4 changes: 0 additions & 4 deletions packages/control/chargelog/chargelog.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,11 +8,9 @@
from typing import Any, Dict, List, Optional, Tuple

from control import data
from dataclass_utils import asdict
from helpermodules.measurement_logging.process_log import (
FILE_ERRORS, CalculationType, _analyse_energy_source,
_process_entries, analyse_percentage, get_log_from_date_until_now, get_totals)
from helpermodules.pub import Pub
from helpermodules import timecheck
from helpermodules.utils.json_file_handler import write_and_check

Expand Down Expand Up @@ -116,7 +114,6 @@ def collect_data(chargepoint):
log_data.time_charged += now - log_data.timestamp_start_charging
log_data.timestamp_start_charging = None
log_data.end = now
Pub().pub(f"openWB/set/chargepoint/{chargepoint.num}/set/log", asdict(log_data))
except Exception:
log.exception("Fehler im Ladelog-Modul")

Expand Down Expand Up @@ -299,7 +296,6 @@ def calc_energy_costs(cp, create_log_entry: bool = False):
f"total charged_energy_by_source {cp.data.set.log.charged_energy_by_source}")
costs = _calc_costs(charged_energy_by_source, reference_entries[-1]["prices"])
cp.data.set.log.costs += costs
Pub().pub(f"openWB/set/chargepoint/{cp.num}/set/log", asdict(cp.data.set.log))


def calculate_charged_energy_by_source(cp, processed_entries, reference_entries, create_log_entry: bool = False):
Expand Down
86 changes: 19 additions & 67 deletions packages/control/chargepoint/chargepoint.py
Original file line number Diff line number Diff line change
Expand Up @@ -97,21 +97,6 @@ def _is_grid_protection_inactive(self) -> Tuple[bool, Optional[str]]:
message = "Ladepunkt gesperrt, da der Netzschutz aktiv ist."
return state, message

def _is_loadmanagement_available(self) -> Tuple[bool, Optional[str]]:
""" prüft, ob Lastmanagement verfügbar ist. Wenn keine Werte vom EVU-Zähler empfangen werden, darf nicht geladen
werden.
"""
if self.data.set.loadmanagement_available:
state = True
message = None
else:
state = False
message = ("Ladepunkt gesperrt, da keine Werte vom EVU- oder Zwischenzähler-Zähler empfangen wurden und "
"deshalb kein Lastmanagement durchgeführt werden kann. Bitte schaue auf der Status-Seite nach "
"Fehlermeldungen bei den Zählern. Falls Du dennoch laden möchtest, kannst Du als "
"Gerät 'Virtuelles Gerät' mit einer Komponente 'Virtueller Zähler' verwenden.")
return state, message

def _is_autolock_inactive(self) -> Tuple[bool, Optional[str]]:
""" prüft, ob Autolock nicht aktiv ist oder ob die Sperrung durch einen dem LP zugeordneten ID-Tag aufgehoben
werden kann.
Expand Down Expand Up @@ -149,17 +134,18 @@ def _is_manual_lock_inactive(self) -> Tuple[bool, Optional[str]]:
(self.data.get.vehicle_id is not None and fnmatch(self.data.get.vehicle_id, tag_id)) or
(self.data.set.rfid is not None and fnmatch(self.data.set.rfid, tag_id))):
match = True
if match:
Pub().pub(f"openWB/set/chargepoint/{self.num}/set/manual_lock", False)
elif self.template.data.disable_after_unplug and self.data.get.plug_state is False:
Pub().pub(f"openWB/set/chargepoint/{self.num}/set/manual_lock", True)

if self.data.set.manual_lock:
charging_possible = False
message = "Keine Ladung, da der Ladepunkt gesperrt ist."
else:
charging_possible = True
message = None

if match:
self.data.set.manual_lock = False
elif self.template.data.disable_after_unplug and self.data.get.plug_state is False:
self.data.set.manual_lock = True
return charging_possible, message

