- Write
0x100to handle0x22(UUID00002902-0000-1000-8000-00805f9b34fb) to start receiving records as values change - Write
0xbb9aa90ceeto handle0x25(UUID0000fff2-0000-1000-8000-00805f9b34fb) to trigger a once-off transfer of all parameter values
- Records are sent with a start byte of
0xbband an end byte of0xee. - Records can contain one or more parameter values.
- Format is
value byte 1 [... value byte N]followed by the parameter type. - Values are packed BCD, parameter types are in the range
0xb0to0xf0.
| ID | Paramater Name | Equation |
|---|---|---|
| b0 | Battery capacity | x / 10 |
| b1 | Over-temp protection (C) | x - 100 |
| b2 | ||
| b3 | ||
| b4 | ||
| b5 | ||
| b6 | ||
| b7 | Relay mode | 0 = N/O, 1=N/C |
| b8 | ||
| b9 | ||
| c0 | Volts | x / 100 |
| c1 | Amps | x / 100 |
| c2 | Protection delay sec | x = seconds |
| c3 | Protection recovery sec | x = seconds |
| c4 | ||
| c5 | Over-voltage protection | x / 100 |
| c6 | Under-voltage protection | x / 100 |
| c7 | Over-current protection | x / 100 |
| c8 | Over-current charge protection | x / 100 |
| c9 | Over-power protection | x / 100 |
| d0 | Relay state | 0=off, 1=on |
| d1 | Charge state | 0=Discharging, 1=Charging |
| d2 | Ah remaining | x / 1000 |
| d3 | KWh discharged | x / 100000 |
| d4 | KWh charged | x / 100000 |
| d5 | Total run time | x = seconds |
| d6 | Time remaining | x = minutes |
| d7 | Impedance | x / 100 |
| d8 | Watts | x / 100 |
| d9 | Temperature (C) | x - 100 |
| e0 | ||
| e1 | ||
| e2 | ||
| e3 | Under-temp protection | x - 100 |
| f0 |
State of charge is not a stored parameter, but is calculated with (d2 / 100) / b0
Record recieved:
bb 08 23 14 44 d5 09 99 99 d2 32 05 66 d3 24 ee
bb = start of record
08231444 = 1st param value
d5 = 1st param type (Total Run Time of 8231444 seconds, or ~95 days)
099999 = 2nd param value
d2 = 2nd param type (Ah remaining = 99999 / 1000, or 99.99 Ah)
320566 = 3rd param value
d3 = 3rd param type (KWh discharged = 320566 / 100000, or 3.20566)
24 = checksum byte
ee = end of record
-
Write
0x100to handle0x22(UUID00002902-0000-1000-8000-00805f9b34fb) to start receiving records as values change This will cause the device to start sending records to the notification handle0x2dwhenever a parameter value changes.
If there is no current flowing in or out of the battery, the only parameter that will be changing frequently isd5Total Run time, which will increment every second - and if the output relay is set to OFF, you may not see any traffic at all.
Many of the parameter values will never change without manual intervention (e.g. most of theb*and thec*configuration and protection settings) so these will not be visible without triggering a one-off dump of all parameter values. -
Write
0xbb9aa90ceeto handle0x25(UUID0000fff2-0000-1000-8000-00805f9b34fb) to trigger a once-off transfer of all parameter values
This will cause the device to immediately start sending all the (unordered) parameter values once to the notification handle0x2dif it is already sending notifications.
junctek.pl is a small Perl script that wraps gatttool to fetch all the parameter values from a Junctek battery monitor device once, and optionally publish them to an MQTT server.
(Note: gatttool has been deprecated for a while now and one day will disappear from distros)
Parameters can either be set in the configuration section at the start of the script, or supplied on the commandline. Commandline options override the script settings.
Usage: junctek.pl [OPTION?]
Options:
-d, --device=MAC Specify remote Bluetooth address
-q, --quiet Don't print output
-m, --mqtt Enable (1) or disable (0) publishing to MQTT
-s, --server Hostname of MQTT server
-u --username MQTT username
-p --password MQTT password
-n, --name 'Friendly' name of device, MQTT topic becomes junctek/[name]/...
-r, --retain Publish MQTT messages with retain flag
To publish to MQTT, you'll need the Net::MQTT::Simple Perl module installed.
If its not available as a native package for your distro, it can be installed from CPAN e.g.