Skip to content

Detector angles not read from Velox .emd files #4

@dtlalexander

Description

@dtlalexander

When loading .emd files using hyperspy and then working with them in espm, it seems that the EDX detector angles (elevation, azimuth) are not read. Hyperspy sets the elevation to a default value of 35 degrees and azimuth of 0 degrees. When going to espm, the default values are instead 22 degrees elevation and 0 degrees azimuth. I can use set_analysis_parameters to set the correct values*, but in principle it should be possible to read the correct values from the .emd files since they are in the original_metadata. Might be more a hyperspy issue than espm?

*For SuperX G2, elevation angle is 18 degrees, and azimuths are respectively 45, 135, 225, 315 degrees for the four different detectors.

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't working

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions