Skip to content

static_list_var can't be in scientific notation #2

@glucksfall

Description

@glucksfall

Hello everyone,

I found that using scientific notation (e.g. 1.567668E+00) in a static_list_var impedes BNF to proceed beyond the first population. The error is something about BNF can't find parameters in 1_summary_diff.txt

Best regards