def _is_ev_plugged(self) -> Tuple[bool, Optional[str]]:
Expand All @@ -175,13 +161,11 @@ def is_charging_possible(self) -> Tuple[bool, Optional[str]]:
try:
charging_possible, message = self._is_grid_protection_inactive()
if charging_possible:
charging_possible, message = self._is_loadmanagement_available()
charging_possible, message = self._is_manual_lock_inactive()
if charging_possible:
charging_possible, message = self._is_manual_lock_inactive()
charging_possible, message = self._is_ev_plugged()
if charging_possible:
charging_possible, message = self._is_ev_plugged()
if charging_possible:
charging_possible, message = self._is_autolock_inactive()
charging_possible, message = self._is_autolock_inactive()
except Exception:
log.exception("Fehler in der Ladepunkt-Klasse von "+str(self.num))
return False, "Keine Ladung, da ein interner Fehler aufgetreten ist: "+traceback.format_exc()
Expand All @@ -198,36 +182,26 @@ def _process_charge_stop(self) -> None:
self.data.get.imported,
self.data.set.ocpp_transaction_id,
self.data.set.rfid)
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/ocpp_transaction_id", None)
self.data.set.ocpp_transaction_id = None
self.reset_control_parameter_at_charge_stop()
data.data.counter_all_data.get_evu_counter().reset_switch_on_off(self)
if self.data.get.plug_state is False and self.data.set.plug_state_prev is True:
chargelog.save_and_reset_data(self, data.data.ev_data["ev"+str(self.data.config.ev)])
self.data.control_parameter = control_parameter_factory()
if self.data.set.charge_template.data.load_default:
self.data.config.ev = 0
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/config/ev", 0)
if self.template.data.disable_after_unplug:
self.data.set.manual_lock = True
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/manual_lock", True)
log.debug("/set/manual_lock True")
if data.data.general_data.data.temporary_charge_templates_active:
self.update_charge_template(
data.data.ev_data["ev"+str(self.data.config.ev)].charge_template)
self.data.set.rfid = None
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/rfid", None)
self.data.set.plug_time = None
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/plug_time", None)
self.data.set.phases_to_use = self.data.get.phases_in_use
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/phases_to_use",
self.data.set.phases_to_use)
self.data.set.current = 0
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/current", 0)
self.data.set.energy_to_charge = 0
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/energy_to_charge", 0)

def setup_values_at_start(self):
self._reset_values_at_start()
self._set_values_at_start()

def set_control_parameter(self, submode: str):
Expand All @@ -253,24 +227,15 @@ def set_control_parameter(self, submode: str):
except Exception:
log.exception("Fehler im LP-Modul "+str(self.num))

def _reset_values_at_start(self):
self.data.set.loadmanagement_available = True

def _set_values_at_start(self):
if self.data.get.plug_state and self.data.set.plug_time is None:
self.data.set.plug_time = timecheck.create_timestamp()
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/plug_time",
self.data.set.plug_time)

def remember_previous_values(self):
self.data.set.charge_state_prev = self.data.get.charge_state
self.data.set.plug_state_prev = self.data.get.plug_state
self.data.set.current_prev = self.data.set.current
self.data.set.ev_prev = self.data.config.ev
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/charge_state_prev", self.data.set.charge_state_prev)
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/plug_state_prev", self.data.set.plug_state_prev)
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/current_prev", self.data.set.current_prev)
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/ev_prev", self.data.set.ev_prev)

def reset_log_data_chargemode_switch(self) -> None:
reset_log = Log()
Expand Down Expand Up @@ -423,8 +388,6 @@ def initiate_phase_switch(self):
self.data.set.log.imported_since_plugged == 0):
# Einmal muss die Anzahl der Phasen gesetzt werden.
if self.data.set.phases_to_use == 0:
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/phases_to_use",
self.data.control_parameter.phases)
self.data.set.phases_to_use = self.data.control_parameter.phases
if self.hw_supports_phase_switch():
if self._is_phase_switch_required():
Expand Down Expand Up @@ -456,8 +419,6 @@ def initiate_phase_switch(self):
self.data.control_parameter.timestamp_last_phase_switch = create_timestamp()
self.set_state_and_log(message)
if self.data.set.phases_to_use != self.data.control_parameter.phases:
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/phases_to_use",
self.data.control_parameter.phases)
self.data.set.phases_to_use = self.data.control_parameter.phases
self.data.control_parameter.state = ChargepointState.PERFORMING_PHASE_SWITCH
else:
Expand Down Expand Up @@ -742,8 +703,6 @@ def update(self, ev_list: Dict[str, Ev]) -> None:
self.num,
self.data.set.rfid or self.data.get.rfid or self.data.get.vehicle_id,
self.data.get.imported)
Pub().pub("openWB/set/chargepoint/"+str(self.num) +
"/set/ocpp_transaction_id", self.data.set.ocpp_transaction_id)
if self.data.get.plug_state and self.data.set.plug_state_prev is False:
self.data.control_parameter.timestamp_chargemode_changed = create_timestamp()
# SoC nach Anstecken aktualisieren
Expand Down Expand Up @@ -784,12 +743,12 @@ def _get_charging_ev(self, vehicle: int, ev_list: Dict[str, Ev]) -> Ev:
Pub().pub(f"openWB/set/vehicle/{charging_ev.num}/get/force_soc_update", True)
log.debug("SoC nach EV-Wechsel")
self.data.config.ev = vehicle
Pub().pub(f"openWB/set/chargepoint/{self.num}/config", dataclasses.asdict(self.data.config))
self.data.set.charging_ev_data = charging_ev
return charging_ev

