Skip to content

semp-tcp.py issue #28

@git3smurf

Description

@git3smurf

When I run semp-tcp.py i get this error:

root@SEmeterproxy:/solaredge_meterproxy# python3 semp-tcp.py -v
2023-05-13 10:56:28 WARNING: No meters defined in semp-tcp.conf
Traceback (most recent call last):
File "semp-tcp.py", line 256, in
server = StartTcpServer(
TypeError: StartTcpServer() got an unexpected keyword argument 'framer'
root@SEmeterproxy:/solaredge_meterproxy#

this is my configuration file (semp-tcp.conf)
server]

Serving IP address.

optional, default: all interfaces

address = "192.168.40.70"

Serving port.

optional, default: 5502

#port = 4196

Modbus frame type, set to rtu for Modbus RTU over TCP

optional, default: socket

#framer = socket
framer = "rtu"

Logging level, CRITICAL, ERROR, WARNING, INFO, DEBUG

optional, default: INFO

log_level = DEBUG

Masqueraded meters, comma separated.

optional, default: ''

#meters = meter1, meter2

Meters defined in [server] need a config section, one per meter.

Depending on the type of meter that is to be masqueraded, you can

define a number of generic and type specific variables.

Modbus address of the meter as defined in the SolarEdge inverter.

This value needs to be unique.

optional, default: 2

#dst_address = 2

Source meter type, which corresponds to a script in /devices.

The generic.py device returns null values.

optional, default: generic

#type = generic

Masqueraded serial number.

Need not be correct, must be unique, must be an integer.

optional, default: 987654

#serial_number = 987654

Current transformer amperage rating.

optional, default: 5

ct_current = 10

Current transformer direction inversion, set to 1 if required.

optional, default: 0

#ct_inverted = 0

Offset between phases, set to 0, 90, 120 or 180.

optional, default: 0

#phase_offset = 120

Number of seconds between value refreshes.

It also mentions "no meters defined" while on default ... but when I set meters = meter1 in semp-tcp.conf I get this...

root@SEmeterproxy:/solaredge_meterproxy# python3 semp-tcp.py -v
Traceback (most recent call last):
File "semp-tcp.py", line 153, in
address = confparser[meter].getint("dst_address", fallback=default_config["meters"]["dst_address"])
File "/usr/lib/python3.8/configparser.py", line 960, in getitem
raise KeyError(key)
KeyError: 'meter1'
root@SEmeterproxy:/solaredge_meterproxy#

Then it hangs on line 153 ...