Status,,brick:Switch,,,,brick:Status,,Status of a switch +brick:System_Enable_Command,,brick:System,,,,brick:Enable_Command,,Enables operation of a system +brick:System_Shutdown_Status,,brick:System,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown +brick:System_Status,,brick:System,,,,brick:Status,,Indicates properties of the activity of a system +brick:Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target, +brick:Temperature_Adjust_Sensor,,,,,,,(deprecated),Measures user-provided adjustment of temperature +brick:Temperature_Alarm,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. +brick:Temperature_Alarm_Sensitivity_Parameter,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. +brick:Temperature_Deadband_Setpoint,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature +brick:Temperature_Differential_Reset_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_High_Reset_Setpoint,,,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Temperature_Low_Reset_Setpoint,,,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Temperature_Parameter,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points +brick:Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold +brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature +brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. +brick:Temporary_Occupancy_Status,,,,,,,(deprecated),"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Thermal_Energy_Usage_Sensor,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period +brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, +brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat +brick:Time_Parameter,,,,,,brick:Parameter,Time, +brick:Time_Setpoint,,,,,,brick:Time_Setpoint,, +brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. +brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." +brick:Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. +brick:Torque_Sensor,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" +brick:TVOC_Level_Sensor,,,brick:VOC,,,brick:Sensor,Level,A sensor measuring the level of all VOCs in air +brick:TVOC_Sensor,,,brick:VOC,,,brick:Sensor,, +brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum +brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure +brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air +brick:Unit_Failure_Alarm,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device +brick:Unoccupied_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied +brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied +brick:Unoccupied_Cooling_Mode_Status,brick:Unoccupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" +brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Cooling_Temperature_Setpoint,brick:Unoccupied,brick:Cooling,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,brick:Unoccupied,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for cooling within a specific zone +brick:Unoccupied_Discharge_Air_Flow_Setpoint,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Discharge_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Mode_Status,brick:Unoccupied,brick:Heating,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied heating mode" +brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,brick:Unoccupied,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Heating_Temperature_Setpoint,brick:Unoccupied,brick:Heating,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,brick:Unoccupied,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for heating within a specific zone +brick:Unoccupied_Humidity_Setpoint,brick:Unoccupied,,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is unoccupied. +brick:Unoccupied_Load_Shed_Command,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,, +brick:Unoccupied_Mode_Status,brick:Unoccupied,,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Unoccupied_Return_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Room_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Flow_Setpoint,brick:Unoccupied,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Usage_Sensor,,,,,,brick:Sensor,Usage,"Measures the amount of some substance that is consumed or used, over some period of time" +brick:Valve_Command,,brick:Valve,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) +brick:Valve_Position_Alarm,,brick:Valve,,,,brick:Alarm,Position,An alarm that indicates that the valve position is not in a normal state. +brick:Valve_Position_Command,,brick:Valve,,,,brick:Command,Position,Controls the position (the degree of openness) of a valve +brick:Valve_Position_Sensor,,brick:Valve,,,,brick:Sensor,Position,Measures the current position of a valve in terms of the percent of fully open +brick:Valve_Status,,brick:Valve,,,,brick:Status,,The current status of the valve. +brick:Velocity_Pressure_Sensor,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure +brick:Velocity_Pressure_Setpoint,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure +brick:Vent_Operating_Mode_Status,,,,,,,(deprecated),Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:VFD_Enable_Command,,brick:VFD,,,,brick:Enable_Command,,Enables operation of a variable frequency drive +brick:Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. +brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system +brick:Voltage_Ratio_Setpoint,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer +brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object +brick:Warm_Cool_Adjust_Sensor,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warmest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Warmest,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Waste_Amount_Sensor,,,,,,,(deprecated),A metric used for measuring the quantity of waste generated in a building. +brick:Water_Alarm,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" +brick:Water_Differential_Pressure_Sensor,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. +brick:Water_Differential_Pressure_Setpoint,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit +brick:Water_Differential_Temperature_Sensor,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit +brick:Water_Differential_Temperature_Setpoint,,,brick:Water,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit +brick:Water_Flow_Sensor,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water +brick:Water_Flow_Setpoint,,,brick:Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water +brick:Water_Level_Alarm,,,brick:Water,,,brick:Alarm,Level,An alarm that indicates a high or low water level e.g. in a basin +brick:Water_Level_Sensor,,,brick:Water,,,brick:Sensor,Level,Measures the height/level of water in some container +brick:Water_Loss_Alarm,,,brick:Water,,,brick:Loss_Alarm,,An alarm that indicates a loss of water e.g. during transport +brick:Water_Pressure_Sensor,,,brick:Water,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. +brick:Water_Pressure_Setpoint,,,brick:Water,,quantitykind:Pressure,brick:Setpoint,, +brick:Water_Temperature_Alarm,,,brick:Water,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. +brick:Water_Temperature_Sensor,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water +brick:Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water +brick:Water_Usage_Sensor,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" +brick:Wind_Direction_Sensor,,,brick:Wind,,,brick:Sensor,Direction,Measures the direction of wind in degrees relative to North +brick:Wind_Speed_Sensor,,,brick:Wind,,quantitykind:Speed,brick:Sensor,,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,brick:EnumerationKind-Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone +brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air +brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air +brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air +brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone +brick:Zone_CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone +brick:Zone_Occupied_Load_Shed_Command,brick:Occupied,brick:Load_Shed,,,,brick:Command,Zone, +brick:Zone_Standby_Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,Zone Standby, +brick:Zone_Unoccupied_Load_Shed_Command,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,Zone, From fc95b53ca55961b4d61ebeb91b2013a0f5875327 Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 30 Oct 2025 14:39:46 +0100 Subject: [PATCH 26/31] Define all point attributes [no ci] --- bricksrc/points.csv | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index d89ccbf4..72721907 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -1,6 +1,6 @@ @id,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition brick:Absolute_Humidity_Sensor,,,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity -brick:Acceleration_Time_Setpoint,,brick:Acceleration,,,,brick:Time_Setpoint,, +brick:Acceleration_Time_Setpoint,,brick:Acceleration,,,quantitykind:Time,brick:Setpoint,, brick:Active_Power_Sensor,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" brick:Adjust_Sensor,,,,,,,(deprecated),Measures user-provided adjustment of some value brick:Air_Alarm,,,brick:Air,,,brick:Alarm,, @@ -125,7 +125,7 @@ brick:Damper_Position_Setpoint,,brick:Damper,,,,brick:Setpoint,Position,Sets the brick:Damper_Position_Status,,brick:Damper,,,,brick:Status,Position, brick:DC_Bus_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage across a DC bus brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband -brick:Deceleration_Time_Setpoint,,brick:Deceleration,,,,brick:Time_Setpoint,, +brick:Deceleration_Time_Setpoint,,brick:Deceleration,,,quantitykind:Time,brick:Setpoint,, brick:Dehumidification_Start_Stop_Status,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. @@ -687,10 +687,10 @@ brick:Return_Air_Temperature_Sensor,,,brick:Return_Air,,quantitykind:Temperature brick:Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" brick:Room_Air_Temperature_Sensor,,,brick:Room_Air,,quantitykind:Temperature,brick:Sensor,, brick:Room_Air_Temperature_Setpoint,,,brick:Room_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air -brick:Run_Enable_Command,,,,,,brick:Enable_Command,Run, -brick:Run_Request_Status,,,,,,brick:Status,Run Request,Indicates if a request has been filed to start a device or equipment -brick:Run_Status,,,,,,brick:Status,Run, -brick:Run_Time_Sensor,,,,,,brick:Sensor,Run Time,"Measures the duration for which a device was in an active or ""on"" state" +brick:Run_Enable_Command,,brick:Run,,,,brick:Enable_Command,, +brick:Run_Request_Status,,brick:Run,,,,brick:Status,Request,Indicates if a request has been filed to start a device or equipment +brick:Run_Status,,brick:Run,,,,brick:Status,, +brick:Run_Time_Sensor,,brick:Run,,,quantitykind:Time,brick:Sensor,,"Measures the duration for which a device was in an active or ""on"" state" brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). @@ -785,8 +785,8 @@ brick:Temporary_Occupancy_Status,,,,,,,(deprecated),"For systems that differenti brick:Thermal_Energy_Usage_Sensor,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat -brick:Time_Parameter,,,,,,brick:Parameter,Time, -brick:Time_Setpoint,,,,,,brick:Time_Setpoint,, +brick:Time_Parameter,,,,,quantitykind:Time,brick:Parameter,, +brick:Time_Setpoint,,,,,quantitykind:Time,brick:Setpoint,, brick:Tint_Command,,,,,,brick:Command,Tint,The target level of window tint. brick:Tint_Status,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." brick:Tolerance_Parameter,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. From 1c9d227b9eb11caedfd3ee0f0b2e6ff56b321334 Mon Sep 17 00:00:00 2001 From: ektrah Date: Thu, 30 Oct 2025 15:43:30 +0100 Subject: [PATCH 27/31] Define all point attributes [no ci] --- bricksrc/points.csv | 20 ++++++++++---------- 1 file changed, 10 insertions(+), 10 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 72721907..377e79ad 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -297,7 +297,7 @@ brick:Fan_Command,,brick:Fan,,,,brick:Command,,Controls properties of fans brick:Fan_On_Off_Status,,brick:Fan,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Fan_Speed_Command,,brick:Fan,,,quantitykind:Speed,brick:Command,,Controls the speed of fans brick:Fan_Status,,brick:Fan,,,,brick:Status,,Indicates properties of fans -brick:Fault_Reset_Command,,,,,,brick:Reset_Command,Fault,Clears a fault status +brick:Fault_Reset_Command,,,,,,brick:Fault_Reset_Command,,Clears a fault status brick:Fault_Status,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter @@ -346,7 +346,7 @@ brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:T brick:High_Head_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm -brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,,The upper bound of the outside air temperature lockout range +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,Lockout,The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, @@ -440,8 +440,8 @@ brick:Load_Shed_Differential_Pressure_Setpoint,,brick:Load_Shed,,brick:Different brick:Load_Shed_Setpoint,,brick:Load_Shed,,,,brick:Setpoint,, brick:Load_Shed_Status,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect brick:Locally_On_Off_Status,,,,,,,(deprecated), -brick:Lockout_Status,,brick:Lockout,,,,brick:Status,,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" -brick:Lockout_Temperature_Differential_Parameter,,brick:Lockout,,brick:Differential,quantitykind:Temperature,brick:Parameter,, +brick:Lockout_Status,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. @@ -449,7 +449,7 @@ brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Te brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,(deprecated), brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm -brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,Lockout,The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,(deprecated), brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low @@ -602,8 +602,8 @@ brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air -brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,brick:Lockout,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,, -brick:Outside_Air_Lockout_Temperature_Setpoint,,brick:Lockout,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,, +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, @@ -623,7 +623,7 @@ brick:Parameter,,,,,,brick:Parameter,,Parameter points are configuration setting brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,brick:Sensor,,Detects pollutants in the ambient air brick:Peak_Demand_Sensor,,,,,,brick:Demand_Sensor,Peak,The peak power consumed by a process over some period of time brick:Photovoltaic_Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device -brick:PID_Parameter,,,,,,,(deprecated), +brick:PID_Parameter,,,,,,brick:PID_Parameter,, brick:Piezoelectric_Sensor,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" brick:PIR_Sensor,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors brick:PM1_Level_Sensor,,,brick:PM1.0,,,brick:Sensor,Level,Detects level of particulates of size 1 microns @@ -663,7 +663,7 @@ brick:Rated_Speed_Setpoint,,,,,,,(deprecated),Sets rated speed brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, -brick:Reheat_Command,,,,,,,(deprecated),"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Reheat_Command,,brick:Reheat,,,,brick:Command,,"A command to activate reheating, which is used for either heating or for dehumidification purposes" brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay brick:Remotely_On_Off_Status,,,,,,,(deprecated), @@ -694,7 +694,7 @@ brick:Run_Time_Sensor,,brick:Run,,,quantitykind:Time,brick:Sensor,,"Measures the brick:Sash_Position_Sensor,,,,,,brick:Sensor,Sash Position,Measures the current position of a sash in terms of the percent of fully open brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Schedule,The current setpoint as indicated by the schedule brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). -brick:Sensor_Failure_Alarm,,,,,,,(deprecated), +brick:Sensor_Failure_Alarm,,,,,,brick:Sensor_Failure_Alarm,, brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set brick:Short_Cycle_Alarm,,,,,,,(deprecated),An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle brick:Smoke_Alarm,,,brick:Smoke,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with smoke. From 3079feae5c7a22f08e84ade273e48763e831736b Mon Sep 17 00:00:00 2001 From: ektrah Date: Sat, 29 Nov 2025 09:52:20 +0100 Subject: [PATCH 28/31] Define all point attributes [no ci] --- bricksrc/points.csv | 38 +++++++++++++++++++------------------- 1 file changed, 19 insertions(+), 19 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 377e79ad..e0d5b3ac 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -113,7 +113,7 @@ brick:Core_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Core,Mea