@@ -0,0 +1,173 @@
---
title: 'Reading Mbed Crash Logs over RS485 on Arduino Opta'
difficulty: advanced
description: "This tutorial explains how to read Mbed crash logs over RS485 on the Arduino Opta. By redirecting the crash logs to the RS485 bus, you can capture and analyze them using another Opta or an RS485 dongle."
tags:
- Opta
- RS485
- Mbed OS
- Debugging

author: 'Sebastian Romero'
hardware:
- hardware/07.opta/opta-family/opta
---

## Introduction

This tutorial shows how to redirect the Mbed crash log output (STDOUT) to the RS485 bus on the **Arduino Opta**.
This feature is available only when using the **Arduino Mbed Core** for Opta.

By default, crash logs and other Mbed debug messages are printed to the hardware serial port, which is not easily accessible on the Opta.
Redirecting STDOUT to RS485 provides a simple and reliable way to capture these logs using another Opta, an RS485 dongle, or an MKR 485 Shield.

---

## Hardware Required

- **Arduino Opta** (Mbed core)
- A second **Opta**, **RS485 USB dongle**, or **Arduino MKR 485 Shield** (for reading RS485 output)
- RS485 wiring (A/B lines)

---

## Circuit

Connect the RS485 lines as follows:

| Opta (sender) | Receiver (Opta / RS485 dongle / MKR 485 Shield) |
|----------------|-------------------------------------------------|
| A | A |
| B | B |
| GND | GND (recommended) |

---

## Example Code

Upload the following example sketch to your **Opta (sender)**:

```cpp
#include "RS485FileHandle.h"
REDIRECT_STDOUT_TO(&RS485Console) // Redirect Mbed crash log output to RS485

void setup() {
// Force a crash to demonstrate the crash log over RS485
volatile int* p = nullptr;
*p = 42; // Dereference null pointer to cause a crash
}

void loop() {
// Nothing to do here
}
```

Once uploaded, the Opta will crash on startup, and the crash log will be sent over the RS485 bus.

---

## Reading the RS485 Output

You can read the crash log output using:

- Another **Opta** running a simple RS485 receiver sketch
- An **RS485 USB dongle** connected to your computer
- An **Arduino MKR 485 Shield** attached to a compatible board

For example, with another Opta, you can run this minimal receiver sketch:

```cpp
#include <ArduinoRS485.h>

void setup() {
Serial.begin(115200);
RS485.begin(115200);
RS485.receive();
Serial.println("Listening for RS485 data...");
}

void loop() {
while (RS485.available()) {
Serial.write(RS485.read());
}
}
```

You should see the raw crash log appear on the serial monitor.

---

## Parsing the Crash Log

The crash log generated by Mbed OS is not human-readable by default. A typical output on the receiver might look like this:

```
+++ MbedOS Fault Handler +++
FaultType: HardFault
Context:
R0 : 00000000
R1 : 0000002A
R2 : 00000000
R3 : 00000000
...
PC : 08007E12
LR : 08006B5B
SP : 2001FFEC
PSR : 61000000
Fault: Null pointer dereference
+++ End Fault Handler +++
```

To interpret it, you can use the **Mbed crash log parser** available here:
[mbed-os-example-fault-handler/crash_log_parser.py](https://github.com/ARMmbed/mbed-os-example-fault-handler/blob/master/crash_log_parser.py)

### 1. Generate a `.map` file

You need to provide the parser with a **map file** from your compiled firmware.
You can generate it using the Arduino CLI:

```bash
arduino-cli compile demo.ino \
--fqbn arduino:mbed_opta:opta \
--board-options "target_core=cm7" \
--board-options "split=100_0" \
--build-path build \
--build-property compiler.cpp.extra_flags="-Og -Wl,-Map,output.map"
```

This produces an `output.map` file in the `build` directory.

### 2. Run the Crash Log Parser

Once you’ve captured the crash log over RS485 (for example, saved to a file named `crash.txt`), you can parse it as follows:

```bash
python3 crash_log_parser.py -m output.map -c crash.txt
```

You’ll get a human-readable report showing the stack trace, fault details, and memory addresses — for example:

```
Crash Info:
Crash location = demo.ino:7 (0x08001234)
Current thread = Id: 0x20001C80
Fault type = Hard Fault
Registers:
R0 = 0x00000000
R1 = 0x0000002A
R2 = 0x20001E40
```

In this example, it indicates that the crash occurred at line 7 in `demo.ino`, which corresponds to the null pointer dereference we introduced.

---

## Summary

Redirecting STDOUT to RS485 on the Arduino Opta allows you to:

- Access otherwise hidden **crash logs** and **debug messages**
- Use standard Mbed functionality for **fault analysis**
- Capture logs easily via **RS485-compatible tools**

This feature is particularly useful for diagnosing issues in field-deployed Opta systems where the serial port is inaccessible.