def update_charge_template(self, charge_template: ChargeTemplate) -> None:
# Prüfen, ob ein temporäres Ladeprofil aktiv ist und dieses übernehmen
self.data.set.charge_template = charge_template
Pub().pub(f"openWB/set/chargepoint/{self.num}/set/charge_template",
dataclasses.asdict(charge_template.data))

Expand All @@ -804,24 +763,24 @@ def _pub_connected_vehicle(self, vehicle: Ev):
LP-Nummer
"""
try:
soc_obj = ConnectedSoc(
self.data.get.connected_vehicle.soc = ConnectedSoc(
range_charged=self.data.set.log.range_charged,
range_unit=data.data.general_data.data.range_unit,
)
if vehicle.soc_module is not None:
soc_obj.timestamp = vehicle.data.get.soc_timestamp
soc_obj.soc = vehicle.data.get.soc
soc_obj.fault_state = vehicle.data.get.fault_state
soc_obj.fault_str = vehicle.data.get.fault_str
soc_obj.range = vehicle.data.get.range
info_obj = ConnectedInfo(id=vehicle.num,
name=vehicle.data.name)
self.data.get.connected_vehicle.soc.timestamp = vehicle.data.get.soc_timestamp
self.data.get.connected_vehicle.soc.soc = vehicle.data.get.soc
self.data.get.connected_vehicle.soc.fault_state = vehicle.data.get.fault_state
self.data.get.connected_vehicle.soc.fault_str = vehicle.data.get.fault_str
self.data.get.connected_vehicle.soc.range = vehicle.data.get.range
self.data.get.connected_vehicle.info = ConnectedInfo(id=vehicle.num,
name=vehicle.data.name)
if (self.data.set.charge_template.data.chargemode.selected == "time_charging" or
self.data.set.charge_template.data.chargemode.selected == "scheduled_charging"):
current_plan = self.data.control_parameter.current_plan
else:
current_plan = None
config_obj = ConnectedConfig(
self.data.get.connected_vehicle.config = ConnectedConfig(
charge_template=self.data.set.charge_template.data.id,
ev_template=vehicle.ev_template.data.id,
chargemode=self.data.set.charge_template.data.chargemode.selected,
Expand All @@ -830,13 +789,6 @@ def _pub_connected_vehicle(self, vehicle: Ev):
average_consumption=vehicle.ev_template.data.average_consump,
time_charging_in_use=True if (self.data.control_parameter.submode ==
"time_charging") else False)
if soc_obj != self.data.get.connected_vehicle.soc:
Pub().pub(f"openWB/chargepoint/{self.num}/get/connected_vehicle/soc", dataclasses.asdict(soc_obj))
if info_obj != self.data.get.connected_vehicle.info:
Pub().pub(f"openWB/chargepoint/{self.num}/get/connected_vehicle/info", dataclasses.asdict(info_obj))
if config_obj != self.data.get.connected_vehicle.config:
Pub().pub(f"openWB/chargepoint/{self.num}/get/connected_vehicle/config",
dataclasses.asdict(config_obj))
except Exception:
log.exception("Fehler im Prepare-Modul")

Expand Down
41 changes: 21 additions & 20 deletions packages/control/chargepoint/chargepoint_data.py
Original file line number Diff line number Diff line change
Expand Up @@ -59,9 +59,11 @@ def connected_soc_factory() -> ConnectedSoc:

@dataclass
class ConnectedVehicle:
config: ConnectedConfig = field(default_factory=connected_config_factory)
info: ConnectedInfo = field(default_factory=connected_info_factory)
soc: ConnectedSoc = field(default_factory=connected_soc_factory)
config: ConnectedConfig = field(default_factory=connected_config_factory,
metadata={"topic": "get/connected_vehicle/config"})
info: ConnectedInfo = field(default_factory=connected_info_factory,
metadata={"topic": "get/connected_vehicle/info"})
soc: ConnectedSoc = field(default_factory=connected_soc_factory, metadata={"topic": "get/connected_vehicle/soc"})


def empty_enery_source_dict_factory():
Expand Down Expand Up @@ -148,25 +150,24 @@ def log_factory() -> Log:

