Skip to content

MQTT parsing error shelly1pluspm #70

@GregoryDC

Description

@GregoryDC

example MQTT info:
topic: "shellies/shellyplus1pm-3083980a70ac/status/switch:0"
payload: "{"id":0, "source":"init", "output":true, "apower":291.5, "voltage":226.5, "current":1.437, "aenergy":{"total":80.415,"by_minute":[3619.099,4730.434,4729.123],"minute_ts":1652655284},"temperature":{"tC":63.2, "tF":145.7}}"

RPC notifications disabled in Shelly config.

resulting in the following errors in HA logs:
2022-05-16 08:57:59 ERROR (Thread-9) [pyShelly] Error parsing MQTT message, Client, shellies/shellyplus1pm-3083980a70ac/status/switch:0
Traceback (most recent call last):
File "/usr/local/lib/python3.9/site-packages/pyShelly/mqtt.py", line 64, in receive_msg
self._root.update_block(device_id,
File "/usr/local/lib/python3.9/site-packages/pyShelly/init.py", line 355, in update_block
block.update_mqtt(payload)
File "/usr/local/lib/python3.9/site-packages/pyShelly/block.py", line 169, in update_mqtt
data = data['params'] if 'params' in data else data['result']
KeyError: 'result'

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions