Skip to content

Documentation enhancement - setup #14

@austrisv

Description

@austrisv

Two suggestions.

First - either in software setup or Hardware - setting up the ESP, where it talks about voltage divider

Fine tune vadjust value - test Voltage from panel using multimeter.

  • using the serial monitor "vadjust ##" so the involt matches
  • using the curl  curl mppt.local --data "vadjust=##"
  • don't forget save afterwards - so it gets picked up upon restart

Second - Hardware Build
Setting up the PSU
amend/update with instruction to enable "auto-output"
Keep pressing "SET" to enter parameter setting interface; press "Up" to adjust to "-F2-". Then press "OK" and it will display "Yo-0". Switch it to "Yo-1" by pressing "Up". Press "OK" to store the setting. 

Metadata

Metadata

Assignees

No one assigned

    Labels

    documentationImprovements or additions to documentation

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions