β οΈ IMPORTANT: Single Modbus Connection Limit
Huawei inverters allow only ONE active Modbus TCP connection. This is a common beginner mistake when integrating Huawei solar systems into smart home environments.Before installing this add-on:
- β Disable or remove any other Huawei Solar integrations (official wlcrs/huawei_solar, HACS integrations, etc.)
- β Ensure no other software is accessing Modbus TCP (monitoring tools, apps, other Home Assistant instances)
- β Note: FusionSolar Cloud may show "Abnormal communication" when Modbus is active - this is expected
Running multiple Modbus connections simultaneously will cause connection timeouts and data loss for all clients!
Home Assistant Add-on for Huawei SUN2000 inverters via Modbus TCP β MQTT with Auto-Discovery.
Version 1.6.0 β 58 Essential Registers, 69+ entities, ~2β5 s cycle time
Changelog - CHANGELOG.md
- Modbus TCP β MQTT: 69+ entities with Auto-Discovery
- Complete Monitoring: Battery, PV (1-4), Grid (3-phase), Yield, Grid Power
- total_increasing Filter (NEW): Prevents false counter resets in Home Assistant energy statistics
- Performance: ~2-5s cycle, configurable (30-60s recommended)
- Error Tracking: Intelligent error aggregation with downtime tracking
- MQTT Stability: Connection wait loop and retry logic for reliable publishing
- Optimized Logging: Bashio log level synchronization with filter status indicators
- Cross-Platform: Supports all major architectures (aarch64, amd64, armhf, armv7, i386)
Both solutions use the same huawei-solar library but target different use cases:
wlcrs/huawei_solar (Native HA Integration):
- β Battery control (charge/discharge commands)
- β GUI configuration
- β Optimizer monitoring
- β RS485 serial support
This Add-on (MQTT Bridge):
- β MQTT-native (data accessible to Node-RED, Grafana, etc.)
- β total_increasing filter (protects energy statistics from false resets)
- β Advanced error tracking & performance monitoring
- β Fast 2-5s cycle times
- β Read-only monitoring
Important: Both share the same limitation - Huawei inverters allow only ONE Modbus connection. To use both simultaneously, you need a Modbus Proxy.
When to use which?
- wlcrs: Battery control + native HA integration
- This add-on: MQTT monitoring + external system integration
Diagnostic entities showing inverter status, temperature, and battery information
Complete sensor overview with real-time power, energy, and grid data
MQTT device integration details
- Install "Huawei Solar Modbus to MQTT" β Start
- Settings β Devices & Services β MQTT β "Huawei Solar Inverter"
Add-on configuration via Home Assistant UI with translated field names:
- Modbus Host: IP address of the Huawei Solar inverter (e.g.
192.168.1.100) - Modbus Port: Port for Modbus connection (default:
502) - Slave ID: Modbus Slave ID of the inverter (typically
1, sometimes16or0) - MQTT Broker: Hostname or IP address of the MQTT broker (e.g.
core-mosquitto) - MQTT Port: Port of the MQTT broker (default:
1883) - MQTT Username: Username for MQTT authentication (optional)
- MQTT Password: Password for MQTT authentication (optional)
- MQTT Topic: Base topic for MQTT messages (default:
huawei-solar) - Log Level: Verbosity level of logging (
DEBUG|INFO|WARNING|ERROR) - Status Timeout: Timeout in seconds for status checks (30-600, default:
180) - Poll Interval: Interval in seconds between Modbus polls (10-300, default:
30)
Auto-MQTT: Leave MQTT Broker, Username and Password empty β uses HA MQTT Service automatically
- Sensor Data (JSON):
huawei-solar(or your configured topic)
All sensor data as JSON object withlast_updatetimestamp. - Status (online/offline):
huawei-solar/status
Used for binary sensor,availability_topic, and last will testament.
Published to topic huawei-solar:
{
"power_active": 1609,
"power_input": 2620,
"battery_soc": 32,
"battery_power": 1020,
"meter_power_active": 50,
"voltage_grid_A": 239.3,
"inverter_temperature": 32.4,
"inverter_status": "On-grid",
"model_name": "SUN2000-6KTL-M1",
"last_update": 1768649491
...
..
.
}Complete example with all 58+ data points: examples/mqtt_payload.json
| Category | Sensors |
|---|---|
| Power | solar_power, input_power, grid_power, battery_power, pv1-4_power |
| Energy | daily_yield, total_yield, grid_exported/imported |
| Battery | battery_soc, charge/discharge_today, total_charge/discharge*, bus_voltage/current |
| Grid | voltage_phase_a/b/c, line_voltage_ab/bc/ca, frequency |
| Meter | meter_power_phase_a/b/c, meter_current_a/b/c, meter_reactive_power |
| Device | model_name, serial_number, efficiency, temperature, rated_power |
| Status | inverter_status, battery_status, meter_status |
* Sensors marked with asterisk are protected by total_increasing filter against false counter resets
total_increasing Filter: Prevents false counter resets in Home Assistant energy statistics
- Filters negative values and drops > 5% (configurable via
HUAWEI_FILTER_TOLERANCE) - Protects:
total_yield,grid_exported/imported,battery_total_charge/discharge - Automatic reset on connection errors
- Filter status visible in logs:
π Published - PV: 788W | AC Out: 211W | Grid: 11W | Battery: 569W π[2 filtered]
Bug Fixes:
- Fixed datetime serialization error for
startup_timeregister (now ISO format) - Improved Modbus exception handling to avoid BaseException errors
Enhanced Documentation: Extensive inline comments across all modules in German
Previous (1.5.1): Library version detection in startup logs
Previous (1.5.0): MQTT connection stability with wait-loop and retry logic
Previous (1.4.2): Repository maintenance and dependency fixes
Symptom: Connection timeouts, "No response received", intermittent data loss
Cause: Huawei inverters support only ONE active Modbus TCP connection
Solution:
- Check Settings β Devices & Services for other Huawei integrations
- Remove or disable:
- Official
wlcrs/huawei_solarintegration - Any HACS-based Huawei integrations
- Third-party monitoring software
- Official
- If using FusionSolar Cloud: Note that active Modbus may show "Abnormal communication" in the app - this is normal and expected
- Only ONE system can connect to Modbus at any time
No Connection: Enable Modbus TCP, verify IP/Slave-ID (try 1/16/0), set Log Level to DEBUG
Connection Timeouts: Try different Slave IDs (0, 1, 16); increase Poll Interval to 60s; check if FusionSolar Cloud is blocking Modbus access
MQTT Errors: Set MQTT Broker to core-mosquitto, leave credentials empty
Performance: Increase Poll Interval to 60s if cycle warnings appear
Filter Activity: Occasional filtering (1-2 per hour) is normal; frequent filtering indicates connection issues - enable DEBUG mode
Logs: Add-ons β Huawei Solar Modbus to MQTT β Log Tab
Found a bug or have a feature request? Please use our GitHub Issue Templates for structured reporting.