brick:Core_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." brick:Current_Imbalance_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. -brick:Current_Output_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Output,Senses the amperes of electrical current produced as output by a device +brick:Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a device brick:Current_Ratio_Setpoint,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor brick:Curtailment_Override_Command,,,,,,,(deprecated), @@ -127,10 +127,10 @@ brick:DC_Bus_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage across a DC brick:Deadband_Setpoint,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband brick:Deceleration_Time_Setpoint,,brick:Deceleration,,,quantitykind:Time,brick:Setpoint,, brick:Dehumidification_Start_Stop_Status,,brick:Dehumidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, -brick:Dehumidify_Command,,,,,,brick:Command,Dehumidify,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Dehumidify_Command,,brick:Dehumidification,,,,brick:Enable_Command,,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Deionised_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water +brick:Deionised_Water_Level_Sensor,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,brick:Alarm,,An alarm that indicates deionized water leaks. -brick:Deionized_Water_Conductivity_Sensor,,,brick:Deionized_Water,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionized water -brick:Deionized_Water_Level_Sensor,,,brick:Deionized_Water,,,brick:Sensor,Level,Measures the height/level of deionized water in some container brick:Delay_Parameter,,,,,,brick:Delay_Parameter,,A parameter determining how long to delay a subsequent action to take place after a received signal brick:Demand_Sensor,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Demand_Setpoint,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process @@ -139,11 +139,11 @@ brick:Derivative_Time_Parameter,,,,,,brick:Derivative_Time_Parameter,, brick:Dewpoint_Sensor,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor brick:Dewpoint_Setpoint,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point brick:Differential_Air_Temperature_Setpoint,,,brick:Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air -brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,brick:Differential,quantitykind:Temperature,brick:Sensor,Entering,Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,(deprecated),Measures the difference in temperature between entering and leaving water of water a circuit brick:Differential_Pressure_Deadband_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure brick:Differential_Pressure_Integral_Time_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Differential_Pressure_Load_Shed_Status,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Status,, -brick:Differential_Pressure_Proportional_Band_Parameter,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Differential_Pressure_Proportional_Band,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, brick:Differential_Pressure_Sensor,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures brick:Differential_Pressure_Setpoint,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure brick:Differential_Pressure_Setpoint_Limit,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. @@ -152,9 +152,9 @@ brick:Differential_Setpoint,,,,brick:Differential,,brick:Setpoint,,A type of Set brick:Differential_Speed_Sensor,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, brick:Differential_Speed_Setpoint,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed brick:Differential_Temperature_Setpoint,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements -brick:Direction_Command,,,,,,brick:Command,Direction,Commands that affect the direction of some phenomenon -brick:Direction_Sensor,,,,,,brick:Sensor,Direction,Measures the direction in degrees in which a phenomenon is occuring -brick:Direction_Status,,,,,,brick:Status,Direction,Indicates which direction a device is operating in +brick:Direction_Command,,,,,,,(deprecated),Commands that affect the direction of some phenomenon +brick:Direction_Sensor,,,,,,,(deprecated),Measures the direction in degrees in which a phenomenon is occuring +brick:Direction_Status,,,,,,,(deprecated),Indicates which direction a device is operating in brick:Disable_Command,,,,,,brick:Disable_Command,,Commands that disable functionality brick:Disable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Disable_Command,,Disables the use of differential enthalpy control brick:Disable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Disable_Command,,Disables the use of differential temperature control @@ -165,7 +165,7 @@ brick:Disable_Status,,,,,,brick:Disable_Status,,Indicates if functionality has b brick:Discharge_Air_Dewpoint_Sensor,,,brick:Discharge_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of discharge air brick:Discharge_Air_Differential_Pressure_Sensor,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,, brick:Discharge_Air_Differential_Pressure_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,, -brick:Discharge_Air_Duct_Pressure_Status,,,brick:Discharge_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in discharge duct is within expected bounds +brick:Discharge_Air_Duct_Pressure_Status,,,,,,,(deprecated),Indicates if air pressure in discharge duct is within expected bounds brick:Discharge_Air_Flow_Demand_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of discharge air flow required for a process brick:Discharge_Air_Flow_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, @@ -190,7 +190,7 @@ brick:Discharge_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Discharge_ brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of discharge air brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of discharge air brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint. @@ -202,7 +202,7 @@ brick:Domestic_Hot_Water_System_Enable_Command,,brick:Domestic_Hot_Water_System, brick:Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Sensor,, brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water brick:Drive_Ready_Status,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" -brick:Duct_Air_Static_Pressure_Setpoint,,,brick:Air,,quantitykind:StaticPressure,brick:Setpoint,Duct, +brick:Duct_Air_Static_Pressure_Setpoint,,,,,,,(deprecated), brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event brick:EconCycle_Start_Stop_Status,,,,,,,(deprecated), brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, @@ -370,7 +370,7 @@ brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,quantitykind:Temperature brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,brick:Sensor,Usage,"Measures the amount of hot water that is consumed, over some period of time" brick:Humidification_Start_Stop_Status,,brick:Humidification,,,brick:EnumerationKind-Start_Stop,brick:Status,, brick:Humidifier_Fault_Status,,brick:Humidifier,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier -brick:Humidify_Command,,,,,,brick:Command,Humidify, +brick:Humidify_Command,,brick:Humidification,,,,brick:Enable_Command,, brick:Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. brick:Humidity_Deadband_Setpoint,,,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity brick:Humidity_Parameter,,,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points @@ -544,7 +544,7 @@ brick:Mode_Command,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the op brick:Mode_Status,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" brick:Motion_Sensor,,,,,brick:EnumerationKind-Motion,brick:Sensor,,Detects the presence of motion in some area brick:Motor_Current_Sensor,,brick:Motor,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor -brick:Motor_Direction_Status,,brick:Motor,,,,brick:Status,Direction,"Indicates which direction a motor is operating in, e.g. forward or reverse" +brick:Motor_Direction_Status,,brick:Motor,,,brick:EnumerationKind-Forward_Reverse,brick:Status,,"Indicates which direction a motor is operating in, e.g. forward or reverse" brick:Motor_On_Off_Status,,brick:Motor,,,brick:EnumerationKind-On_Off,brick:Status,, brick:Motor_Speed_Sensor,,brick:Motor,,,quantitykind:Speed,brick:Sensor,, brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" @@ -591,8 +591,8 @@ brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,(deprecated), brick:Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" -brick:Output_Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,Output, -brick:Output_Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Output,Measures