This PR changes the SCI_CLOCKF register configuration to match the data sheet recommendations (section 4.2, SCI_CLOCKF=0x8800).
Also defines for associated clock parameters (SCI_CLOCKF, SLOW_SCK, FAST_SCK) are added.
Effect on VS1053B operation of this PR: The CLKI frequency of VS1053B will be increased by 0.5xXTALI. This means slightly faster operation, faster SPI, but potentially more power consumption.
This is a backwards compatible change. No need to change sketches using this library.