@dataclass
class Set:
charge_template: ChargeTemplate = field(default_factory=charge_template_factory)
current: float = 0
energy_to_charge: float = 0
ev_prev: int = 0
loadmanagement_available: bool = True
log: Log = field(default_factory=log_factory)
manual_lock: bool = False
phases_to_use: int = 0
plug_state_prev: bool = False
plug_time: Optional[float] = None
required_power: float = 0
rfid: Optional[str] = None
charge_template: ChargeTemplate = field(default_factory=charge_template_factory,
metadata={"topic": "set/charge_template"})
current: float = field(default=0, metadata={"topic": "set/current"})
ev_prev: int = field(default=0, metadata={"topic": "set/ev_prev"})
log: Log = field(default_factory=log_factory, metadata={"topic": "set/log"})
manual_lock: bool = field(default=False, metadata={"topic": "set/manual_lock"})
phases_to_use: int = field(default=0, metadata={"topic": "set/phases_to_use"})
plug_state_prev: bool = field(default=False, metadata={"topic": "set/plug_state_prev"})
plug_time: Optional[float] = field(default=None, metadata={"topic": "set/plug_time"})
required_power: float = field(default=0, metadata={"topic": "set/required_power"})
rfid: Optional[str] = field(default=None, metadata={"topic": "set/rfid"})
# set current aus dem vorherigen Zyklus, um zu wissen, ob am Ende des Zyklus die Ladung freigegeben wird
# (für Control-Pilot-Unterbrechung)
current_prev: float = 0.0
target_current: float = 0 # Soll-Strom aus fest vorgegebener Stromstärke
current_prev: float = field(default=0.0, metadata={"topic": "set/current_prev"})
target_current: float = field(default=0, metadata={"topic": "set/target_current"})
charging_ev_data: Ev = field(default_factory=ev_factory)
ocpp_transaction_id: Optional[int] = None
charge_state_prev: bool = False
ocpp_transaction_id: Optional[int] = field(default=None, metadata={"topic": "set/ocpp_transaction_id"})
charge_state_prev: bool = field(default=False, metadata={"topic": "set/charge_state_prev"})


@dataclass
Expand Down Expand Up @@ -225,7 +226,7 @@ class ChargepointData:
control_parameter: ControlParameter = field(default_factory=control_parameter_factory)
get: Get = field(default_factory=get_factory)
set: Set = field(default_factory=set_factory)
config: Config = field(default_factory=config_factory)
config: Config = field(default_factory=config_factory, metadata={"topic": "config"})

def set_event(self, event: Optional[Event] = None) -> None:
self.event_update_state = event
Expand Down
4 changes: 0 additions & 4 deletions packages/control/chargepoint/rfid.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,4 @@
import logging
from dataclasses import asdict
from typing import Optional

from control import data
Expand Down Expand Up @@ -29,7 +28,6 @@ def _link_rfid_to_cp(self: ChargepointProtocol) -> None:
# keine Duo
cp2_data is None):
self.data.set.rfid = rfid
Pub().pub("openWB/chargepoint/"+str(self.num)+"/set/rfid", rfid)
self.chargepoint_module.clear_rfid()

self.data.get.rfid = None
Expand Down Expand Up @@ -65,10 +63,8 @@ def _validate_rfid(self) -> None:
self.data.get.rfid_timestamp = None
if self.template.data.disable_after_unplug:
self.data.set.manual_lock = True
Pub().pub("openWB/set/chargepoint/"+str(self.num)+"/set/manual_lock", True)
if self.data.set.charging_ev_data.charge_template.data.load_default:
self.data.config.ev = 0
Pub().pub(f"openWB/set/chargepoint/{self.num}/config", asdict(self.data.config))
Pub().pub(f"openWB/set/chargepoint/{self.num}/get/rfid_timestamp", None)
msg = ("Es ist in den letzten 5 Minuten kein EV angesteckt worden, dem "
f"der ID-Tag {rfid} zugeordnet werden kann. Daher wird dieser verworfen.")
Expand Down
1 change: 0 additions & 1 deletion packages/control/process.py
Original file line number Diff line number Diff line change
Expand Up @@ -139,7 +139,6 @@ def _update_state(self, chargepoint: chargepoint.Chargepoint) -> None:
current = 0

chargepoint.data.set.current = current
Pub().pub("openWB/set/chargepoint/"+str(chargepoint.num)+"/set/current", current)
log.info(f"LP{chargepoint.num}: set current {current} A, "
f"state {ChargepointState(chargepoint.data.control_parameter.state).name}")

Expand Down
Loading