the voltage output by some process or device +brick:Output_Frequency_Sensor,,,,,,,(deprecated), +brick:Output_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage output by some process or device brick:Outside_Air_CO_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO,Measures the concentration of CO in outside air brick:Outside_Air_CO2_Sensor,,,brick:Outside_Air,,,brick:Sensor,CO2,Measures the concentration of CO2 in outside air brick:Outside_Air_Dewpoint_Sensor,,,brick:Outside_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air @@ -733,7 +733,7 @@ brick:Step_Parameter,,,,,,brick:Step_Parameter,, brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,quantitykind:DewPointTemperature,brick:Sensor,, brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit -brick:Supply_Air_Duct_Pressure_Status,,,brick:Supply_Air,,quantitykind:Pressure,brick:Status,Duct,Indicates if air pressure in supply duct is within expected bounds +brick:Supply_Air_Duct_Pressure_Status,,,,,,,(deprecated),Indicates if air pressure in supply duct is within expected bounds brick:Supply_Air_Flow_Demand_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process brick:Supply_Air_Flow_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, @@ -758,7 +758,7 @@ brick:Supply_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Supply_Air,,q brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, -brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Setpoint,Reset, +brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. @@ -854,7 +854,7 @@ brick:Water_Temperature_Alarm,,,brick:Water,,quantitykind:Temperature,brick:Alar brick:Water_Temperature_Sensor,,,brick:Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water brick:Water_Temperature_Setpoint,,,brick:Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water brick:Water_Usage_Sensor,,,brick:Water,,,brick:Sensor,Usage,"Measures the amount of water that is consumed, over some period of time" -brick:Wind_Direction_Sensor,,,brick:Wind,,,brick:Sensor,Direction,Measures the direction of wind in degrees relative to North +brick:Wind_Direction_Sensor,,,brick:Wind,,quantitykind:Azimuth,brick:Sensor,,Measures the direction of wind in degrees relative to North brick:Wind_Speed_Sensor,,,brick:Wind,,quantitykind:Speed,brick:Sensor,,"Measured speed of wind, caused by air moving from high to low pressure" brick:Zone_Air_Conditioning_Mode_Status,,,brick:Zone_Air,,brick:EnumerationKind-Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air From 07899d36dd3d1b43e750909a9a31f2f12365348f Mon Sep 17 00:00:00 2001 From: ektrah Date: Sat, 29 Nov 2025 10:12:34 +0100 Subject: [PATCH 29/31] Define all point attributes [no ci] --- bricksrc/points.csv | 56 ++++++++++++++++++++++----------------------- 1 file changed, 28 insertions(+), 28 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index e0d5b3ac..4dff70d5 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -81,7 +81,7 @@ brick:CO2_Differential_Sensor,,,brick:CO2,brick:Differential,,brick:Sensor,,Meas brick:CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Level,Measures the concentration of CO2 in air brick:CO2_Sensor,,,brick:CO2,,,brick:Sensor,,Measures properties of CO2 in air brick:CO2_Setpoint,,,brick:CO2,,,brick:Setpoint,,Sets some property of CO2 -brick:Coldest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Coldest,The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Coldest_Zone_Air_Temperature_Sensor,,,,,,,(deprecated),The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,brick:Alarm,Level,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,brick:Sensor,Level,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" @@ -204,7 +204,7 @@ brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quanti brick:Drive_Ready_Status,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" brick:Duct_Air_Static_Pressure_Setpoint,,,,,,,(deprecated), brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,,,(deprecated), +brick:EconCycle_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,EconCycle, brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, @@ -272,7 +272,7 @@ brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Tem brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance brick:Enthalpy_Setpoint,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy -brick:Even_Month_Status,,,,,,,(deprecated), +brick:Even_Month_Status,,,,,,brick:Status,Even Month, brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit @@ -322,7 +322,7 @@ brick:Generation_Sensor,,,,,,brick:Sensor,Generation,A sensor measuring how much brick:Hail_Sensor,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger_System,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. +brick:Heat_Sink_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. brick:Heating_Command,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Heating_Demand_Setpoint,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating @@ -343,7 +343,7 @@ brick:Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quant brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. brick:High_CO2_Alarm,,,brick:CO2,,,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Head_Pressure_Alarm,,,,,quantitykind:Pressure,brick:High_Alarm,Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,Lockout,The upper bound of the outside air temperature lockout range @@ -352,7 +352,7 @@ brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,(deprecated),A parameter brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm -brick:Hold_Status,,,,,,,(deprecated), +brick:Hold_Status,,,,,,brick:Status,Hold, brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, @@ -386,7 +386,7 @@ brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,bric brick:Intake_Air_Temperature_Sensor,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside brick:Integral_Gain_Parameter,,,,,,brick:Integral_Gain_Parameter,, brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,,(deprecated),Indicates the last fault code that occurred +brick:Last_Fault_Code_Status,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled brick:Lead_On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" @@ -439,27 +439,27 @@ brick:Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,,Controls load sheddin brick:Load_Shed_Differential_Pressure_Setpoint,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Load_Shed_Setpoint,,brick:Load_Shed,,,,brick:Setpoint,, brick:Load_Shed_Status,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,,,(deprecated), +brick:Locally_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Locally, brick:Lockout_Status,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" brick:Lockout_Temperature_Differential_Parameter,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Alarm,, -brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,(deprecated), +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,quantitykind:Temperature,brick:Low_Parameter,Freeze Protect, brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,Lockout,The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,(deprecated), brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Suction_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Low_Alarm,Suction,An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,, brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Alarm,, brick:Low_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. brick:Low_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:Low_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm brick:Low_Voltage_Alarm,,,,,quantitykind:Voltage,brick:Low_Alarm,,An alarm that indicates the voltage is lower than its normal state. -brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,Lowest,The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,,,,,(deprecated),The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time brick:Luminance_Alarm,,,,,quantitykind:Luminance,brick:Alarm,, brick:Luminance_Command,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system brick:Luminance_Sensor,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction @@ -551,7 +551,7 @@ brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Meas brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system +brick:No_Water_Alarm,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system