Hey all,

I noticed that the input wwt_temp_inc quickly has a large impact on the N2O emissions from sludge incineration (changes drastically between 1023 K and 1223 K). Also, 1023 is automatically filled in when one selects yes for sludge is sent to incinerate. In my case, this led to a gross overestimation of N2O. It would be great if this was present in the description of the input so that users are aware that it has a large impact and that just taking the "default" value is not a great idea in this case.