@@ -3265,7 +3265,9 @@ MaxAuxilaryChargingRate and EmergencyResChargingRate.
32653265 Speeds up emergency application along the entire train. (default 0)
32663266- ``Wagon(ORTSEmergencyResQuickRelease `` -- Set to 1 (default 0) to enable quick release,
32673267 in which emergency reservoir air is used to increase the brake pipe pressure
3268- during release. Remains active until aux res has recharged.
3268+ during release. Remains active until aux res has recharged. For systems with a
3269+ dedicated quick release reservoir but without higher brake cylinder pressure in
3270+ emergency, set this to 2 to disable use of the emergency res for brake cylinder pressure.
32693271- ``Wagon(ORTSMainResPipeAuxResCharging `` -- Boolean value that indicates,
32703272 for twin pipe systems, if the main reservoir pipe is used for charging the auxiliary
32713273 reservoirs. Alternately, if equipped with a supply reservoir, the supply reservoir
@@ -3335,11 +3337,11 @@ MaxAuxilaryChargingRate and EmergencyResChargingRate.
33353337 cylinder pressure reaches the pressure specified here (default 0,
33363338 which disables quick service).
33373339- ``Wagon(ORTSQuickServiceApplicationRate `` -- Optional setting for brake cylinder
3338- application rate during quick service, can be used to increase speed of initial
3340+ application rate used during quick service, can be used to increase speed of initial
33393341 applications. Has no effect if set lower than ``MaxApplicationRate `` (default 0).
3340- - ``Wagon(ORTSQuickServiceVentRate `` -- Optional ability for the brake pipe
3341- pressure to be locally reduced at the specified rate while quick service is active
3342- (default 0).
3342+ - ``Wagon(ORTSQuickServiceVentRate `` -- Dramatically speeds up propagation of initial
3343+ applications by venting the wagon brake pipe pressure at the specified rate until
3344+ an initial application has been established (default 0).
33433345- ``Wagon(ORTSAcceleratedApplicationFactor `` -- Triple valves can speed up applications
33443346 by measuring the rate of brake pipe reduction, multiplying the reduction
33453347 by the factor specified here, then locally venting that amount of brake pipe air.
0 commit comments