Skip to content

Conversation

@svenn-t
Copy link
Contributor

@svenn-t svenn-t commented Dec 4, 2025

Simple 5x5x5 test cases for TPSA using lagged and fixed-stress coupling schemes to Flow.

See OPM/opm-simulators#6650 and OPM/opm-common#4846.

PR in draft mode, since both companion PRs are in draft mode.

@alfbr alfbr requested a review from totto82 December 4, 2025 12:54
@alfbr
Copy link
Member

alfbr commented Dec 4, 2025

From my end this looks fine, very much welcome a test case to accompany new functionality! Unfortunately, I am not familiar with the functionality in question, so assigned @totto82 at reviewer. Once he confirms that this is fine functionality wise, we merge.

@hnil
Copy link
Member

hnil commented Dec 22, 2025

The testcase runs, but give very little output, nothing in restart (i.e. for resinsight, and limited for paraview). Probably it would be good to add full settings of boundary conditions since it then would be easier to use it for setting up an other case.