Skip to content

Wrong units in comment of variable pstd in icarus.F90 #145

@mo-abodas

Description

@mo-abodas

Variable pstd in icarus seems to have the wrong units in the associated comment: L53

It seems that pressures in icarus are in dyne/cm2, according to a comment in the icarus code in COSP1:

!press and dpress are dyne/cm2 = Pascals *10

The fact that variables press and dpress are multiplied by 10 supports the conclusion that the comment has the wrong units.

Thanks to Stephan H for finding this inconsistency.