using a hard drive connector for heater/bed could be dangerous switch for atx +4 12 connector  #10

@terramir

Description

@terramir

the one wire that carries 12V is too much constant current to be safe I already burned the wire twice lost one connector on both the psu and board, if you replace the hd connector with the 12V cpu 4 pin connector you halve the current per wire and hence ensure the wire does not burn up and the atx +4 cpu connector is made to handle quite a bit more that 10A @12v it actually can handle a max of around 12A per contact, and if you can find gold plated ones even 13A per contact. using the hard disk connector in future will cause problems not just for me. it can cause a fire hazard for anyone. should be a 5 min job to change the connector on the pcb layout they connector has a 4.2 mm pitch and it would solve alot of problems