217 changes: 217 additions & 0 deletions example_code/ecl_timesync.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,217 @@
#!/usr/bin/env python3
"""
Danfoss ECL Time Syncing Script
Sets the current date and time on the Danfoss ECL controller via Modbus
Tested on ECL110.

Vibe-coded using Claude Sonnet 4 2025-09-28

"""

from pymodbus.client import ModbusSerialClient
from pymodbus.exceptions import ModbusException
from pymodbus.pdu import ExceptionResponse
from datetime import datetime
import time
import sys


SERIAL_PORT = '/dev/ttyUSB0' # USB to RS485 adapter port
MB_ID = 5 # 5 is a danfoss standard id

# Standard comm parameters
BAUD_RATE = 19200
DATA_BITS = 8
PARITY = 'E' # Even
STOP_BITS = 1

# Danfoss ECL Date/Time register addresses
TIME_REGISTERS = {
'hour': 64045, # Hour (0-23)
'minute': 64046, # Minute (0-59)
'day': 64047, # Day (1-31)
'month': 64048, # Month (1-12)
'year': 64049, # Year (e.g., 2025)
}

def write_register(client, address, value, mb_id):
"""Write a single register to the Danfoss ECL"""
try:
# Use 0-based addressing (subtract 1 from PNU address)
modbus_address = address - 1
response = client.write_register(address=modbus_address, value=value, slave=mb_id)

if isinstance(response, ExceptionResponse):
return False, f"Unable to write - {response}"
else:
return True, "Success"

except Exception as e:
return False, f"Error: {e}"

def set_ecl_time(client, mb_id, target_datetime=None):
"""Set the Danfoss ECL date and time"""
if target_datetime is None:
target_datetime = datetime.now()

print(f"Setting Danfoss ECL time to: {target_datetime.strftime('%Y-%m-%d %H:%M')}")
print()

# Warning and confirmation
print("⚠️ You are about to write to Modbus registers on the Danfoss ECL")
print("This will modify the following registers with the values:")

# Prepare the values to write
# Note: Danfoss ECL year register only stores 2-digit year (e.g., 25 for 2025)
time_values = {
'hour': target_datetime.hour,
'minute': target_datetime.minute,
'day': target_datetime.day,
'month': target_datetime.month,
'year': target_datetime.year % 100, # Convert to 2-digit year
}

# Show what will be written
for register_name, value in time_values.items():
address = TIME_REGISTERS[register_name]
if register_name == 'year':
print(f" • Register {address} ({register_name.capitalize()}): {value} (20{value:02d})")
else:
print(f" • Register {address} ({register_name.capitalize()}): {value}")

print()

# Ask for confirmation
confirm = input("Do you want to proceed with writing to these registers? (yes/no): ").lower().strip()
if confirm not in ['yes', 'y']:
print("Operation cancelled by user.")
return False

print()
print("Proceeding with register writes...")
print()

# Write each register
all_success = True
for register_name, value in time_values.items():
address = TIME_REGISTERS[register_name]
success, message = write_register(client, address, value, mb_id)

if success:
if register_name == 'year':
print(f"✓ {register_name.capitalize()}: {value} (20{value:02d}) -> Register {address}")
else:
print(f"✓ {register_name.capitalize()}: {value} -> Register {address}")
else:
print(f"✗ {register_name.capitalize()}: Failed to write {value} -> Register {address} ({message})")
all_success = False

# Small delay between writes
time.sleep(0.1)

return all_success

def read_ecl_time(client, mb_id):
"""Read back the current Danfoss ECL time to verify the setting"""
try:
time_values = {}

for register_name, address in TIME_REGISTERS.items():
modbus_address = address - 1
response = client.read_holding_registers(address=modbus_address, count=1, slave=mb_id)

if isinstance(response, ExceptionResponse):
return None
else:
time_values[register_name] = response.registers[0]

# Convert 2-digit year to 4-digit year (assuming 20xx)
full_year = 2000 + time_values['year'] if time_values['year'] < 100 else time_values['year']

# Format as datetime string
return f"{full_year:04d}-{time_values['month']:02d}-{time_values['day']:02d} {time_values['hour']:02d}:{time_values['minute']:02d}"

except Exception as e:
return None

def main():
if len(sys.argv) > 1:
if sys.argv[1] in ['-h', '--help']:
print("Usage:")
print(" python3 set_time.py # Set to current system time")
print(" python3 set_time.py --help # Show this help")
print()
print("This script sets the Danfoss ECL controller's internal clock to the current system time.")
print("⚠️ WARNING: This will write to Modbus registers on the controller!")
return

print("=== Danfoss ECL Time Setting Tool ===")
print(f"Current system time: {datetime.now().strftime('%Y-%m-%d %H:%M:%S')}")
print()

client = ModbusSerialClient(
port=SERIAL_PORT,
baudrate=BAUD_RATE,
bytesize=DATA_BITS,
parity=PARITY,
stopbits=STOP_BITS,
timeout=2
)

try:
print(f"Connecting to Danfoss ECL on {SERIAL_PORT}")
print(f"Settings: Baudrate={BAUD_RATE}, Parity={PARITY}, ModBus ID={MB_ID}")
print()

if client.connect():
print("✓ Connection successful")
print()

# Small delay after connection
time.sleep(0.5)

# Read current ECL time
print("Reading current Danfoss ECL time...")
current_ecl_time = read_ecl_time(client, MB_ID)
if current_ecl_time:
print(f"Current Danfoss ECL time: {current_ecl_time}")
else:
print("Unable to read current Danfoss ECL time. Stopping.")
exit()
print()

# Set the time
success = set_ecl_time(client, MB_ID)
print()

if success:
print("✓ Time setting completed successfully")

# Read back to verify
time.sleep(0.5)
print("Verifying time setting...")
new_ecl_time = read_ecl_time(client, MB_ID)
if new_ecl_time:
print(f"✓ Danfoss ECL time is now: {new_ecl_time}")
else:
print("⚠ Unable to verify time setting")
else:
print("✗ Time setting failed - some registers could not be written")

else:
print("✗ Modbus connection failed")
print("Check serial port, wiring, and Danfoss ECL power")

except ModbusException as exc:
print(f"✗ Modbus Error: {exc}")
print("Check connections, port settings, and MB ID")
except Exception as exc:
print(f"✗ Unexpected error: {exc}")
finally:
if client.connected:
client.close()
print()
print("Serial port closed")

if __name__ == "__main__":
main()