brick:NO2_Level_Sensor,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area @@ -586,10 +586,10 @@ brick:On_Command,,,,,brick:On_Off-On,brick:Command,,"An On Command controls or r brick:On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" brick:On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" brick:On_Status,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" -brick:On_Timer_Sensor,,,,,,,(deprecated),"Measures the duration for which a device was in an active or ""on"" state" +brick:On_Timer_Sensor,,,,,brick:On_Off-On,brick:Sensor,Timer,"Measures the duration for which a device was in an active or ""on"" state" brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve -brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, brick:Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" brick:Output_Frequency_Sensor,,,,,,,(deprecated), brick:Output_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage output by some process or device @@ -604,7 +604,7 @@ brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumi brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, -brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,,, brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air @@ -613,7 +613,7 @@ brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,brick:Outside_Air,,quantitykind: brick:Outside_Face_Surface_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. brick:Outside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. brick:Outside_Illuminance_Sensor,,,,,quantitykind:Illuminance,brick:Sensor,Outside,"Measures the total luminous flux incident on an outside, per unit area" -brick:Overload_Alarm,,,,,,,(deprecated),An alarm that can indicate when a full-load current is exceeded. +brick:Overload_Alarm,,,,,,brick:Alarm,Overload,An alarm that can indicate when a full-load current is exceeded. brick:Overridden_Off_Status,,,,,brick:On_Off-Off,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" brick:Overridden_On_Status,,,,,brick:On_Off-On,brick:Status,Overridden,"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" brick:Overridden_Status,,,,,,brick:Status,Overridden,Indicates if the expected operating status of an equipment or control loop has been overridden @@ -624,8 +624,8 @@ brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,brick:Sensor,,Detec brick:Peak_Demand_Sensor,,,,,,brick:Demand_Sensor,Peak,The peak power consumed by a process over some period of time brick:Photovoltaic_Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device brick:PID_Parameter,,,,,,brick:PID_Parameter,, -brick:Piezoelectric_Sensor,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" -brick:PIR_Sensor,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:Piezoelectric_Sensor,,,,,,brick:Sensor,Piezoelectric,"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,brick:Sensor,PIR,Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors brick:PM1_Level_Sensor,,,brick:PM1.0,,,brick:Sensor,Level,Detects level of particulates of size 1 microns brick:PM1_Sensor,,,brick:PM1.0,,,brick:Sensor,,Detects matter of size 1 micron brick:PM10_Level_Sensor,,,brick:PM10.0,,,brick:Sensor,Level,Detects level of particulates of size 10 microns @@ -659,14 +659,14 @@ brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,quantitykind:Tem brick:Radon_Concentration_Sensor,,,brick:Rn,,quantitykind:ActivityConcentration,brick:Sensor,,Measures the concentration of radioactivity due to radon brick:Rain_Duration_Sensor,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen -brick:Rated_Speed_Setpoint,,,,,,,(deprecated),Sets rated speed +brick:Rated_Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, brick:Reheat_Command,,brick:Reheat,,,,brick:Command,,"A command to activate reheating, which is used for either heating or for dehumidification purposes" brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,,,(deprecated), +brick:Remotely_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Remotely, brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air @@ -696,7 +696,7 @@ brick:Schedule_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint, brick:Sensor,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). brick:Sensor_Failure_Alarm,,,,,,brick:Sensor_Failure_Alarm,, brick:Setpoint,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set -brick:Short_Cycle_Alarm,,,,,,,(deprecated),An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Short_Cycle_Alarm,,,,,,brick:Alarm,Short Cycle,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle brick:Smoke_Alarm,,,brick:Smoke,,,brick:Alarm,,An alarm that indicates the off-normal conditions associated with smoke. brick:Smoke_Detection_Alarm,,brick:Smoke_Detection,,,,brick:Alarm,, brick:Soil_Temperature_Sensor,,,brick:Soil,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil @@ -709,10 +709,10 @@ brick:Speed_Reset_Command,,,,,quantitykind:Speed,brick:Reset_Command,, brick:Speed_Sensor,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. -brick:Stage_Enable_Command,,,,,,,(deprecated),A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property -brick:Stages_Status,,,,,,,(deprecated),Indicates which stage a control loop or equipment is in +brick:Stage_Enable_Command,,,,,,brick:Enable_Command,Stage,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit +brick:Standby_Glycool_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Glycool Unit,Indicates the on/off status of a standby glycool unit brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, brick:Standby_Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,Standby, brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, @@ -781,7 +781,7 @@ brick:Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,,Measures tem brick:Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature brick:Temperature_Step_Parameter,,,,,quantitykind:Temperature,brick:Step_Parameter,, brick:Temperature_Tolerance_Parameter,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. -brick:Temporary_Occupancy_Status,,,,,,,(deprecated),"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Temporary_Occupancy_Status,,,,,,brick:Status,Temporary Occupancy,"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" brick:Thermal_Energy_Usage_Sensor,,,,,quantitykind:ThermalEnergy,brick:Sensor,Usage,A sensor that records the quantity of thermal energy consumed in a given period brick:Thermal_Power_Sensor,,,,,quantitykind:Power,brick:Sensor,Thermal, brick:Thermostat_Status,,brick:Thermostat,,,,brick:Status,,Status of a thermostat @@ -828,15 +828,15 @@ brick:Valve_Position_Sensor,,brick:Valve,,,,brick:Sensor,Position,Measures the c brick:Valve_Status,,brick:Valve,,,,brick:Status,,The current status of the valve. brick:Velocity_Pressure_Sensor,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure brick:Velocity_Pressure_Setpoint,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure -brick:Vent_Operating_Mode_Status,,,,,,,(deprecated),Indicates the current operating mode of a vent -brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:Vent_Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,Vent,Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Limit,Ventilation Ratio,A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. brick:VFD_Enable_Command,,brick:VFD,,,,brick:Enable_Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system brick:Voltage_Ratio_Setpoint,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object brick:Warm_Cool_Adjust_Sensor,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" -brick:Warmest_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,Warmest,The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Warmest_Zone_Air_Temperature_Sensor,,,,,,,(deprecated),The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' brick:Waste_Amount_Sensor,,,,,,,(deprecated),A metric used for measuring the quantity of waste generated in a building. brick:Water_Alarm,,,brick:Water,,,brick:Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" brick:Water_Differential_Pressure_Sensor,,,brick:Water,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. From 2bb701dba60156369f23f74020c8fd259712b2ef Mon Sep 17 00:00:00 2001 From: ektrah Date: Sun, 21 Dec 2025 11:23:55 +0100 Subject: [PATCH 30/31] Define all point attributes [no ci] --- bricksrc/points.csv | 104 ++++++++++++++++++++++---------------------- 1 file changed, 52 insertions(+), 52 