Notifications
You must be signed in to change notification settings - Fork 50
Open
Description
When run unit test, it will give following error:
Child was terminated by signal 1
Traceback (most recent call last):
File "C:\Users\JIANJU~1\AppData\Local\Temp\tmp-Buildings-1-i6ps1sdj/./run.py", line 106, in <module>
run_Buildings_Controls_OBC_CDL_Continuous_Validation_Acos()
File "C:\Users\JIANJU~1\AppData\Local\Temp\tmp-Buildings-1-i6ps1sdj/./run.py", line 3, in run_Buildings_Controls_OBC_CDL_Continuous_Validation_Acos
import Buildings_Controls_OBC_CDL_Continuous_Validation_Acos as m
File "C:\Users\JIANJU~1\AppData\Local\Temp\tmp-Buildings-1-i6ps1sdj\Buildings_Controls_OBC_CDL_Continuous_Validation_Acos.py", line 45
worDir = "C:\Users\JIANJU~1\AppData\Local\Temp\tmp-Buildings-1-i6ps1sdj\Buildings"
^
SyntaxError: (unicode error) 'unicodeescape' codec can't decode bytes in position 2-3: truncated \UXXXXXXXX escape
This error occurs when putting a backslash and U (\U) characters in the worDir string, which gets interpreted as the start of Unicode bytes.
See the solution in https://sebhastian.com/syntaxerror-unicode-error-unicodeescape-codec-cant-decode-bytes-in-position-2-3-truncated-escape/
Metadata
Metadata
Assignees
Labels
No labels