Notifications
You must be signed in to change notification settings - Fork 6
Settings Flags
Flags for the settings file
-
/path/to/output/:outdir; output directory (This should written at the first line in this file!!)
-
/path/to/input/:indir; input directory (ignored unless restart)
-
PIP:flag_eqs; flag_for equation: HD (hydrodynamics), MHD (magnetohydrodynamics) and PIP (partially-ionised plasma)
-
-1:flag_restart; restart count (-1:no restart, 0: restart. nout at the end of config.txt will be read, >0: restart from No."flag_restart" data)
-
1:ndim; dimension (If you try debug_direction of >1, then you need to set ndim to 2 or 3)
-
128000:ix; grid number for x-direction
-
2:jx; grid number for y-direction (minimum of 2?)
-
2:kx; grid number for z-direction (minimum of 2?)
-
10.0 :dtout; output period. Based on characteristic times of the simulation parameters.
-
1000.0:tend; end time for simulation (if lt 0 then default value is set)
-
0 :flag_cyl; set to 1 when you use Cylindrical coordinates (x=>r,y=>z,z=>phi) NB: Only ndim=2 is allowed (rz-plane)
-
5.0 :gm_d; Gas constant numerator
-
3.0 :gm_n; Gas constant denominator
-
0.8 :safety; safety factor
-
shock_tube:flag_ini; flag for initial setting
-
0:flag_sch; flag for numerical scheme (0:HLL-branch, 1:SLW)
-
2:flag_hll; flag for HLL branch (0:HLL,1:Rusanov,2:HLLD)
-
2:s_order; order of space for HLL branch (1, 2)
-
0:flag_time; flag for time integration method (0:RK, 1: SSPRK)
-
2:t_order; order of time (2 or 3. Activated ONLY WHEN flag_time=1)
-
0:flag_grav; flag for gravity
-
-1:flag_artvis; flag for artificial viscosity (default :-1)
-
1.8:theta; parameter for artificial viscosity (set between 1 and 2 inclusive)
===For limits===;
-
0.00000001 :ro_lim; Lower limit for density
-
0.00000001 :pr_lim; Lower limit for pressure
===For Boundary conditions===;
-
-1 :flag_bnd_x_l; flag for x-boundary (if 0 then default value is set)
-
-1 :flag_bnd_x_r; flag for x+boundary (if 0 then default value is set)
-
-1 :flag_bnd_y_l; flag for y-boundary (if 0 then default value is set)
-
-1 :flag_bnd_y_r; flag for y+boundary (if 0 then default value is set)
-
-1 :flag_bnd_z_l; flag for z-boundary (if 0 then default value is set)
-
-1 :flag_bnd_z_r; flag for z+boundary (if 0 then default value is set)
===For MHD===;
-
0.1:beta; initial plasma beta
-
0:flag_amb; flag for resistive of not (Ambipolar?)
-
1:flag_divb; flag for divB cleaning (0: no cleaning, 1:9-wave, 2:iterative 9-wave)
-
0.7 :db_clean; paramter for divb cleaning
-
0.1 :b_cr; paramter for divb cleaning
===For Resistivity===;
-
0:flag_resi; flag for resistive of not (1:uniform, 11: fixed localized, 22: anomalous (J dependent), 32: anomalous (vd dependent))
-
0.1:eta_0; resistivity
-
1.0:j_cri; critical current density (for J-dependent anomalous res)
-
100.0:vd_cri; critical drift velocity (for vd-dependent anomalous res)
===For Two fluid=====;
-
0.9:n_fraction; for uniform ionization degree
-
1.0:col;for collisional coefficient
-
0 :flag_pip_imp;for implicit scheme in source term
-
10.0 :pip_imp_factor;cfl condition factor for pip_implicit scheme
-
1 :flag_col;flag for collisional coefficient. Possible values: 1 (collisions that don't depend on temperature), 2 (thermal collisions, Alfven speed normalised), 3 (thermal collisions, sound speed normalised), 4 (thermal + velocity drift collisions, Alfven speed normalised), 5 (thermal + velocity drift collisions, sound speed normalised).
-
0:flag_IR;flag for ionization and recombination
-
5d0:t_IR;time scale of ionization and recombination
==For heat condution===;
0 :flag_heat;heat conduction flag (0:switch-off, 1:switch-on)
1 :hc_type; type of heat conduction (0:constant-type, 1:Spitzer-type)
2 :hc_integ; time integration (0:explicit, 1:implicit, 2:2nd-order super timestepping, 3:subcycling)
2 :hc_split;region splitting method for the implicit method (1:Yokoyama-Shibata, 2:Takasao+2015)
0.3:safety_cnd; safety factor for heat conduction (not used in implicit method)
30:nsub_max; Max subcycle number for super timestepping and Subcycling. Solutions go wrong with nsub > 40
2 :hc_sch; iterative method for heat conduction equation (1:SOR, 2:BICG)
8.2:kapper; heat condution coefficient (Note: One should be careful about your normalization unit)
500:hc_max; maximum iteration count for heat conduction
1.0:sor_omega; SOR-omega parameter (for iterative method)
==For MPI====;
1 :flag_mpi;flag for mpi
1 :mpi_x;node number for x-direction
1 :mpi_y;node number for y-direction
1 :mpi_z;node number for z-direction
1 :flag_mpi_split;flag for splitting domain (Activated ONLY WHEN A=mpi_xmpi_ympi_z=0 or A ne total_prc)
==For debug==;
0 :flag_debug; flag for debug (Currently not used)
0 :debug_option;option for debug
=== NOTE: if you try debug_direction of >1, then you need to set ndim to 2 or 3. ===;
1:debug_direction;direction for debug (1:x, 2:y, 3:z, ...)
0.494:debug_parameter;debug parameter
0:no_advection;neglect advection term of induction equation
==For damping==
0 :flag_damp; flag for damping
0.0 :damp_time; timescale for damping