deletions(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 4dff70d5..6d3b2d1c 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -114,7 +114,7 @@ brick:Core_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Core brick:Current_Imbalance_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Imbalance,A sensor which measures the current difference (imbalance) between phases of an electrical system brick:Current_Limit,,,,,quantitykind:ElectricCurrent,brick:Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. brick:Current_Output_Sensor,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a device -brick:Current_Ratio_Setpoint,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer +brick:Current_Ratio_Setpoint,,,,,,,(deprecated),Sets the ratio of currents in a transformer brick:Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor brick:Curtailment_Override_Command,,,,,,,(deprecated), brick:Cycle_Alarm,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with HVAC cycles @@ -204,7 +204,7 @@ brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,quanti brick:Drive_Ready_Status,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" brick:Duct_Air_Static_Pressure_Setpoint,,,,,,,(deprecated), brick:Duration_Sensor,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event -brick:EconCycle_Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,EconCycle, +brick:EconCycle_Start_Stop_Status,,,,,,,(deprecated), brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Effective_Setpoint,, brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, @@ -213,19 +213,19 @@ brick:Effective_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,quantitykind brick:Effective_Room_Air_Temperature_Setpoint,,,brick:Room_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, brick:Effective_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,quantitykind:Temperature,brick:Effective_Setpoint,, brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Effective_Setpoint,Target,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width -brick:Electric_Energy_Sensor,,,,,,brick:Sensor,Electric Energy, +brick:Electric_Energy_Sensor,,,,,quantitykind:Energy,brick:Sensor,Electric, brick:Electric_Power_Sensor,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed -brick:Electrical_Energy_Usage_Sensor,,,,,,brick:Sensor,Electrical Energy Usage,A sensor that records the quantity of electrical energy consumed in a given period +brick:Electrical_Energy_Usage_Sensor,,,,,quantitykind:Energy,brick:Sensor,Electric Usage,A sensor that records the quantity of electrical energy consumed in a given period brick:Embedded_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. brick:Embedded_Temperature_Setpoint,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." brick:Emergency_Air_Flow_System_Status,,brick:Emergency_Air_Flow_System,,,,brick:Status,, -brick:Emergency_Alarm,,,,,,brick:Alarm,Emergency,Alarms that indicate off-normal conditions associated with emergency systems -brick:Emergency_Generator_Alarm,,brick:Emergency_Generator,,,,brick:Alarm,,An alarm that indicates off-normal conditions associated with an emergency generator -brick:Emergency_Generator_Status,,brick:Emergency_Generator,,,,brick:Status,,Indicates if an emergency generator is active +brick:Emergency_Alarm,,,,,,,(deprecated),Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Generator_Alarm,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,,,,,,(deprecated),Indicates if an emergency generator is active brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,(deprecated), brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,(deprecated), -brick:Emergency_Power_Off_System_Status,,brick:Emergency_Power_Off_System,,,,brick:Status,, -brick:Emergency_Push_Button_Status,,,,,,brick:Status,Emergency Push Button,Indicates if an emergency button has been pushed +brick:Emergency_Power_Off_System_Status,,,,,,,(deprecated), +brick:Emergency_Push_Button_Status,,,,,,,(deprecated),Indicates if an emergency button has been pushed brick:Enable_Command,,,,,,brick:Enable_Command,,Commands that enable functionality brick:Enable_Differential_Enthalpy_Command,,,,brick:Differential,quantitykind:Enthalpy,brick:Enable_Command,,Enables the use of differential enthalpy control brick:Enable_Differential_Temperature_Command,,,,brick:Differential,quantitykind:Temperature,brick:Enable_Command,,Enables the use of differential temperature control @@ -233,9 +233,9 @@ brick:Enable_Fixed_Enthalpy_Command,,,,,quantitykind:Enthalpy,brick:Enable_Comma brick:Enable_Fixed_Temperature_Command,,,,,quantitykind:Temperature,brick:Enable_Command,Fixed,Enables the use of fixed temperature control brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,brick:Hot_Water_System,brick:Outside_Air,,quantitykind:Temperature,brick:Enable_Setpoint,,Enables hot water system when outside air temperature reaches the indicated value brick:Enable_Status,,,,,,brick:Enable_Status,,Indicates if a system or piece of functionality has been enabled -brick:Energy_Generation_Sensor,,,,,,brick:Sensor,Energy Generation,A sensor measuring the amount of generated energy. -brick:Energy_Sensor,,,,,,brick:Sensor,Energy,Measures energy consumption -brick:Energy_Usage_Sensor,,,,,,brick:Sensor,Energy Usage,Measures the total amount of energy used over some period of time +brick:Energy_Generation_Sensor,,,,,quantitykind:Energy,brick:Sensor,Generation,A sensor measuring the amount of generated energy. +brick:Energy_Sensor,,,,,quantitykind:Energy,brick:Sensor,,Measures energy consumption +brick:Energy_Usage_Sensor,,,,,quantitykind:Energy,brick:Sensor,Usage,Measures the total amount of energy used over some period of time brick:Entering_Chilled_Water_Flow_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water brick:Entering_Chilled_Water_Flow_Setpoint,,,brick:Entering_Chilled_Water,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water brick:Entering_Chilled_Water_Temperature_Sensor,,,brick:Entering_Chilled_Water,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is enteringed to a cooling tower @@ -272,7 +272,7 @@ brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,quantitykind:Tem brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water brick:Enthalpy_Sensor,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance brick:Enthalpy_Setpoint,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy -brick:Even_Month_Status,,,,,,brick:Status,Even Month, +brick:Even_Month_Status,,,,,,,(deprecated), brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit @@ -282,11 +282,11 @@ brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,b brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air -brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,Stack,Sets the size of a deadband of exhaust air stack flow -brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,Stack, -brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,Stack, -brick:Exhaust_Air_Stack_Flow_Sensor,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Sensor,Stack,Measures the rate of flow of air in the exhaust air stack -brick:Exhaust_Air_Stack_Flow_Setpoint,,,brick:Exhaust_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,Stack,Sets exhaust air stack flow rate +brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of exhaust air stack flow +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Stack_Flow_Sensor,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in the exhaust air stack +brick:Exhaust_Air_Stack_Flow_Setpoint,,brick:Exhaust_Air_Stack,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air stack flow rate brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air @@ -308,7 +308,7 @@ brick:Fire_Sensor,,,brick:Fire,,,brick:Sensor,,Measures the presence of fire brick:Flow_Sensor,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance brick:Flow_Setpoint,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow brick:Formaldehyde_Level_Sensor,,,brick:CH2O,,,brick:Sensor,Level,Measures the concentration of formaldehyde in air -brick:Freeze_Status,,,,,,brick:Status,Freeze,Indicates if a substance contained within a vessel has frozen +brick:Freeze_Status,,,,,,,(deprecated),Indicates if a substance contained within a vessel has frozen brick:Frequency_Command,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) brick:Frequency_Sensor,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" brick:Frequency_Setpoint,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency @@ -322,7 +322,7 @@ brick:Generation_Sensor,,,,,,brick:Sensor,Generation,A sensor measuring how much brick:Hail_Sensor,,,brick:Hail,,,brick:Sensor,,Measures hail in terms of its size and damage potential brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,quantitykind:Temperature,brick:Sensor,, brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger_System,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled -brick:Heat_Sink_Temperature_Sensor,,,,,quantitykind:Temperature,brick:Sensor,Heat Sink,Measure temperature of the heat sink on a device such as a VFD. +brick:Heat_Sink_Temperature_Sensor,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. brick:Heating_Command,,brick:Heating,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) brick:Heating_Demand_Sensor,,brick:Heating,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton brick:Heating_Demand_Setpoint,,brick:Heating,,,,brick:Demand_Setpoint,,Sets the rate required for heating @@ -343,16 +343,16 @@ brick:Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quant brick:High_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. brick:High_CO2_Alarm,,,brick:CO2,,,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that discharge air temperature is too high -brick:High_Head_Pressure_Alarm,,,,,quantitykind:Pressure,brick:High_Alarm,Head,An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Head_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. brick:High_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. brick:High_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm -brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:High_Parameter,Lockout,The upper bound of the outside air temperature lockout range +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated),The upper bound of the outside air temperature lockout range brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:High_Alarm,, brick:High_Temperature_Alarm,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. brick:High_Temperature_Alarm_Parameter,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm -brick:Hold_Status,,,,,,brick:Status,Hold, +brick:Hold_Status,,,,,,,(deprecated), brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,brick:Load_Shed,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Reset_Status,, @@ -386,7 +386,7 @@ brick:Inside_Face_Surface_Temperature_Setpoint,,,,,quantitykind:Temperature,bric brick:Intake_Air_Temperature_Sensor,,,brick:Intake_Air,,quantitykind:Temperature,brick:Sensor,,Measures air at the interface between the building and the outside brick:Integral_Gain_Parameter,,,,,,brick:Integral_Gain_Parameter,, brick:Integral_Time_Parameter,,,,,,brick:Integral_Time_Parameter,, -brick:Last_Fault_Code_Status,,,,,,brick:Status,Last Fault Code,Indicates the last fault code that occurred +brick:Last_Fault_Code_Status,,,,,,,(deprecated),Indicates the last fault code that occurred brick:Lead_Lag_Command,,,,,,brick:Command,Lead Lag,Enables lead/lag operation brick:Lead_Lag_Status,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled brick:Lead_On_Off_Command,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" @@ -432,28 +432,28 @@ brick:Lighting_Correlated_Color_Temperature_Sensor,,brick:Lighting,,,quantitykin brick:Lighting_Level_Command,,brick:Lighting,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. brick:Limit,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point brick:Liquid_Detection_Alarm,,brick:Liquid_Detection,,,,brick:Alarm,, -brick:Load_Current_Sensor,,,,,quantitykind:ElectricCurrent,brick:Sensor,Load,Measures the current consumed by a load -brick:Load_Parameter,,,,,,brick:Parameter,Load, -brick:Load_Setpoint,,,,,,brick:Setpoint,Load, +brick:Load_Current_Sensor,,,,,,,(deprecated),Measures the current consumed by a load +brick:Load_Parameter,,,,,,,(deprecated), +brick:Load_Setpoint,,,,,,,(deprecated), brick:Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,,Controls load shedding behavior provided by a control system brick:Load_Shed_Differential_Pressure_Setpoint,,brick:Load_Shed,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, brick:Load_Shed_Setpoint,,brick:Load_Shed,,,,brick:Setpoint,, brick:Load_Shed_Status,,brick:Load_Shed,,,,brick:Status,,Indicates if a load shedding policy is in effect -brick:Locally_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Locally, -brick:Lockout_Status,,,,,,brick:Status,Lockout,"Indicates if a piece of equipment, system, or functionality has been locked out from operation" -brick:Lockout_Temperature_Differential_Parameter,,,,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, +brick:Locally_On_Off_Status,,,,,,,(deprecated), +brick:Lockout_Status,,,,,,,(deprecated),"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated), brick:Low_Air_Flow_Alarm,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. brick:Low_Battery_Alarm,,brick:Battery,,,,brick:Low_Alarm,,An alarm that indicates the battery is low. brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the discharge air flow is lower than normal. brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,quantitykind:Temperature,brick:Low_Alarm,, -brick:Low_Freeze_Protect_Temperature_Parameter,,,,,quantitykind:Temperature,brick:Low_Parameter,Freeze Protect, +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,(deprecated), brick:Low_Humidity_Alarm,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. brick:Low_Humidity_Alarm_Parameter,,,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm -brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Low_Parameter,Lockout,The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated),The lower bound of the outside air temperature lockout range brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,(deprecated), brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low -brick:Low_Suction_Pressure_Alarm,,,,,quantitykind:Pressure,brick:Low_Alarm,Suction,An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Suction_Pressure_Alarm,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Low_Alarm,, brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,quantitykind:Temperature,brick:Low_Alarm,, brick:Low_Temperature_Alarm,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. @@ -465,7 +465,7 @@ brick:Luminance_Command,,,,,quantitykind:Luminance,brick:Command,,Controls the a brick:Luminance_Sensor,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction brick:Luminance_Setpoint,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance brick:Maintenance_Mode_Command,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" -brick:Maintenance_Required_Alarm,,,,,,brick:Alarm,Maintenance Required,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Maintenance_Required_Alarm,,,,,brick:EnumerationKind-Maintenance_Required,brick:Alarm,,An alarm that indicates that repair/maintenance is required on an associated device or equipment brick:Manual_Auto_Status,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation brick:Max_Air_Flow_Setpoint_Limit,,,brick:Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. brick:Max_Air_Temperature_Setpoint,,,brick:Air,,quantitykind:Temperature,brick:Max_Setpoint,,Setpoint for maximum air temperature @@ -480,7 +480,7 @@ brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Dischar brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. brick:Max_Limit,,,,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. -brick:Max_Load_Setpoint,,,,,,brick:Max_Setpoint,Load, +brick:Max_Load_Setpoint,,,,,,,(deprecated), brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. @@ -517,7 +517,7 @@ brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Dischar brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. brick:Min_Limit,,,,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. -brick:Min_Load_Setpoint,,,,,,brick:Min_Setpoint,Load, +brick:Min_Load_Setpoint,,,,,,,(deprecated), brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint. brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint. @@ -551,7 +551,7 @@ brick:Motor_Torque_Sensor,,brick:Motor,,,quantitykind:Torque,brick:Sensor,,"Meas brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,brick:Sensor,Usage,"Measures the amount of natural gas that is consumed or used, over some period of time" -brick:No_Water_Alarm,,,brick:Water,,,brick:Alarm,No,Alarm indicating that there is no water in the equipment or system +brick:No_Water_Alarm,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system brick:NO2_Level_Sensor,,,brick:NO2,,,brick:Sensor,Level,Measures the concentration of NO2 in air brick:Occupancy_Command,,,,,,brick:Command,Occupancy,"Controls whether or not a device or controller is operating in ""Occupied"" mode" brick:Occupancy_Count_Sensor,,,,,quantitykind:Count,brick:Sensor,Occupancy,Sensors measuring the number of people in an area @@ -589,7 +589,7 @@ brick:On_Status,,,,,brick:On_Off-On,brick:Status,,"Indicates if a control loop, brick:On_Timer_Sensor,,,,,brick:On_Off-On,brick:Sensor,Timer,"Measures the duration for which a device was in an active or ""on"" state" brick:Open_Close_Command,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" brick:Open_Close_Status,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve -brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,brick:Heating_Valve,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Open, +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,(deprecated), brick:Operating_Mode_Status,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" brick:Output_Frequency_Sensor,,,,,,,(deprecated), brick:Output_Voltage_Sensor,,,,,,,(deprecated),Measures the voltage output by some process or device @@ -602,9 +602,9 @@ brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,quantitykind:VolumeFlowRate brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,brick:Sensor,Grains,Measures the mass of water vapor in outside air brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air -brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,brick:Parameter,Lockout, -brick:Outside_Air_Lockout_Temperature_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Setpoint,Lockout, -brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,brick:Outside_Air,brick:Differential,quantitykind:Temperature,,, +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,(deprecated), +brick:Outside_Air_Lockout_Temperature_Setpoint,,,,,,,(deprecated), +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,(deprecated), brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:High_Reset_Setpoint,, brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air @@ -660,13 +660,13 @@ brick:Radon_Concentration_Sensor,,,brick:Rn,,quantitykind:ActivityConcentration, brick:Rain_Duration_Sensor,,,brick:Rain,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame brick:Rain_Level_Sensor,,,brick:Rain,,,brick:Sensor,Level,Measures the amount of precipitation fallen brick:Rated_Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,Rated,Sets rated speed -brick:Reactive_Energy_Sensor,,,,,,brick:Sensor,Reactive Energy,Measures the integral of reactive power +brick:Reactive_Energy_Sensor,,,,,quantitykind:Energy,brick:Sensor,Reactive,Measures the integral of reactive power brick:Reactive_Power_Sensor,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,brick:Sensor,Level, brick:Reheat_Command,,brick:Reheat,,,,brick:Command,,"A command to activate reheating, which is used for either heating or for dehumidification purposes" brick:Relative_Humidity_Sensor,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature brick:Relay_Command,,brick:Relay,,,,brick:Command,,Commands to switch the relay -brick:Remotely_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Remotely, +brick:Remotely_On_Off_Status,,,,,,,(deprecated), brick:Reset_Command,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" brick:Reset_Setpoint,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies brick:Return_Air_CO_Sensor,,,brick:Return_Air,,,brick:Sensor,CO,Measures the concentration of CO in return air @@ -711,12 +711,12 @@ brick:Speed_Setpoint,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed brick:Speed_Setpoint_Limit,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. brick:Stage_Enable_Command,,,,,,brick:Enable_Command,Stage,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property brick:Stages_Status,,,,,,brick:Status,Stages,Indicates which stage a control loop or equipment is in -brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Glycool_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Glycool Unit,Indicates the on/off status of a standby glycool unit -brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby, -brick:Standby_Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,Standby, -brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,quantitykind:Temperature,brick:Setpoint,Standby Target, -brick:Standby_Unit_On_Off_Status,,,,,brick:EnumerationKind-On_Off,brick:Status,Standby Unit,Indicates the on/off status of a standby unit +brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit +brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Standby_Load_Shed_Command,,,,,,,(deprecated), +brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,,,,(deprecated), +brick:Standby_Unit_On_Off_Status,,,,,,,(deprecated),Indicates the on/off status of a standby unit brick:Start_Stop_Command,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence brick:Start_Stop_Status,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) brick:Static_Pressure_Deadband_Setpoint,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure @@ -796,7 +796,7 @@ brick:TVOC_Sensor,,,brick:VOC,,,brick:Sensor,, brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air -brick:Unit_Failure_Alarm,,,,,,brick:Failure_Alarm,Unit,An alarm that indicates the failure of an equipment or device +brick:Unit_Failure_Alarm,,,,,,,(deprecated),An alarm that indicates the failure of an equipment or device brick:Unoccupied_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Air,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets discharge air flow for cooling when unoccupied brick:Unoccupied_Cooling_Mode_Status,brick:Unoccupied,brick:Cooling,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" @@ -833,7 +833,7 @@ brick:Ventilation_Air_Flow_Ratio_Limit,,,brick:Air,,quantitykind:VolumeFlowRate, brick:VFD_Enable_Command,,brick:VFD,,,,brick:Enable_Command,,Enables operation of a variable frequency drive brick:Voltage_Alarm,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. brick:Voltage_Imbalance_Sensor,,,,,quantitykind:Voltage,brick:Sensor,Imbalance,A sensor which measures the voltage difference (imbalance) between phases of an electrical system -brick:Voltage_Ratio_Setpoint,,,,,quantitykind:Voltage,brick:Setpoint,Ratio,Sets the ratio of voltage in a transformer +brick:Voltage_Ratio_Setpoint,,,,,,,(deprecated),Sets the ratio of voltage in a transformer brick:Voltage_Sensor,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object brick:Warm_Cool_Adjust_Sensor,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" brick:Warmest_Zone_Air_Temperature_Sensor,,,,,,,(deprecated),The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' @@ -863,5 +863,5 @@ brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,quantitykind:RelativeHumidity brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone brick:Zone_CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone brick:Zone_Occupied_Load_Shed_Command,brick:Occupied,brick:Load_Shed,,,,brick:Command,Zone, -brick:Zone_Standby_Load_Shed_Command,,brick:Load_Shed,,,,brick:Command,Zone Standby, +brick:Zone_Standby_Load_Shed_Command,,,,,,,(deprecated), brick:Zone_Unoccupied_Load_Shed_Command,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,Zone, From dacfbb0d1f17cea97376bc2ab1f319cbf77a6335 Mon Sep 17 00:00:00 2001 From: ektrah Date: Sun, 21 Dec 2025 11:33:29 +0100 Subject: [PATCH 31/31] Define all point attributes [no ci] --- bricksrc/points.csv | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/bricksrc/points.csv b/bricksrc/points.csv index 6d3b2d1c..d1fdb40f 100644 --- a/bricksrc/points.csv +++ b/bricksrc/points.csv @@ -861,7 +861,7 @@ brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,quantitykind:DewPointTemperatur brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone -brick:Zone_CO2_Level_Sensor,,,brick:CO2,,,brick:Sensor,Zone Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone +brick:Zone_CO2_Level_Sensor,,,brick:Zone_Air,,,brick:Sensor,CO2 Level,A physical or virtual sensor which represents the CO2 level of an HVAC Zone brick:Zone_Occupied_Load_Shed_Command,brick:Occupied,brick:Load_Shed,,,,brick:Command,Zone, brick:Zone_Standby_Load_Shed_Command,,,,,,,(deprecated), brick:Zone_Unoccupied_Load_Shed_Command,brick:Unoccupied,brick:Load_Shed,,,,brick:Command,Zone,